• Aucun résultat trouvé

Construction de 5 ombrières photovoltaïquessur un parking et boulodrome

N/A
N/A
Protected

Academic year: 2022

Partager "Construction de 5 ombrières photovoltaïquessur un parking et boulodrome"

Copied!
12
0
0

Texte intégral

(1)

31 rue de la Frébardière 35135 CHANTEPIE Tél: 07 86 95 34 33

Maitrise d'ouvrage

Construction de 5 ombrières photovoltaïques sur un parking et boulodrome

Edition : 21/05/2021

DEMANDE D'EXAMEN AU CAS PAR CAS

DEMANDE D'EXAMEN AU CAS PAR CAS

PREALABLE A LA REALISATION D'UNE ETUDE D'IMPACT

Contact

Alexandre GUERIN pc@seeyousun.fr

07 86 95 34 33

La Pacauderie,

44680 Chaumes-en-Retz

(2)

Date

ANNEXE 2

PLAN DE SITUATION

Echelle :

1/25000

N

A-02

EXTRAIT CADASTRAL

REFERENCE CADASTRALE DU PROJET :

VUE AERIENNE PLAN DE SITUATION

040 G 3405 / 4 682 m

2

040 G 1836 / 11 603 m

2

Ombrières en panneaux photovoltaïques

La Pacauderie,

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

(3)

Date

ANNEXE 3

ENVIRONNEMENT PROCHE

Echelle :

A-03a -

ENVIRONNEMENT PROCHE N

21/05/2021

Ombrières en panneaux photovoltaïques

La Pacauderie,

44680 Chaumes-en-Retz 31 rue de la Frébardière, 35135 CHANTEPIE

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

mars 2021 mars 2021

(4)

ANNEXE 3 Echelle :

- ENVIRONNEMENT LOINTAIN

ENVIRONNEMENT LOINTAIN N

Ombrières en panneaux photovoltaïques

La Pacauderie,

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

mars 2021 mars 2021

(5)

Date

ANNEXE 3

INSERTION DANS LE SITE

Echelle :

A-03c 21/05/2021 -

Boulodrome VUE SUD

Parking

VUE OUEST

Ombrières en panneaux photovoltaïques

La Pacauderie,

44680 Chaumes-en-Retz 31 rue de la Frébardière, 35135 CHANTEPIE

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

(6)

ANNEXE 4 Echelle :

1/500 PLAN DE MASSE - ETAT EXISTANT

PLAN DE MASSE ETAT EXISTANT

Ombrières en panneaux photovoltaïques

La Pacauderie,

N

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

+0.3 = +13.80 Ngf

1

+0.00 = +13.50 Ngf

Limite Séparative Limite Séparative

Limite Séparative

Limite Séparative Limite Séparative

Limite Séparative +0.50 = +14.00 Ngf

+0.30 = +13.80 Ngf

37

1

13.1 16

16

125.2 8.5

22 27

+0.3 = +13.80 Ngf

11.1

10 6

5 5

2.5

5 5.2 5

2.5

5.1 Espace de jeu - Boulodrome

30.9

Accès Accès

(7)

Date

ANNEXE 4 Echelle :

1/500

A-04b

N

PLAN DE MASSE - ETAT PROJET

PLAN DE MASSE - ETAT PROJET

21/05/2021

Ombrières en panneaux photovoltaïques

La Pacauderie,

44680 Chaumes-en-Retz 31 rue de la Frébardière, 35135 CHANTEPIE

Emplacement compteur Enedis Liaison DC

Liaison AC

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

+0.3 = +13.80 Ngf

21.1 1.1

5.1

5.2

1010

1

Point haut : +4.10 =+17.60 Ngf Surface Ombrière 3 : 131 m2

pente: 8°

Point bas : +3.20 =+16.70 Ngf

6.2

1

30 10

5.1

5.2

1010

1

Point haut : +4.60 =+18.10 Ngf Surface Ombrière 4: 186 m2

pente: 8°

Point bas : +3.70 =+17.20 Ngf

6.2

+0.00 = +13.50 Ngf

Surface totale : 16 285 m² Surface Ombriéres : 1 452 m²

Limite Séparative Limite Séparative

Limite Séparative

Limite Séparative Limite Séparative

Limite Séparative +0.50 = +14.00 Ngf

+0.30 = +13.80 Ngf

10

5.1

6.2

1010

6.2

Point haut : +6.05 =+19.55 Ngf Surface Ombrière 2 : 460 m2

pente: 8°

Point bas : +4.30 =+17.80 Ngf

12.4

7

37

5.1

6.7 6.7

Point haut : +6.19 =+19.69 Ngf Surface Ombrière 1 : 500 m2

pente: 8°

Point bas : +4.30 =+17.80 Ngf

13.5

17.2

19.7 9.7

1

37.7

15.4

3

28.2

7.5

5.1

5.2

1010

1

Point haut : +4.40 = +17.90 Ngf Surface Ombrière 5 : 175 m2

pente: 8°

Point bas : +3.50 =+17.00 Ngf

6.2

0.7

6.4

8.8

4.8 6.3

3.5 13.1

9.5 4.1

32.5 32

16

16

156.1 8.5

22 27

5

+0.3 = +13.80 Ngf

5

Liaison en plexiglass

11.1

5

11.1

Accès Accès

(8)

