• Aucun résultat trouvé

Performance evaluation of photovoltaic arrays subject to a Line-Ground fault

N/A
N/A
Protected

Academic year: 2021

Partager "Performance evaluation of photovoltaic arrays subject to a Line-Ground fault"

Copied!
1
0
0

Texte intégral

(1)

3rd International Conference on Systems and Control (ICSC) 2013

Performance evaluation of photovoltaic arrays subject to a Line-Ground fault

N. BOUTASSETA, M. RAMDANI, S. AOUABDI

Abstract : In this work, the effect of Line-to-Ground fault on the performance of photovoltaic (PV) arrays is analyzed. Due to the nature of their outdoor operation, PV arrays are subject to extreme weather conditions that affect their normal operation. The exposure of cables and junction boxes to such environmental conditions leads to different types of connection faults. Given that the frame of the PV panel is metallic, a short-circuit between the Line (positive charged wire) and the ground may occur frequently. A particle swarm optimization (PSO) based maximum power point tracking (MPPT) algorithm is then used to improve the efficiency of PV arrays. Simulation results show the large power loss caused by such type of fault and the effectiveness of the proposed approach in increasing the system's efficiency.

Keywords : Photovoltaic (PV) arrays, Line-Ground fault, Particle Swarm Optimization (PSO), Maximum Power Point Tracking (MPPT)

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

A Novel Distributed Particle Swarm Optimization Algorithm for the Optimal Power Flow ProblemN. Nicolo Gionfra, Guillaume Sandou, Houria Siguerdidjane, Philippe Loevenbruck,

In addition, in this method the measurement of the SCC (I SC ) is frequently required which means shorting the module on each occasion. However, by using several loads this issue

The duty cycle (D) used in Pulse With modulation (PWM) to reproduced control switch for the boost converter by the maximum power point tracking (MPPT) for a photovoltaic (PV)

Keywords : Fault-tolerant control (FTC), Particle swarm optimisation (PSO), Photovoltaic (PV) arrays, Line-Ground fault, Line-line fault, Partial shading, Maximum Power Point

The application of the PSO method to adjust parameters of deep neural networks used for the machine learning process would be based on the fact that the PSO algo- rithm would

Youn, “New maximum power point tracker using sliding-mode observer for estimation of solar array current in grid- connected photovoltaic system, ” IEEE Transaction

The proposed technique uses the fuzzy logic control to specify the size of incremental current in the current command of MPPT.. As results indicated, the convergence

Moreover, given the variable nature of the power delivered by the photovoltaic panel, a tracking command of the maximum power point developing an optimal duty