• Aucun résultat trouvé

Analysis of POPs in 20μL blood by MEPS-GC-MS/MS

N/A
N/A
Protected

Academic year: 2021

Partager "Analysis of POPs in 20μL blood by MEPS-GC-MS/MS"

Copied!
1
0
0

Texte intégral

(1)

Analysis of POPs in 20µL blood by MEPS-GC-MS/MS

L’homme B, Focant JF

Organic and Biological Analytical Chemistry, Chemistry Department, University of Liège, Allée de la Chimie 3, B-6c Sart-Tilman, B-4000 Liège, Belgium.

Humans all over the world are exposed to chemicals during their life time. Among the thousands of existing anthropogenic compounds are the persistent organic pollutants (POPs), including compounds like polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), but also a large number of new molecules like halogenated flame retardants (HFRs). Nowadays, POP (temporal) human biomonitoring is classically performed on serum specimen. Typically, 5-75 mL of whole blood are sampled from patients and analyzed by state-of-the-art GC isotope dilution (ID) sector HRMS. Even if much less invasive than the classical surgical abdominal fat removals that were performed in the 1980’s, the venipunction of several milliliters of whole blood for analytical purpose is still badly perceived by patients.

The aim of the work is to develop and miniaturize an analytical strategy for the analysis of representative POPs in small sample volumes. Samples consist in 20µL liquid whole blood and ultimately dried-blood spots. This sample method can be considered as non-invasive since a few drops of blood are collected on a filter paper. The strategy is based on a micro-scale sample preparation: micro-extraction by packed sorbent (MEPS). The instrumental analysis is performed on an Agilent 7000 GC-QQQ.

The extraction procedure was partially automated using MEPS syringes and provided clean extracts that didn’t require further clean up. The miniaturization was pushed to its limits since the total amount of solvent used was as low as 500µL. The GC triple quadrupole analyzer has shown limits of detection for targets in the same order than the very sensitive GC-HRMS instrumentation making possible analyzes of trace level compounds in small samples.

Références

Documents relatifs

J’ai pu grâce à lui passer d’un sujet vaste, le « neuromarketing », à l’étude plus spécifique des données émotionnelles de la start-up Datakalab et à la manière dont

(i) the TEPI (Trace Element Pollution Index) allowing the reliable comparison of global pollution levels in TEs between several monitored sites.. How to compare global pollution

The purpose of this paper is to quantify the contribution of each component of population change (in- and out-migration, HIV seroconversion, ageing into the cohort and definitive

In Sec. III A a mathematical approach is presented con- sidering that the total number of particles in the system is conserved, which is used in following sections. III B the

Composition and length of the PEOMA branches have been changed, and the aggregates formed in water have been analyzed by dynamic light scattering (DLS) and observed by

D’un point de vue strictement méthodologique, l’auteure affirme que si l’œuvre d’art peut être analysée comme texte (énoncé) et comme objet (au sens entendu

Polyvinyl chloride (PVC) is the plastics niatcrial that has probably rcccived the most attention froni firc authorities because of its relatively wide use and

One radical example is that recently, the United Nations Sub-Commission for the Promotion and Protection of Human Rights approved ‘Norms on the Responsibility of