• Aucun résultat trouvé

Sampling at t

N/A
N/A
Protected

Academic year: 2021

Partager "Sampling at t"

Copied!
1
0
0

Texte intégral

(1)

Sampling at t

i

Coconut

water

30°C

T pH O

2

Cond.

NIRS Water circulation

Feeding at t0

Data logger

NIRS spectra were continuously acquired with a LabSpec®Pro spectrophotometer in transmittance mode.

Figures 2a & 2b: Evolution of dissolved O2

, Titrable Acidity (TA) and pH of coconut water (7 and 9 months old) during storage at 30°C

under atmospheric pressure

Near Infrared Spectroscopy (NIRS):

a tool for on-line monitoring of beverage quality

PRADES Alexia 1 , ASSA Rebecca Rachel 2 , DORNIER Manuel 1 , PAIN Jean-Pierre 3

Coconut water (CW) is a tropical drink known for its refreshing and isotonic properties 1 . It is a fragile liquid subjected to rapid deterioration 2 . As a consequence, assessing its quality during processing and storage still remains a challenge.

Material and Methods Material and Methods

Results and discussion Results and discussion

Immature coconut fruits (Guinea Equatorial Green Dwarf variety from Côte d’Ivoire) were harvested at two grades of maturity (7 and 9 months old).

Aseptically collected CW was homogenised and stored into a 2 litres glass reactor (Fig1). The liquid temperature was maintained at 30±0.5°C using a double jacket water circulation. Data processing was performed using descriptive statistics and principal component analysis (PCA) with The Unscrambler ® (Camo Process AS., Norway).

Conclusion and perspectives Conclusion and perspectives

1

CIRAD, UMR Qualisud, 73 rue JF Breton, Montpellier, F-34398 France.

2

CNRA, Programme Cocotier, 07 BP 13 Abidjan 07, Côte d’Ivoire.

3

UM2, UMR Qualisud, Place E. Bataillon, Montpellier, F-34095 France CONTACT: alexia.prades@cirad.fr

The monitoring of physicochemical parameters showed that CW deterioration encountered at least four stages for both grades of maturity:

(I) a first stage where dissolved O 2 increased by 3 mgL -1 whereas pH and TA showed a slight decrease,

(II) a second stable stage,

(III) a third stage where dissolved O 2 fall down to 0 mgL -1 whereas TA began to rise,

(IV) a fourth stage where pH and TA showed clear antagonistic trends,

(V) a fifth stage (observed only on 9 months old nuts) where pH tend to stabilize around 3.8 and TA rose until 15 g citric acid.L -1 .

The previous stages were highlighted by PCA performed on physicochemical and NIR spectral data.

The first two principal components of the PCA performed on physicochemical data of the 7 and 9 months old CW (Fig. 3a and 4a) explained respectively 75% and 73% of the total variance.

However those from PCA performed on spectral data explained 96% and 99% (Fig. 3b and 4b).

References

1

Rethinam P. and Kumar T. B. N. (2001). Tender coconut - an overview. Indian Coconut Journal 32(1): 2-22.

2

Matsui K. N., Granado L. M., de Oliveira P.V., Tadini C.C (2007). Peroxidase and polyphenol oxidase thermal inactivation by microwaves in green coconut water simulated solutions. LWT - Food Science and Technology 40(5): 852-859.

3

Davrieux F., Prades A. et al. (2005). Physico-chemical changes in the fruits of two coconut(Cocos nucifera L.) hybrids during ripening : A NIRS-boosted study. In: FRUTIC 05, 7th Fruit, nut and vegetable production engineering Symposium:

Information and technology for sustainable fruit and vegetable production , Montpellier, France, 12-16 September 2005.

Figure 1:

Experimental setup

Soluble solids, titrable acidity (TA), turbidity and polyphenoloxidase activity were measured every 30 minutes. Microbiological analyses were regularly done between initial and final time.

Temperature, pH, dissolved O

2

and electrical conductivity were on-line recorded every 30 minutes during 48 hours.

www.cirad.fr

The potential of NIRS for on-line monitoring of coconut water quality was demonstrated : 1 NIRS “fingerprint” is equivalent to 7 measurements of physicochemical parameters

Further chemometric analyses and experiments may correlate spectral and chemical data to predict CW quality during storage

Among other food quality control methods, Near Infrared Spectroscopy (NIRS), a simple and non destructive analytical tool, should be a good challenger 3 . This study set out to determine if NIRS could monitor coconut water quality during storage at tropical ambient temperature.

0 1 2 3 4 5 6 7 8 9 10

0 3 6 912 15 18 21 24 27 30 33 36 39 42 45 48 Time (h)

Dissolved O2 and Titrable Acidity

3.0 3.5 4.0 4.5 5.0 5.5 6.0

pH

Dissolved O2 (mg/L) Titrable Acidity (g citric aci/L) pH

I II III IV V

2a: 7 months old coconut water

2b: 9 months old coconut water

0 1 2 3 4 5 6 7 8 9 10

0 3 6 9 12 15 18 21 24 27

Time (h) Dissolved O2 and Titrable Acidity

4.0 4.5 5.0 5.5 6.0

pH

Dissolved O2 (mg/L) Titrable Acidity (g. citric acid/L) pH

I II III IV

Microbiological analyses confirmed the sterility of CW at initial time and later showed the prevalence of bacteria (over yeasts and moulds) due to environmental contamination.

Stages I & II

Stage III

Stage IV Stage V

94

% 5%

Stages I & II

Stage IV Stage V

42%

31%

Part of Stage III Stages III & IV

Stage IIb Stage IIa

80%

Stage I 16%

Stages I and II Stage III

Stage IV

45%

39%

Fig 3a : PCA on physicochemical data

Fig 3b : PCA on NIRS data

Fig 4a : PCA on physicochemical data

Fig 4b: PCA on NIRS data

For 7 months old coconut water, PCA performed on NIR spectral data distinguished two phases during Stage II (Fig 3b) suggesting that NIRS monitoring was more sensitive than physicochemical monitoring.

For 9 months old coconut water, although Stages I and II were not separated (Fig 4b), other stages were more clearly identified by spectral than by physicochemical monitoring.

Main changes occurred during the first day (0 to 21hours) and especially during the first 10 hours of CW storage.

Références

Documents relatifs

More specifically, we address the problem of exchanging information given by representation systems, which are essentially finite descriptions of (possibly infinite) sets of

We present LENA, a web-based RDF browser that sup- ports the rendering of complex RDF data, including in- terlinked data available on the Semantic Web, based on criteria expressed

But non locality is also visible when, for systems made of two particles located in remote regions of space, one writes the components of the two particle states of the type

Near infrared spectroscopy was used to assess total soluble sugar (TSS) and lipid contents in the freeze-dried kernel of coconuts from two cultivars: PB121 or MYD x WAT from

While the regret bound and runtime of vanilla implementations of PSRL and UCRL2 are exponential in the number of bandits, we show that the episodic regret of MB- PSRL and MB-UCRL2 is

This paper presents a data race detection method that provides a detection rate for each memory location that has inverse relationship with access frequency, and adds less time and

Abstract: In this paper, we present a new process monitoring approach for uncertain, or highly noisy systems, which is based on the well known Moving Window Principal Component

A previous interview study with data professionals across a wide range of domains and skill sets [5] suggests that, in the majority of cases, searching for data shows characteristics