• Aucun résultat trouvé

Impact of air leakage on hygrothermal and energy performance of buildings in North America. Part III: energy rating of insulated wall assemblies

N/A
N/A
Protected

Academic year: 2021

Partager "Impact of air leakage on hygrothermal and energy performance of buildings in North America. Part III: energy rating of insulated wall assemblies"

Copied!
49
0
0

Texte intégral

(1)

Vous avez des questions? Nous pouvons vous aider. Pour communiquer directement avec un auteur, consultez la

première page de la revue dans laquelle son article a été publié afin de trouver ses coordonnées. Si vous n’arrivez pas à les repérer, communiquez avec nous à PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca.

Questions? Contact the NRC Publications Archive team at

PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca. If you wish to email the authors directly, please see the first page of the publication for their contact information.

https://publications-cnrc.canada.ca/fra/droits

L’accès à ce site Web et l’utilisation de son contenu sont assujettis aux conditions présentées dans le site

LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D’UTILISER CE SITE WEB.

READ THESE TERMS AND CONDITIONS CAREFULLY BEFORE USING THIS WEBSITE.

https://nrc-publications.canada.ca/eng/copyright

NRC Publications Archive Record / Notice des Archives des publications du CNRC :

https://nrc-publications.canada.ca/eng/view/object/?id=2ab0b251-ff54-4ed1-be99-ae881cf4dc1b https://publications-cnrc.canada.ca/fra/voir/objet/?id=2ab0b251-ff54-4ed1-be99-ae881cf4dc1b

NRC Publications Archive

Archives des publications du CNRC

Access and use of this website and the material on it are subject to the Terms and Conditions set forth at Impact of air leakage on hygrothermal and energy performance of buildings in North America. Part III: energy rating of insulated wall assemblies

Maref, W.; Saber, H. H.; Elmahdy, A. H.; Swinton, M. C.; Glazer, R.; Nicholls, M.

(2)

PART III: Energy

Rating of

Insulated Wall Assemblies

NRC - Institute for Research in Construction

Dr. Wahid Maref

Team Work: H.H. Saber, H. Elmahdy, M.C. Swinton, R. Glazer & M. Nicholls

(3)

NRC-IRC Building Envelope & Structure Program

Outline

• Background

• Project objectives

• Scope

• Proposed energy rating procedure

for insulated wall assemblies

• Results of recent research project

• Closing remarks

(4)

Background

• Canadian Building Code Requirements:

o

Control of air, water, sound, etc.

• Canadian Construction Materials Center (CCMC) Air

Barrier Guide 1996

• Move towards Energy Code

• Energy rating of building envelope components

• Focus on insulated wall assemblies

(5)

NRC-IRC Building Envelope & Structure Program

Functions and Regulations

• Some of the these functions are regulated by

National or Provincial/Territorial Building Codes

(e.g., structural, fire,… etc.)

• Currently, energy codes and some provincial

building codes have requirements related to

the thermal performance as related to conduction

heat loss (e.g., U-factor or R-value) and air leakage

performance of the envelope

(6)

Codes and Standards Dilemma

It is difficult to incorporate the effect of

air leakage through the envelope on

the overall thermal performance of the

wall system

(7)

NRC-IRC Building Envelope & Structure Program

Project Objective:

• To determine Wall Energy Rating (WER) of

walls constructed according to field practices

with spray polyurethane foam insulation, by

combining measured heat losses due to

conduction and air leakage.

• The work was extended to cover walls with

(8)

Overview of the WER Project

• Wall samples built to common construction

practices

• Testing for thermal resistance

and air leakage

• Material characterization

• Computer simulation

(9)

NRC-IRC Building Envelope & Structure Program

This Talk

• Presents the results of six wall samples: two glass

fiber walls (reference walls), and four SPF insulated

walls with light density (open cell foam).

• Other walls were reported in a series of published

papers

• A total of 16 walls were tested, modeled and

documented so far.

• More publications:

English:

http://www.nrc-cnrc.gc.ca/eng/ibp/irc/publications/index.html

(10)

WER 1 and WER 5

• These 2 walls are intentionally

built not to the

requirements of

Part 9 of the Canadian National Building Code (NBC)

to

introduce a wide range of air leakage rates.

