• Aucun résultat trouvé

Multimodal functional evaluation of severe kinking of an ascending aortic prosthesis in a patient with embolic stroke

N/A
N/A
Protected

Academic year: 2021

Partager "Multimodal functional evaluation of severe kinking of an ascending aortic prosthesis in a patient with embolic stroke"

Copied!
1
0
0

Texte intégral

(1)

CARDIOVASCULAR FLASHLIGHT

. . . .

doi:10.1093/eurheartj/ehu008

Online publish-ahead-of-print 3 February 2014

Multimodal functional evaluation of severe kinking of an ascending aortic

prosthesis in a patient with embolic stroke

Alexander Gotschy1,2, Christian Binter2, Markus Niemann1,2, Hatem Alkadhi3, Veronika Kana4, Martin Czerny5,

Felix C. Tanner1, Sebastian Kozerke2, and Robert Manka1,2,3*

1

Department of Cardiology, University Heart Center, University Hospital Zurich, Raemistrasse 100, Zurich 8091, Switzerland;2

Institute for Biomedical Engineering, University

and ETH Zurich, Gloriastrasse 35, Zurich 8092, Switzerland;3

Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, Zurich 8091,

Switzerland;4

Department of Neurology, University Hospital Zurich, Frauenklinikstrasse 26, Zurich 8091, Switzerland; and5

Clinic of Cardiac and Vascular Surgery, University Heart Center, University Hospital Zurich, Raemistrasse 100, Zurich 8091, Switzerland

*Corresponding author. Tel:+41 0442551251, Fax: +41 0442554401, Email:robert.manka@usz.ch

A 59-year-old male presented to the emergency department of our hospital. The patient had been in his usual health until a sudden 30 s episode of expressive aphasia, weakness of the right arm, and paraesthesia of the right hand oc-curred. Three years before admission the patient had received replacement of the ascending aorta with partial arch replacement due to an ascending aortic aneurysm. On presentation, neurological examinations were unremarkable. Magnetic res-onance imaging (MRI) of the head, however, showed a small lesion in the left primary motor cortex, suggestive of acute infarction.

Vascular ultrasound of the carotid arteries revealed only minimal atherosclerosis; 48-h holter monitoring was normal. A transthoracic echocardiography showed normal LV function and no evidence of patent foramen ovale. Com-puted tomography of the thorax (Panel A) found a septal structure in the ascending aorta that was confirmed by transoesophageal echocardiog-raphy (Panel B) and was interpreted as kinking of the aortic prosthesis.

Cardiovascular MRI was performed for further evaluation. MR-angiography of the aorta revealed a proximal twist and adjacent double kinking of the graft (Panels C – E, Supplementary material online, Movie S1). Flow-sensitive 4D-MRI was used to derive information on the haemodynamics inside the prosthesis. Three-dimensional pathline visual-ization (GyroTools, Switzerland) showed

pro-nounced flow disturbance with formation of vortices and helical flow (HF) (Panel F, Supplementary material online, Movie S2). The first vortex (V1) in front of the proximal kink exhibits low flow velocities, implying thrombogenic potential (Panel G: flow vector field). Between the two kinks, enhanced systolic peak flow (Vmax¼ 1.5 m/s) from the first stenosis hits a HF pattern that directs pathlines to

the supra-aortic vessels. A second vortex (V2) is located behind the distal kink.

Kinking of an aortic prosthesis causes unphysiological flow patterns and pressure gradients with the potential risk of thrombus formation and subsequent systemic embolism. Since aortic prostheses show a tendency to grow after implantation, graft-expansion is a potential cause for the formation of kinking folds. Repeat surgery would be indicated in cases of severe pressure gradients over the kinks, which was not present in our patient. As there are no data out on this particular issue, anti-aggregatory or anti-coagulatory strategies remain empiric. In our patient, treatment with clopidogrel was initiated and short-term outpatient follow-up was scheduled.

Supplementary material is available at European Heart Journal online.

This paper was guest edited by Brahmajee Nallamothu (bnallamo@umich.edu, University of Michigan).

Published on behalf of the European Society of Cardiology. All rights reserved.&The Author 2014. For permissions please email: journals.permissions@oup.com

Cardiovascular flashlight

Références

Documents relatifs

Correspondence to: Rolf Weidenhagen, Department of Surgery, Klinikum Grosshadern, Ludwig-Maximilian- University Munich, Marchioninistrasse 15, D-81377

transcatheter aortic valve implantation TAVI and that early discharge is feasible and safe in.. Aims: To evaluate length of stay LOS and reasons of prolonged hospitalization

Ein Monopol sei eine Beschränkung sowohl der Niederlassungs- als auch der Dienstleistungsfreiheit, und die vorliegende Fallgestaltung (wo es um die Ausstellung von Gutscheinen für

7—Competition between regular h100i and twinned h110i den- drites in a quenched Al-26 wt pct Zn specimen: (1) Twinned dendrite overgrown by an equiaxed grain nucleated ahead of

Après le souper, les jours sans pluie, on s’asseyait dans le jardin pour écouter le rossignol. Sans dire un mot, l’enfant sortit son cahier de

Prevalence of hepatitis and HIV infections and vaccination rates in patients entering the heroin-assisted treatment in Switzerland between 1994 and 2002 Miriam Gerlich 1,2 ,

Quand il sera cinq heures de l’après-midi combien de fois la grande aiguille sera-t-elle passée au- dessus de la petite aiguille.. Elle passera

RI WKH bel-1 JHQH FDVVHWWH ZDV DQDO\]HG LQ SK\VLRORJLFDO FRQGLWLRQV DQG ZLWK WKH LQWHJUDVH. JHQH EHLQJ RYHUH[SUHVVHG &DVVHWWH PRELOLW\ LQ Escherichia coli