+0.3 = +13.80 Ngf

21.1

5.1 Point haut : +4.10 =+17.60 Ngf

Surface Ombrière 3 : 131 m2 pente: 8°

Point bas : +3.20 =+16.70 Ngf 6.2

1

30

5.1 Point haut : +4.60 =+18.10 Ngf

Surface Ombrière 4: 186 m2 pente: 8°

Point bas : +3.70 =+17.20 Ngf 6.2 +0.00 = +13.50 Ngf

Surface totale : 16 285 m² Surface Ombriéres : 1 452 m²

Limite Séparative Limite Séparative Limite Séparative

Limite Séparative Limite Séparative

Limite Séparative

+0.50 = +14.00 Ngf

+0.30 = +13.80 Ngf 5.1

Point haut : +6.05 =+19.55 Ngf

Surface Ombrière 2 : 460 m2 pente: 8°

Point bas : +4.30 =+17.80 Ngf 12.4 37

5.1 Point haut : +6.19 =+19.69 Ngf

Surface Ombrière 1 : 500 m2 pente: 8°

Point bas : +4.30 =+17.80 Ngf 13.5

17.2 19.7

9.7 1

37.7

15.4 3

28.2 Point haut : +4.40 = +17.90 Ngf

Surface Ombrière 5 : 175 m2 pente: 8°

Point bas : +3.50 =+17.00 Ngf 6.2 6.4 8.8

4.8 6.3

3.5

13.1 4.1 9.5

32.5

32 16

16

125.2 8.5

22

27 5

+0.3 = +13.80 Ngf Liaison en plexiglass 11.1

5

11.1

Accès

Accès

Echelle :

-

Ombrières en panneaux photovoltaïques

La Pacauderie,

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

N

ANNEXE 5 PLAN DES ABORDS Bande de 100m

Réservoir d'eau

Bâtiment à caractère industriel, commercial ou agricole

Sylviculture

Réservoir d'eau Sylviculture

Zone à usage résidentiel

Zone à usage résidentiel

Pratique sportive

Zone agricole Zone agricole

Zone agricole

Zone agricole

Zone agricole

Zone agricole

Pratique sportive

Pratique sportive

Zone à usage résidentiel

(9)

7.2Km

Date

Echelle :

21/05/2021 -

A-06a

Ombrières en panneaux photovoltaïques

La Pacauderie,

44680 Chaumes-en-Retz 31 rue de la Frébardière, 35135 CHANTEPIE

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

SITE NATURA 2000 DIRECTIVE HABITATS Identifiant : FR5200621 Estuaire de la Loire

N

ANNEXE 6

SITUATION DU PROJET PAR RAPPORT AUX SITES NATURA 2000

SITE NATURA 2000

DIRECTIVE OISEAUX

Identifiant : FR5210103

Estuaire de la Loire

(10)

+0.3 = +13.80 Ngf

21.1

5.1 Point haut : +4.10 =+17.60 Ngf

Surface Ombrière 3 : 131 m2 pente: 8°

Point bas : +3.20 =+16.70 Ngf 6.2

1

30

5.1 Point haut : +4.60 =+18.10 Ngf

Surface Ombrière 4: 186 m2 pente: 8°

Point bas : +3.70 =+17.20 Ngf 6.2 +0.00 = +13.50 Ngf

Surface totale : 16 285 m² Surface Ombriéres : 1 452 m²

Limite Séparative Limite Séparative Limite Séparative

Limite Séparative Limite Séparative

Limite Séparative

+0.50 = +14.00 Ngf

+0.30 = +13.80 Ngf 5.1

Point haut : +6.05 =+19.55 Ngf

Surface Ombrière 2 : 460 m2 pente: 8°

Point bas : +4.30 =+17.80 Ngf 12.4 37

5.1 Point haut : +6.19 =+19.69 Ngf

Surface Ombrière 1 : 500 m2 pente: 8°

Point bas : +4.30 =+17.80 Ngf 13.5

17.2 19.7

9.7 1

37.7

15.4 3

28.2 Point haut : +4.40 = +17.90 Ngf

Surface Ombrière 5 : 175 m2 pente: 8°

Point bas : +3.50 =+17.00 Ngf 6.2 6.4 8.8

4.8 6.3

3.5

13.1 4.1

9.5

32.5

32 16

16

125.2 8.5

22

27

5

+0.3 = +13.80 Ngf Liaison en plexiglass 11.1

5

11.1

Accès

Accès

13m

Echelle :