• Part 9 NBC gives 2 options for air barrier continuity:

o

Sealing the joint, or

o

Lapping the joint by not less than 100 mm and clamping between framing

members and rigid panel

• NBC also requires sealing of windows, piping, ducting and

electrical boxes to maintain the integrity of the air barrier (

All

penetration were not all sealed to meet the NBC

(11)

NRC-IRC Building Envelope & Structure Program

Wall Samples:

Six 2” x 6” spruce stud walls, 16” spacing (nominal)

• one sample without penetration, with poly-lapped air barrier

(fibrous insulation wall sample WER-1)

• one sample similar to the one

above but with penetration (WER-5)

• The spray foam is light density (open cell),

four samples, different foams, w/out penetration (WER-AA to

DD)

(12)

Wall samples:

Wall #

Insulation type

Description

WER-1

Fibrous insulation

(poly-lapped air barrier)

Reference wall, without

penetrations

WER-5

Same as above

Same as above, but with

penetrations

WER-AA

Open cell foam

Blank wall, without

penetrations

WER-BB

Open cell foam, same as

above

With penetrations

WER-CC

Different brand of open

cell foam

Without penetrations

(13)

NRC-IRC Building Envelope & Structure Program

96.00

96.00

2X6 in Economy Grade SPF Studs, 16 in on Center

Hexagonal and rectangular external junction boxes installed in accordance with construction practice

0.50 in gap (12.5 mm) Typical gap 1/4 - 1/2 in (6.35 - 12.5 mm) Double Top Header Stud Fastening: 3 1/2 in Spiral Nails, 2 minimum per stud-plate interface

Top Header Fastening; 3 in spiral nails on 16 in centers, 2 minimum per spacing

49.75

3/4 in hole bored 2 1/2 in from weatherside surface for 14-2 electrical wire

22.00 1.5 in PVC (38 mm) Galvanized duct 3.94 in (100 mm) window 47.2 x 23.6 in (600 x 1200 mm) 5.91 19.51

Penetrations Layout

(14)

Cross-section of typical wall samples

Weather resistive

barrier membrane

OSB Sheathing

11 mm

Spruce bottom plate

and studs

Spruce

top plate

Gypsum, 12 mm

Insulation, glass

fiber, stud thickness

140 mm

Polyethylene sheet, 6-mil

Air/vapor barrier

2400 x 2400 mm

wall sample

Fibrous

insulation

SPF (open cell)

insulation

Insulation,

polyurethane

spray foam,

stud thickness

140 mm

(15)

NRC-IRC Building Envelope & Structure Program

Thermocouples location:

B201 B203 B207 B209 B313 B317 B319 B211 B213 B217 B219 B301 B303 B307 B309 C201 C203 C207 C209

Thermocouple

grid

Interstitial

thermocouples

Heat flux

transducer

(16)
(17)

NRC-IRC Building Envelope & Structure Program

Blank wall with fibrous insulation

and poly-lapped air barrier

(18)

Wall Energy Rating (WER)

Project overview

Experimental Part Numerical Part Model development and implementation Computer Simulation Results Development of Test protocol Instrumentation

Test and Boundary Conditions Material Characterization

Performing Experiments

Comparison & Analysis Input

Results

(19)

NRC-IRC Building Envelope & Structure Program

Test Sequence

R-value in GHB

Sample Conditioning

Air leakage test

Air leakage test

R-value in GHB

GHB

Guarded Hot Box

Air Leakage & Conditioning Test Apparatus

ASTM E283

ASTM C1199 and

ASTM E1423

CCMC Air Barrier

(20)

Pressure and gust wind cycles

Sample conditioning

Pressure cycle for sample conditioning

-1600 -800 0 800 1600 Time, s Pressure di fference , Pa P2 P'2 P3 P'3 Repeated positive pressure n times. Repeated negative pressure n times.

