• Aucun résultat trouvé

A Fuzzy Logic Based Approach for themonitoringof Open Switch Fault in a SVMVoltage SourceInverter fed Induction MotorDrive

N/A
N/A
Protected

Academic year: 2021

Partager "A Fuzzy Logic Based Approach for themonitoringof Open Switch Fault in a SVMVoltage SourceInverter fed Induction MotorDrive"

Copied!
1
0
0

Texte intégral

(1)

J. Automation & Systems Engineering

Volume 12, Issue 2, 2018, Pages 48-66

A Fuzzy Logic Based Approach for the monitoringof Open Switch Fault in a SVM Voltage SourceInverter fed Induction Motor

Drive

Hichem MERABET, Tahar Bahi, Khouloud BEDOUD, Djalel DRICI

Abstract: The reliability of power electronics system such as three phase inverter is important in many industrial processes. The monitoring in industrial systems represents an important economic objective. To guarantee the safety and the continuity in production, exploitation and to record the useful events with the feedback experience for the curative maintenance. One of the possible faults that occur in inverter is the open switch fault. The cost of this schedule can be high, and this justifies the development of fault diagnostic methods.In this work we present a reliable strategy for monitoring and detection of open switch in Space Vector Modulation of voltage source inverter (SVM-VSI) faults using the fuzzy logic approach. The principle of the suggested approach strategy is based on the acquisition of stator currents, to calculate the average absolute values of currents (AAVC), which allows the real-time detection and localization of inverter IGBT open-circuit faults using just the motor phase currents. A model of the system is built using MATLAB/SIMULINK. Simulation results are presented showing the monitoring approach performance under distinct operating conditions.

Keywords : Monitoring, Detection, fault inverter, SVM, VSI, AAVC

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

The pro- posed model covers 2 dimensions, of which four aspects will be represented in order to evaluate the quality of the linked open data, which will help to show the capacity

Further, Michel de Certeau (1990), by acknowledging the possibility for the individual not to execute the action as it is expected, is able to focus on the “manières de

This processing includes: syntactical analysis of sentences using the constraint grammar Palavras [3]; semantical analysis using discourse representation theory [5]; and,

Section II presents demodulation techniques used for stator currents processing and section III focuses on the performance of these techniques on simulated data

Our approach includes leverag- ing Block-Based Programming Languages to incorporate Software Engineering practices for a metric collection effort that delivers value for the

Comparing with conventional fault diagnosis methods of inverter fed induction machine, in our work we are presented a reliable strategy for monitoring, detection and localization

The principle adopted for the strategysuggested is based on monitoring of the average root meansquare (RMS) value of the stator current, which will beuseful as input data with the

Agarawal , “ Fault Diagnosis of Three Phase Induction Motor using Fuzzy Logic Controller and Sequence Analyzer”, MIT International Journal of Electrical and