• Aucun résultat trouvé

THz QCL - Based active imaging applied to composite materials diagnostic

N/A
N/A
Protected

Academic year: 2021

Partager "THz QCL - Based active imaging applied to composite materials diagnostic"

Copied!
2
0
0

Texte intégral

(1)

This is an author-deposited version published in:

http://oatao.univ-toulouse.fr/

Eprints ID: 2875

To cite this document:

DESTIC, Fabien. PETITJEAN, Yoann. SIRTORI, Carlo.

BARBIERI, Stefano. MOLLIER, Jean-Claude. THz QCL - based active imaging

applied to composite materials diagnostic. In: The 34th international conference on

Infrared, Millimeter and Terahertz Waves, 21-25 Sept 2009, Busan, Corée du sud.

Any correspondence concerning this service should be sent to the repository

administrator:

staff-oatao@inp-toulouse.fr

(2)

Abstract — This paper is a presentation of the recently

developed researches at OLIMPES laboratory in the field of active imaging using THz Quantum Cascade Laser applied to composite materials diagnostic.

I. INTRODUCTIONAND BACKGROUND

his paper describes the recently developed works conducted at OLIMPES, a laboratory resulting from a collaboration between ISAE and ONERA/DOTA. The experimental setup is based on a Quantum Cascade Laser (QCL) as a source and a NTD-Ge bolometer as a detector. One of our objectives is to perform materials diagnostics, both in transmission and reflection, at various frequencies in the 1 - 5 THz range. Many works have been conducted about THz imaging of various objects or materials hidden behind or into different materials: plastics in powdered sugar [1], weapon behind clothes [2], ink inside an envelope [3] are some well known examples. As we know, composite materials diagnostic with the help of THz waves has not yet been investigated.

II. RESULTS

The experimental setup used is shown below.

Figure 1: Experimental setup

The QCL is driven by an ILX Lightwave LDP3840P pulsed current source (Duty Cycle = 1%, Pulse Width = 60 µs). A peak power close to 1 mW at 2.3 THz is available at the output of the cryostat. The emitted beam is then collected by a set of four off-axis parabolic mirrors (OAPM) that allow us to focus it on the sample to be imaged. The object is moved in X and Y

by two motorized translation stages. The signal from the NTD-Ge bolometer (QMC Instruments Ltd., NEP = 2.8 pW.Hz-1/2) is acquired via an EG&G SR5209 lock-in amplifier. As an illustration, the raw image of a key and a plastic ruler (fig. 2), hidden behind a cardboard sheet, is presented in figure 2. The image (size = 31 x 31 points) is obtained with a 2 mm step both in X and Y. The Signal-to-Noise Ratio is estimated to 70.

a) object b) 2.3 THz image

Figure 2: Image of a key hidden behind a cardboard sheet

The first experiments on composite materials (Kevlar, glass fibre, carbon fibre …) have shown that some of them can be “transparent” to THz waves. We are now studying the transmission through various materials with specific qualities and different mesh sizes. Work is in progress to use THZ transmission imaging to detect defaults or damages caused by an impact in the composite materials structure.

The authors wish to thank Pr. Carlo SIRTORI and Stefano BARBIERI for their supply of QCLs.

REFERENCES

[1] Hermann et al. “Terahertz imaging of objects in powders”, Optoelectronics, IEE Proceedings, 2002, vol.149, pp116-120 [2] Jacobs et al. “Concealed weapon identification using terahertz imaging

sensors” Terahertz for Military and Security Applications IV, SPIE, 2006, 6212, 62120J

[3] Lee et al. “Real-time imaging using a 4.3-THz quantum cascade laser and a 320 x 240 microbolometer focal-plane array”,Photonics Technology Letters, 2006, vol.18, pp 1415-1417

Fabien Destic

a

, Yoann Petitjean

a

and Jean-Claude Mollier

a,b

a

Université de Toulouse, ISAE - OLIMPES, Toulouse, France

b

ONERA / DOTA , Toulouse, France

THz QCL - based active imaging

applied to composite materials diagnostic

Références

Documents relatifs

The research has been funded by the Walloon Region under the agreement no 1410246-STOMMMAC (CT-INT 2013- Wu Ling, Adam Laurent (e-Xstream), Noels

Thus, two experiments are used: the inversed perforation test based on the Hopkinson bar measurement technique, and the direct perforation test coupled with digital

Steady state Figure 4 c) shows the spectrum of the sound produced by Modalys for the open loop and closed loop cases, when the damping of mode 1 is controlled (the damp- ing is 3

L’accès à ce site Web et l’utilisation de son contenu sont assujettis aux conditions présentées dans le site LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D’UTILISER CE SITE

In a first line of research, we investigated how time may become an explicit conscious content by showing that temporal order is a psychological bias, which is stable over

a - Fonds documentaire de recherche sur la ville : La démarche amorcée avec la cartothèque de l'Ecole d'Architecture de Grenoble a pointé I*évidente né­ cessité de

Isolation of Nontuberculous Mycobacteria in Southeast Asian and African Human Immunodeficiency Virus-infected Children With Suspected Tuberculosis... Clinical

The synthesized 2,1-benzisoxazoles 1–12 were evaluated for their in vitro antibacterial activity against representative Gram-positive (Bacillus subtilis, Staphylococcus aureus)