Cyclic loads Gust loads

3s 1s 1s

Conditioning (Weathering), +800 Pa, 1000 cycles

100 200 300 400 500 600 700 800 900 D iff er en tial P re ss ur e, P a

(21)

NRC-IRC Building Envelope & Structure Program

Air Leakage and Conditioning Test

Apparatus

Data acquisition

and control PC

Air leakage and

conditioning unit

New aluminum

frame holder

WER wall specimen

(22)
(23)

NRC-IRC Building Envelope & Structure Program

Test Procedures

• Air leakage (ASTM E283)

• Wall thermal resistance (ASTM C1199 and

ASTM E1423)

• Material characterization (ASTM C518-98)

using heat flow meter

• Sample conditioning according to CCMC

Technical Guide (Masterformat Section 07272,

section 6.62, page 14 )

(24)

Results

• Test results

o

Air leakage

o

Thermal resistance, R-value

o

Material characterization of foam(s)

• Simulation results

• Comparison of testing and simulation

• Development of WER

(25)

NRC-IRC Building Envelope & Structure Program

Foam characterization:

Wall Parameter

Symbol

WER-AA &

BB

WER-CC &

DD

Test Mean

temperature

T

m

(°C)

0.2

0.3

Material density

ρ (Kg/m

3

)

12.0

7.8

Thermal

conductivity, SI

units

λ (W/(m.K))

0.0352

0.0388

(26)

Air leakage test results (WER-1)

0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 25 50 75 100 125 150 175 Flo w Ra te, L/(s *m ^ 2 ) Differential Pressure, Pa CCMC Limit Wall unconditioned Wall conditioned (final)

WER-1, Air Leakage, Glass Fiber (Reference Wall) Net Infiltration, No penetration

Electric outlet is NOT sealed

(27)

NRC-IRC Building Envelope & Structure Program

Air leakage test results: WER-AA

and WER-BB

WER-AA

WER-BB

0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0 25 50 75 100 125 150 175 Flo w Ra te, L/(s *m^ 2) Differential Pressure, Pa CCMC Limit Wall unconditioned Wall conditioned

WER-AA, Air Leakage, Demilec - OCF, Net Infiltration, No penetration

0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0 25 50 75 100 125 150 175 Flow Rate, L/(s*m^ 2) Differential Pressure, Pa CCMC Limit Wall unconditioned Wall conditioned

(28)

Air leakage test results: WER-CC

and WER-DD

WER-CC

WER-DD

0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0 25 50 75 100 125 150 175 Flow Rate, L/(s*m^ 2) Differential Pressure, Pa CCMC Limit Wall unconditioned Wall conditioned

WER-CC, Air Leakage, BASF - OCF, Net Infiltration, No penetration

0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10 0 25 50 75 100 125 150 175 Flo w Ra te, L/(s *m^ 2) Differential Pressure, Pa CCMC Limit Wall unconditioned Wall conditioned

(29)

NRC-IRC Building Envelope & Structure Program

R-value test results

Cold

temperature -20 C -35 C

R-value of conditioned walls, m2.K/W

Wall # m2.K/W F.ft2.hr/BTU m2.K/W F.ft2.hr/BTU

WER-1 3.25 18.45 3.44 19.53 WER-5 2.78 15.79 2.84 16.13 WER-AA 3.59 20.38 3.60 20.44 WER-BB 3.30 18.74 3.24 18.39 WER-CC 3.36 19.07 3.26 18.51 WER-DD 3.00 17.03 3.02 17.14

(30)

Computer Modelling

• Use hygIRC-C to predict the R-values for the

all walls with no air leakage and compare its

prediction with measured results

• Use hygIRC-C to predict the R-values at

different leakage rates for all walls

• Provide a simple correlation to be used for

determining the R-values at different

leakage rates

(31)

NRC-IRC Building Envelope & Structure Program

Benchmarking of the Two Models

Drywall

Foam Air Stud Foam Air

OSB

hygIRC 2-D model

hygIRC-C 3-D model

hygIRC-C

Temperature Profiles

hygIRC

(32)

Air Velocity Field

Airflow

Sample of 3D Results (cont’d)

WER-1,

DP = 75 Pa

(33)

NRC-IRC Building Envelope & Structure Program

Comparison between lab test and

simulation results (R-value)

(34)

Introduction of R-value Ration

β

This factor shows the impact of

air leakage on the wall R-value

(R-value with air leakage)

value without air leakage)

L

o

R

R

(35)

NRC-IRC Building Envelope & Structure Program

What is Wall Energy Rating (WER)?

