• Aucun résultat trouvé

Enantiomeric purity testing of S-timolol by non-aqueous CE using heptakis(2,3-di-O-methyl-6-O-Sulfo)-β-cyclodextrin as chiral additive – Validation using the accuracy profile strategy and estimation of uncertainty

N/A
N/A
Protected

Academic year: 2021

Partager "Enantiomeric purity testing of S-timolol by non-aqueous CE using heptakis(2,3-di-O-methyl-6-O-Sulfo)-β-cyclodextrin as chiral additive – Validation using the accuracy profile strategy and estimation of uncertainty"

Copied!
1
0
0

Texte intégral

(1)

IT'S CAOS - Abstracts

HPLC 2007

Back | Log off Home | Search in abstracts | Abstract details

Submitter | Authors | Abstract text | Graphic | Table | Grades | Presentation type

Selected abstract

Submitter Mr Roland Marini Institute University of Liege

Type Poster only

Category Chiral Analysis Title

Enantiomeric purity testing of S-timolol by non-aqueous CE using heptakis(2,3-di-O-methyl-6-O-sulfo)-β-cyclodextrin as chiral additive - Validation using the accuracy profile strategy and estimation of uncertainty

Delete | E-mail invitation

Abstract text

Type Poster only

Category Chiral Analysis

Title

Enantiomeric purity testing of S-timolol by non-aqueous CE using heptakis(2,3-di-O-methyl-6-O-sulfo)-β-cyclodextrin as chiral additive - Validation using the accuracy profile strategy and estimation of uncertainty

Text Non-aqueous capillary electrophoresis (NACE) was successfully applied to the enantiomeric purity

testing of S-timolol maleate using heptakis(2,3-di-O-methyl-6-O-sulfo)-β-cyclodextrin (HDMS-β-CD) as chiral selector. With a background electrolyte made of a methanolic solution of 0.75 M formic acid, 30 mM potassium camphorsulfonate and containing 30 mM HDMS-β-CD, the determination of 0.1% of R-timolol in S-R-timolol could be achieved with an enantioresolution of 8.5. Pyridoxine was used as internal standard. The NACE method was then fully validated by applying a novel strategy using accuracy (total error) profiles. This strategy is based on β-expectation tolerance intervals for the total measurement error which includes trueness and intermediate precision. The uncertainty of measurements derived from β-expectation tolerance intervals was estimated at each concentration level of the validation standards. To confirm the suitability of the method, several real samples of S-timolol maleate containing R-timolol maleate at different concentrations were analyzed and the results were compared to those obtained by liquid chromatography.

Link https://secure.caos.nl/hplc2007/abstract.asp?hash=cd3b2c5

Change details

Home

Tools

Configuration

Page 1 of 1

HPLC 2007

5/06/2007

https://secure.caos.nl/hplc2007/admin/viewabs.asp?id=978

Références

Documents relatifs

By this logic the barrier for rota- tion of the lateral phenyl group should be the highest for X = O (1d), but our present results show that this is not the case (the gas

Interconversion of anti atropisomer of 1d (structures from B2PLYPD/cc-pVDZ calculations; note that the two anti structures are identical); the TS 1 lies 2.82 kJ/mol higher than

• Ces familles se sont suivies (succédées) dans le temps, donne leur un numéro d’ordre de la plus lointaine (la plus ancienne=1) à la plus récente (proche de nous=4): 1, 2, 3,

We propose two types of optimization problems that allow identifying the parameters of a 2-additive bi-capacity such that the inferred bipolar Choquet integral is consistent with

Table 2-BET specific surface area values of Mont-Na before and after adsorption and.. Catalyst weight: 15 mg. Figure 2-Effect of temperature on the catalytic oxidation

We propose two types of optimization problems that allow identifying the parameters of a 2-additive bi-capacity such that the inferred bipolar Choquet integral is consistent with

To address the optimum Ac 4 GalNAz concentration for cell labeling and FRET analysis, HeLa cells were treated with increasing Ac 4 GalNAz concentration (10, 20, 50, 100 and 200,

The methyl iodide mixing ratio, [CH 3 I] saturator , shown in Table 1 was determined at the exit of the saturation system and calculated from the given temperature, vapor pressure,