079 Poster - Modulators in radiation therapy Improvement of radiation efficacy for brain cancer F98 glioma by adding concomitant platinum compounds

G. Charest, L. Sanche, D. Fortin and B. Paquette

Universit´e de Sherbrooke, 3001, 12e Avenue Nord, QC J1H 5N4 Sherbrooke, Canada gabriel.charest@usherbrooke.ca

Background: Free platinum formulation: cisplatin, carboplatin and oxaliplatin as well as their liposomal formulation (Lipoplatin for cisplatin and Lipoxal for oxali- platin) are largely used as cytotoxic agents in the treatment of many tumor types.

However, free platinum formulation are known to cause sever adverse reactions.

In treatment against glioblastoma multiform, the development of an aggressive but selective therapy is needed. In this project, we tested different platinum com- pounds to identify which one shows the best synergy with radiation. Material and methods: The cytotoxicity of platinum compounds against F98 glioma cell line was assessed by colony formation assay. Cell uptake for the same cell line and platinum was measured by Induced coupled plasma mass spectrometer. After four hours exposure to platinum, cells were irradiated (1.5 to 6.6 Gy) with a 60Co source. Results: The relative cytotoxcicity induced by the five platinum formula- tions was oxaliplatin >Lipoxal> cisplatin>Lipoplatin >carboplatin. On the other hand, when F98 cell line incubated with platinum were irradiated, the com- bination index calculated and the relative potency were Lipoplatin>carboplatin

>oxaliplatin>Lipoxal>cisplatin. Conclusions: In the present work, Lipoplatin shows the best cytotoxic combination with radiation to treat F98 cell line in vitro.

278 RADIOPROTECTION - VOL. 43 - N5 (2008)

Article published by EDP Sciences and available at http://www.radioprotection.org or http://dx.doi.org/10.1051/radiopro:2008583

Références

Documents relatifs

Si l’on rapproche ce chiffre des 10000 joules mentionnées plus haut, on voit qu’en régime stationnaire, l’augmentation d’un facteur 1 0 de la concentration d’un

This paper intends to m e s s the scope of the problem and to review recent data reported on exposure which may occur in different workplaces due to natural sources:

Par des frottis, prélevés après ce nettoyage, on estima l’activité, moyennée sur la masse totale des échangeurs, à environ 3 Bq/g pour les alphas et à 12 Bq/g pour

À l’aide de cette expression, il est aisé de déterminer le seuil de détection du bore, en observant qu’au microscope optique il a été constaté qu’une densité de traces

On peut envisager d’autres configurations de dosimétrie fermés, basées sur le LR115, qui conservent les avantages de la détection ouverte (en particulier ON/OFF) tout

Nous commençons à recevoir les premières réponses à notre questionnaire sur la revue, elles sont plutôt positives, mais leur nombre ne nous permet pas encore d’en tirer

FOCON96 calcule la dispersion des gaz et des aérosols dans l’environnement (contamination de l’air et dépôt au sol), leur transfert dans la biosphère (sols, végétaux et

Ceci nous le devons en premier lieu aux auteurs que j e tiens à remercier ici pour leur confiance dans notre revue, mais nous le devons aussi à nos évaluateurs