• Aucun résultat trouvé

CZC-GC miniaturized analysis of POPs in 20 µL blood

N/A
N/A
Protected

Academic year: 2021

Partager "CZC-GC miniaturized analysis of POPs in 20 µL blood"

Copied!
1
0
0

Texte intégral

(1)

CZC-GC miniaturized analysis of POPs in 20 µL blood

L’Homme B., Focant JF.

Organic and Biological Analytical Chemistry, Chemistry Department, University of Liège, Allée de la Chimie 3, B-6c Sart-Tilman, B-4000 Liège, Belgium.

Please circle below the appropriate answer:

Author 1 accepts, if selected, to give an oral presentation: YES – NO

Author 1 accepts, if assigned a poster, to give a 5 min flash presentation: YES - NO

Humans all over the world are exposed to chemicals during their life time. Among the thousands of existing anthropogenic compounds are the persistent organic pollutants (POPs), including compounds like polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), but also a large number of new molecules like halogenated flame retardants (HFRs). Nowadays, POP (temporal) human biomonitoring is classically performed on serum specimen. Typically, 5-75 mL of whole blood are sampled from patients and analyzed by state-of-the-art GC isotope dilution (ID) sector HRMS. Even if much less invasive than the classical surgical abdominal fat removals that were performed in the 1980’s, the venipunction of several milliliters of whole blood for analytical purpose is still badly perceived by patients.

The aim of the work is to develop and miniaturize an analytical strategy based on cryogenic zone compression (CZC) of chromatographic signals for the analysis of selected POPs in 20µL whole blood. The method can be considered as (almost) non-invasive since samples are simply prepared by pricking the heel or the finger to collect a few drops of blood.

The procedure was partially automatized using micro-extraction by packed sorbent (MEPS) for sample preparation and a GC×GC high-resolution (HR) time-of-flight (TOF) mass spectrometer (MS) for fast analysis. MEPS extraction, which was the key part of the development, led to clean spectrum without further clean up. The miniaturization was pushed to its limits since the total amount of solvent used was as low as 500µL.

The GC×GC instrumentation is used in the cryogenic zone compression (CZC) mode, particularly suitable for low level target analysis with extreme enhancement of signals. Search for unknown and/or emergent compounds is also investigated, thanks to both the large chromatographic separation space available and the analytical power of the TOFMS instrument.

Références

Documents relatifs

Le développement continu des codes de convection mantellique dans la modélisation de la dynamique interne de la Terre et de la tectonique de surface suggère un objectif à long

The purpose of this paper is to quantify the contribution of each component of population change (in- and out-migration, HIV seroconversion, ageing into the cohort and definitive

1) L'avertissement, loin d'être symbolique, constitue une sanction. Premier grade dans l'échelle des sanctions, l'avertissement peut contribuer à prévenir une dégradation

(i) the TEPI (Trace Element Pollution Index) allowing the reliable comparison of global pollution levels in TEs between several monitored sites.. How to compare global pollution

Polyvinyl chloride (PVC) is the plastics niatcrial that has probably rcccived the most attention froni firc authorities because of its relatively wide use and

y = Xb + qs + hd+ QWt+Za+Zp+e where y is a vector of milk, fat or protein TD records, b is a vector of the usual fixed effects, q is a vector of known or estimated numbers of

Composition and length of the PEOMA branches have been changed, and the aggregates formed in water have been analyzed by dynamic light scattering (DLS) and observed by