Voltage Singularity-Based Diagnostic for PEM Fuel Cell Stack designed for Operation in ŒCHP Units

N/A
N/A
Protected

Academic year: 2021

Partager "Voltage Singularity-Based Diagnostic for PEM Fuel Cell Stack designed for Operation in ŒCHP Units"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-01830711

https://hal.archives-ouvertes.fr/hal-01830711

Submitted on 5 Jul 2018

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci-entific research documents, whether they are pub-lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Voltage Singularity-Based Diagnostic for PEM Fuel Cell

Stack designed for Operation in ŒCHP Units

Djedjiga Benouioua, Denis Candusso, Fabien Harel, Pierre Picard

To cite this version:

Djedjiga Benouioua, Denis Candusso, Fabien Harel, Pierre Picard. Voltage Singularity-Based Diag-nostic for PEM Fuel Cell Stack designed for Operation in ŒCHP Units. CDFC 2017, 7th International Conference on Fundamentals & Development of Fuel Cells„ Jan 2017, STUTTGART, Germany. 1 p. �hal-01830711�

(2)

Voltage Singularity-Based Diagnostic for PEM Fuel Cell Stack designed for Operation in µCHP Units

D. Benouioua1,2,4, D. Candusso1,2,4, F. Harel3,4, and P. Picard1,5

1 ITE EFFICACITY, 14-20 boulevard Newton, Champs-sur-Marne, F-77447 Marne la Vallée, France. 2 IFSTTAR / COSYS / SATIE, UMR CNRS 8029, 25 allée des marronniers, F-78000 Versailles Satory, France. 3 Université de Lyon, IFSTTAR / AME / LTE, 25 avenue François Mitterrand, Case24, F-69675 Bron Cedex, France.

4 FCLAB, FR CNRS 3539, Rue Ernest Thierry Mieg, F-90010 Belfort Cedex, France. 5 ENGIE, La Plaine Saint-Denis, France.

A non-intrusive and without disturbance diagnostic strategy for a low temperature Proton Exchange Membrane Fuel Cell (PEMFC) designed to operate in µCHP units is proposed. The developed diagnosis strategy consists of two phases:

 In the first phase, an experimental campaign is conducted on a 12 cell PEMFC stack dedicated to stationary application. It is designed and marketed by Riesaer Brennstoffzellentechnik GmbH and Inhouse Engineering GmbH, Germany. Thereby, a database is built; it includes many physical signals measured from the stack and the testbench ancilliaries such as: gas pressures, flows, temperatures… and the voltage stack signal recorded with a sampling frequency of 3kHz for nominal and faulty operating conditions.

 In the second phase, the research of relevant indicators for the PEMFC State-of-Helath (SoH) is made by analyzing the stamped singularities in the stack voltage signal according to the various operating conditions.

The approved approach implements two data analysis steps:

o A data pre-processing step based on the filtering of a voltage signal (acquired during 1 hour) to achieve the separating of its low and high frequencies components. Then, a Useful Voltage (UV) signal was obtained by computing the Root Mean Square ‘RMS’ on the windowed filtered voltage signal (with a window size of 0.066 s).

o A data processing step that consists of computing a punctual singularity strength in the UV signals and summarizing all the founded singularities strength in the form of a singularity spectrum (SS). The signal processing method adopted in this study, namely the Wavelet Leaders-Based Multifractal Analysis (WLMA), has been published in previous works [1, 2] and showed high-performance results on a PEMFC designed for transport application.

The results of the SS features classification enable the identification of a wide range of operating failures for the studied PEMFC stack dedicated to µCHP application.

References:

[1] D. Benouioua, D. Candusso, F. Harel and L. Okhellou, Fuel Cells Vol. (?), 1-8 (2016).

Références

Documents relatifs

If we look at regu- lar foliations (i.e. leaves are manifolds) on a singular space, then everything works except that the ´etale holonomy groupoid is now a singular Lie groupoid and

The studied FC operating conditions are: Ref: normal conditions - DFSC: cathode flow fault (slight air starvation) - DFSA: anode flow fault (slight H 2 starvation) - DP: gas

Fault diagnosis of practical polymer electrolyte membrane (PEM) fuel cell system with data-driven approaches. Data-driven diagnosis of PEM fuel cell: A comparative

The effects of varying the parameters of the hot-pressing technique are shown in Figure 1 c), the OCP obtained MEA- OKUR is 1.008 V and the MEA-EROSA is 0.98 V, a higher OCP is

LWIM - Low Power Wireless Integrated Microsensors - Bill Kaiser UCLA Smart Dust proposal written, Kris Pister Berkeley Seth Hollar makes wireless mouse collars Endeavour

For each selected sub-model, it is possible to construct a consistency relation involving one fault and therefore derive from it a residual sensitive to that fault.. This

b) Listing valid configurations of circles: Experimen- tally, we observe that only fuses that belong to a circle can be uncertain. Moreover, circles can be considered as