-

Ombrières en panneaux photovoltaïques

La Pacauderie,

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

N

ANNEXE 6

SITUATION DU PROJET PAR RAPPORT AUX ZNIEFF ZNIEFF DE TYPE 1

Identifiant : 520006635

BOIS DES ILES ENCHANTEES ET PELOUSES CALCAIRES RESIDUELLES

D'ARTHON-CHEMERE

ZNIEFF DE TYPE 1 Identifiant : 520006635

BOIS DES ILES ENCHANTEES ET PELOUSES CALCAIRES RESIDUELLES

D'ARTHON-CHEMERE

(11)

2.1 6.2

+3.20

+0.00 m = +13.50Ngf +4.10

8.0° 2.1

6.2 +3.70

+0.50 m = +14.00Ngf +4.60

8.0° 2.1

6.2 +3.50

+0.30 m = +13.80Ngf +4.40

8.0°

2.8 (min)

13.6

6.7

2.2

6.7 +0.00 m = +245.10Ngf

+6.19 m

+4.30 m

12.5

6.2

2.2

6.2

+0.30 m = +13.80Ngf +6.05 m

+4.30 m

8.0° 8.0°

Ombrière 1 Ombrière 2

Ombrière 3 Ombrière 4 Ombrière 5

Liaison en plexiglass

10 10 10

37

+4.30 = +17.80 Ngf

+6.05 = +19.55 Ngf 7

+0.00 m = +13.80Ngf

7.5 10

10

28.2

+3.50 = +17.00 Ngf +4.40 = +17.90 Ngf 0.7

+0.30 m = +13.80Ngf

Ombrière 2

Ombrière 5

10 10

10

37

+4.30 = +17.80 Ngf +6.19 = +19.55 Ngf 7

+0.00 m = +13.80Ngf

1.1 10 10

21.1

+0.00 m = +13.50Ngf +3.20 = +16.70 Ngf

+4.10 = +17.60 Ngf

Ombrière 1

Ombrière 3

2.1

6.2 +3.20

+0.00 m = +13.50Ngf

+4.10

8.0°

2.1

6.2 +3.70

+0.50 m = +14.00Ngf

+4.60

8.0°

2.1

6.2 +3.50

+0.30 m = +13.80Ngf

+4.40

8.0° 2.8 (min)

13.6

6.7

2.2

6.7

+0.00 m = +245.10Ngf +6.19 m

+4.30 m 12.5

6.2

2.2

6.2 +0.30 m = +13.80Ngf

+6.05 m

+4.30 m

8.0°8.0°

Ombrière 5 Ombrière 4 Ombrière 3

Ombrière 2 Ombrière 1

Liaison en plexiglass

Date

ANNEXE 7

FAÇADES PROJET

Echelle :

1/400

A-07

FACADE SUD-OUEST PROJET

FACADE NORD-EST PROJET

FACADE NORD-OUEST PROJET FACADE SUD-EST PROJET

21/05/2021

Ombrières en panneaux photovoltaïques

La Pacauderie,

44680 Chaumes-en-Retz 31 rue de la Frébardière, 35135 CHANTEPIE

DEMANDE D'EXAMEN AU CAS PAR CAS PRÉALABLE A LA RÉALISATION D'UNE

ÉTUDE D'IMPACT

(12)

Annexe 8 : NOTICE DESCRIPTIVE 1-PRESENTATION DU PROJET

Le projet concernant cette demande d’étude au cas par cas, consiste à construire 5 ombrières photovoltaïques sur un boulodrome et sur un parking situé à La Pacauderie, 44680 Chaumes-en-Retz. La puissance totale à installer est de 300kWc. L’énergie électrique produite sera réinjectée sur le réseau public et revendue à EDF.

