• Aucun résultat trouvé

Study of the resilience of a compositematerialintended for the orthopedic prosthesis ofa tibia

N/A
N/A
Protected

Academic year: 2021

Partager "Study of the resilience of a compositematerialintended for the orthopedic prosthesis ofa tibia"

Copied!
1
0
0

Texte intégral

(1)

23ème Congrès Français de Mécanique 2017

Study of the resilience of a composite

materialintended for the orthopedic prosthesis of a tibia

N. Sassane, K.Boubendira, A.BENFOUGHAL, N.BOUGHEDIR, N.HAMZAOUI

Abstract : This approach is based on the mechanical characterization of a biomaterial which is an organiccomposite with a thermosetting polymer matrix reinforced with a glass fiber; this composite has beenproduced by a conventional casting method.

Currently, composite polymer-matrix objects occupy animportant place in the aeronautics, automotive, medical industry etc……, for this purpose, we areinterested in the study of a mechanical property of a thermosetting polymer matrix compositereinforced with glass fiber, this composite is intended for the orthopedic prosthesis of a tibia, thisproperty called resilience. For so doing, we have realized a Charpy shock test on a sample of thepolymer matrix composite reinforced with a glass fiber for the orthopedic prosthesis of a tibia. Wehave also supported this study by a hardness test and microscopic characterization (SEM) to revealthe microstructure of the composite.

Keywords : composite – mechanical property – resilience –hardness – microstructure

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

Index Terms—Harmonic Maxwell Equations; Electromag- netism; Homogenization; Asymptotic Analysis; Asymptotic Ex- pansion; Two-scale Convergence; Frequencies; Composite Ma- terial..

The values of the magnetic field applied in the X direction of the photomultiplier corresponding to 10% and 20% signal reduction as function of the high voltage applied on

The research approach used in this research fits into the type 2 case study (study of several units of analysis in one case) according to Yin (1994) classification. In

The experimental mechanical behavior curves obtained are linear elastic with different slopes denoting a slight variation of flexural modulus of elasticity of the test pieces tested.

Abstract: In orthopedic surgery, the effectiveness of the implants used, such as hip and knee prostheses, depends mainly on their geometries and the type of loading to which they

KEYWORDS— Reliability analysis, critical stress intensity factor, crack length, load, reliability index..

This study allowed us to study the evolution of the parameters to deduct by the test of impact Charpy as a function of temperature for a composite material intended for the

This papers based on an empirical case study elaborates on the question: can we see better with the help of an articulation of safety engineering, safety management and social