• A tool for energy rating of wall assemblies

that addresses the building physics and

accounts for:

o

Heat loss due to thermal conduction through

the system

o

Heat loss due to air leakage through the system

o

Interaction between the two modes of heat loss.

Provides a means to assess the overall performance of

the system

(36)

Determination of WER

• Need

o

R-value WITHOUT air leakage (GHB), m

2

.K/W

o

Air leakage rate,

ξ, at ΔP = 75 Pa, l/(s.m

2

)

Determine wall “apparent” R-value with

air leakage at different

ΔP values

• Determine the apparent R-value ratio,

β

(37)

NRC-IRC Building Envelope & Structure Program

Correlation of

β with air leakage rate

(6 walls):

0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 WER-1 WER-5 WER-AA WER-BB WER-CC WER-DD -3% +3% 6 Walls at 75 Pa CCMC Criterion ( = 0.05 L/(s.m2)  = exp(a*b) a = -1.53, b = 0.89

Leakage Rate,

(L/(s.m

2

))

-V

a

lu

e

(38)

LR @ 75 Pa,

(

L/(s.m

2

))

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.4 0.6  = exp(a*b) a = -1.54, b = 0.89  -V a lu e

exp(

a

b

)

T

D

RSI

0 0

RSI

RSI

L

(39)

NRC-IRC Building Envelope & Structure Program

CSA A-440.2 Standard Approach

ER

cal

Window Energy Rating

Solar heat gain

Conduction heat loss

Air leakage heat loss

ER

cal

(40)

WER: A tool for wall energy rating

WER Wall Energy Rating

Conduction heat loss

Air leakage heat loss

(41)

NRC-IRC Building Envelope & Structure Program

Effect of Air Leakage on WER

(42)

Effect of Air Leakage on WER

Case II

(43)

NRC-IRC Building Envelope & Structure Program

What is next?

• Develop energy rating tools for other building

components

• Combine all the tools in a master protocol to

determine the energy rating of the whole building

envelope

• This will be a step towards energy labeling of

buildings

• A new consortium will be meeting soon to discuss

(44)
(45)

NRC-IRC Building Envelope & Structure Program

Insulated Concrete Forms (

ICF’s) and

Structural Insulated Panels (

SIP’s):

ICF

(46)

Closing Remarks

• A new procedure is now available to determine the

energy performance of insulated wall assembly,

with and without penetration

• The procedure requires a minimum laboratory

testing

• Computer simulation proven to be very useful and

accurate in predicting the R-value of the wall, with

and without air leakage

(47)

NRC-IRC Building Envelope & Structure Program

Closing Remarks

(cont’d)

• It is necessary to include additional materials

and construction practices to generate

comprehensive correlation

• Efforts are underway to invite others to join

this project

• Next step is to develop national (and

(48)

Acknowledgement

• We would like to acknowledge the

contribution of the project team and the

partners in this project:

o

BASF

o

CUFCA

o

Demilec

o

Honeywell

(49)

NRC-IRC Building Envelope & Structure Program

Discussion

Thank you

Contact information:

Références

Documents relatifs

Ignition of the tH3 alone was not achieved; when the gasoline-air ratio was made too lean, the engine would stall even though the correct amount of iH3

Identification tools used to reach this goal are not equivalent and may depend on several objectives and constraints, including sampling conservation difficulties, the invasiveness

This significant difference in rheological behavior was attributed to the higher specific surface area (and chemical reactivity) of the rice husk particles and the presence of silica

To determine whether the chemical structure of oxidation products plays a role in the alteration of the PV properties of the devices, we have reported below the evolution of

‐  Another  system  impacting  wine  inventory  management  exists  and  regards  wine  under  geographical  indications  of  origins.  Wine  companies  can 

Here, we use momentum-resolved electron energy loss spectroscopy (k-EELS) to perform the first experimental demonstration of high-k modes and hyperbolic Cherenkov radiation in