• Aucun résultat trouvé

Radiosurgery with Linac and Micro Multi-Leaf Collimator (mMLC)

N/A
N/A
Protected

Academic year: 2021

Partager "Radiosurgery with Linac and Micro Multi-Leaf Collimator (mMLC)"

Copied!
1
0
0

Texte intégral

(1)

Radiosurgery with Linac and Micro

Multi-Leaf Collimator

(mMLC)

J. G. Villemure1, A. Pica1, P. Coucke2, R. O. Mirimano¨2 1 Department of Neurosurgery, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland 2 Department of Radiation Oncology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland

Objective: To determine the e½cacy, advantages and disadvantages

of radiosurgery using on one hand circular collimators and on the other hand a Micro Multi-leaf collimator.

Material and Method: Between 1993 and 1999, 95 patients were treated at the CHUV with Linac radiosurgery (Varian 6 MV). Since November 1999, another Linac (Siemens Primus 6 MV) has been equipped with a Micro Multi-leaf Collimator (M3-BrainLab) allowing conformal treatments, and 33 patients have been treated with this equipment. Lesions treated were AVM, acoustic schwannomas, meningiomas, metastases, pituitary tumors, hemangioblastomas, small gliomas.

Results: The e½cacy of treatment cannot be commented strictly,

considering the short follow-up using the new technology. However, compared to previous technology available at the CHUV, M3 with

its hardware and software, provides a more homogeneous dose distribution in oddly shaped lesions, a reduction in the time invested in

planning, the possibility of fractionated treatment using mask immobilization. Software allows CT, MRI, angio images fusion, projection

of isodose curves, 3D visualization of lesion and isodose distribution, quantitative evaluation of target volume and critical structures

(Dose Volume Histograms, DVH), and simulation of treatment. Conclusion: Compared with the previous technology using circular collimators, the new Micro Multi-leaf Collimator has allowed to treat more complex lesions, to use fusion techniques of images, a more precise de®nition of the volume, and less time invested in planning the treatment. The possibility of fractionated treatments o¨ers clear radiobiological advantages in some lesions compared to radiosurgery. Conformal treatments and homogeneous dose distribution, characteristic of the technology using the Micro Multi-leaf

Références

Documents relatifs

first demonstrated that the accuracy of the reconstructed image obtained by CACAO, will be potentially better than those obtained using the thin hole collimator technic.

data (b) and the minimum solution Az min allows to sort the negative errors.. The same hold for the positive errors with

The leaf contains some of the most important features used in a plant identification task: leaf type (simple or compound), shape, color, texture, venation and margin.. Furthermore,

Congrès 2015 Société Française de Thermique: ”La thermique de l’habitat et de la ville”, May 2015, La Rochelle, France..

Dans ce travail, une approche multi-échelle a été développée pour simuler les transferts dans des micro-conduites de grande extension en tirant avantage d’une

Like the design of antagonistic pre-shaped double beams, to solve the asymmetrical output force problem, a gap for pre-load is defined between bistable mechanism part

The structure proposed for this study is a complete solar to hydrogen conversion system comprising multi-junction solar cells with appropriated Fresnel lenses for

In this section, we illustrate the ability of AA4MM to describe and simulate a multi- model composed of different formalisms (with individual-based, equation-based and