Le site d’étude des futures installations est situé dans la commune Chaumes-en-Retz, département de la Loire Atlantique, le projet en question occupera les parcelles du parking existant, dont la superficie totale est de 16 285 m², sous les références cadastrales suivantes : 040 G 3405 / 4 682 m2 ; 040 G 1836 / 11 603 m2

Le site dans lequel sera aménagé les futures installations, se situe au niveau du parking et du boulodrome, le terrain est légèrement plat, il est délimité ainsi : A l’Est : par des terrains de foot. Au Nord : par un terrain agricole

A l’Ouest : par des maisons individuelles Au sud : par des maisons individuelles 2- CARACTERISTIQUES DU PROJET

Le principe d’aménagement :

Le projet de notre demande du permis de construire, consiste à la réalisation de 5 ombrières en panneaux photovoltaïques. Au regard du terrain, l’emprise au sol des installations sera partielle, dans la mesure où ces dernières couvriront 1452 m2, sans modification des tracées et la topographie des parkings. Les ombrières se déploieront suivant l’axe nord-est du terrain.

Configuration :

Ombrière 01 (Boulodrome) :

- Largeur : 12.4 m. Longueur : 37 m.

- Hauteurs : Point bas +4.30 m. Point haut +6.05 m.

- Structure : 5 massifs.

Ombrière 02 (Boulodrome) :

- Largeur : 13.5 m. Longueur : 37 m.

- Hauteurs : Point bas +4.30 m. Point haut +6.19 m.

- Structure : 5 massifs.

Ombrière 03 :

- Largeur : 6.2 m. Longueur : 21.1 m.

- Hauteurs : Point bas +3.20 m. Point haut +4.1 m.

- Structure : 3 massifs.

Ombrière 05 :

- Largeur : 6.2 m. Longueur : 28.2 m.

- Hauteurs : Point bas +3.50 m. Point haut +4.4 m.

- Structure : 4 massifs.

Ombrière 04 :

- Largeur : 6.2 m. Longueur : 30 m.

- Hauteurs : Point bas +3.70 m. Point haut +4.6 m.

- Structure : 4 massifs.

Les futures installations auront très peu d’impact sur la surface foncière du site, les espaces verts ne seront pas impactés par l’aménagement et l’installation des futures ombrières. Les eaux pluviales des ombrières seront collectées et évacuées via le réseau des eaux pluviales du parking existant, le projet ne créera pas des surfaces imperméabilisées. La liaison AC sera enterrée.

La composition Architecturale :

Notre parti-pris architectural vise à assurer la parfaite intégration des ombrières, dans leur environnement proche et lointain. Les ombrières des parkings offriront au site un confort aux usagers, au-delà des bénéfices dû à la génération de l’énergie électrique, l’installation servira également comme élément de protection double en cas d’ensoleillement ou par un temps de pluie.

Notre problématique, concernant le projet consistera à proposer une architecture à l’échelle humaine par : - Le type de structure adopté : structure métallique légère avec très peu d’impact au sol,

- La couverture sera formée par des capteurs solaires photovoltaïques, les ombrières auront une pente de 8°

- La puissance totale des panneaux photovoltaïques : 300 kWc, 100% de l’énergie produite est destiné à la revente en injection réseau.

Les matériaux proposés :

- Structure primaire et secondaire : métal acier galvanisé.

- Capteurs solaires : panneaux photovoltaïques.

- Éclairage intégré sous les ombrières.

Fondations :

Chaque pieu est solidement scellé dans le sol. Pour se faire, le goudron sera retiré au pied des pieux sur 30 à 50 cm de profondeur afin de couler une dalle de béton armé, dimensionnée selon les normes Eurocodes, pour résister aux pires conditions climatiques de la zone d’installation. Les dalles de béton seront prises dans des tiges en acier spécifiques pour maintenir la structure métallique. En moyenne, un pieu sera installé tous les 10 mètres.

Références

Documents relatifs

[r]

Le projet à pour objectif la construction et l'exploitation d'une centrale photovoltaïque en ombrières de parking d'une puissance de 2.15 MWc, implantée sur le parking de la

Figure 1 : Carte IGN au 1/25 000 de la localisation du projet (les parkings du Safari Parc de Peaugres) Localisation du projet... La communication entre les 2 parkings se fait par

Le projet à pour objectif la construction et l'exploitation d'une centrale photovoltaïque en ombrières de parking pour poids lourds d'une puissance de 494 kWc, implantée sur le

Considérant que le projet consiste en l’installation de trois ombrières photovoltaïques sur le parking de la piscine et sur le boulodrome, rue de

Le site dans lequel sera aménagées les futures ombrières, se situe au niveau du parking de la piscine et le boulodrome, le terrain est plat, il est délimité ainsi :. Au Nord : par

Si le projet est situé dans ou à proximité d’un site Natura 2000, est-il. susceptible d’avoir un impact sur un habitat / une espèce inscrit(e) au Formulaire Standard

Vu la demande d’examen au cas par cas n°2020-4634 relative au projet de construction d’ombrières photovoltaïques de parking sur la