Abstract : Detecting the cracks is a major challenge in the development of Eddy Current (EC) Non-Destructive Testing (NDT). In fact, the detection sensitivity of EC-NDT depends on the interaction between the crack characteristics and the EC formed in the materials. The induced currents are primarily generated along a single direction in the tested sample. This paper presents a excitation method for generating a ac magnetic field and, consequently, eddy currents. This method significantly improves the detection of cracks of two different kind of material (non magnetic conductive material and ferromagnetic material). The magnetic flux density signature of the defect is studied using a 2D Finite Element Model FEM.

Keywords : Eddy Current, Non-Destructive testing, Giant Magneto Resistance, Finite Element Method

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

Dans cet article seront présentées une méthode électrique, où l'échantillon est en contact avec le système de mesure on parle alors de méthode directe, et

Its use in detection of the defects, particularly in the determination of corrosions .The contained information in the received signal makes it possible to determine

We have used a 2D numerical model based on the Finite Element Method (FEM) to simulate the NDT inspection process and to predict the corresponding signal sensed by the GMR

respectively represent the working range of case n (highly conducting medium and high frequency operation) and case n 2 (test material with high magnetic properties and low

The light is modulated by M I at the frequency w l , the optical focus is a point source from which a thermal wave propagates to arrive at the rear surface where it is

Transférinémie : valeur pronostique préopératoire chez les sujets porteurs d'un cancer de l'œsophage symposium sur les marqueurs de l'inflammation; le profil protéique dans

2 or 3 dimensional (depending on the dimension of the test sample) finite differences space discretization is used for the resolution of the diffusion equation and dynamic

Abstract—This paper presents a design optimization of an axial-field eddy-current magnetic coupling. The design procedure is based on a torque formula derived from a 3-D