• Aucun résultat trouvé

Configuration Worksheet VIII. Data Communications

Dans le document HP 3000 SYSTEMS (Page 80-87)

General 1/0 Channels

Series 42 Configuration Worksheet VIII. Data Communications

A. Workstations, Plotters, and Printers (Enter quantities in lines below):

NOT E: Cabling must be Connection Method

ordered separately for

these devices! Pt-to-Pt with ATP or ADCC

Direct Connect

Daisychain* ADCC/ATP ATP ADCC/ATP

Product Multipoint Modem Type 422 Type 232-C Display Terminals

239x N/A*

2623A N/A*

2624B

-2625A 2626A

2626W N/A**

2627A N/A*

2628A

Plotters

7440A N/A N/A

7470A N/A N/A

7475A N/A N/A

7510A N/A N/A

7550A N/A N/A

7570A N/A N/A

7580A/B N/A N/A

7585A/B N/A N/A

7586B N/A N/A

Data Collection Terminals

3075A N/A

3076A N/A

3077A N/A

3081A N/A

Subtotal (this page) 18A 19A 20A 21A

* The 2333A and 2334A Cluster Controller will support any RS-232-C device except the 2635B and 2382A.

** 2626W works as a multipoint terminal but not with HPWORD.

Terminal Attached

N/A N/A N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A

22A

Series 42 Configuration Worksheet

Subtotal (this page)

Subtotal (previous page)

Totals (both pages)

* The 2333A and 2334A Cluster Controller will support any RS-232-C device except the 2635B and 2382A.

** Note device maximums in Section VI of the worksheet.

Product Number

Series 42 Configuration Worksheet

Description

B. ATP Advanced Terminal Processors

The Series 42 supports one (1) ATP Expansion Package for ATP support.

Either the 3027 3A Direct Connect A TP Expansion Package or the 30274A Modem Connect Expansion Package can be used. Each includes thuir~Dire~ Conne~ or ModeqLPort ControlleL(Ltpor~

Qlus on~~steml!lterfac~oard~SIB). Additional Port Controllers may be ordered for the Series 42 up to the following maximum combinations which include the initial 12 ports: 1) Maximum of four Direct

Connect Port Controllers; 2) Maximum of two Direct Connect Port Controllers with one Modem Port Controller; 3) Maximum of two Modem Port Controllers.

Step #1:

Determine the number of A TP modem ports needed from line 1 9

Quantity

(MAX=24). 23A

Determine the number of ATP direct connect ports needed (Sum of line

20 and line 21 (MAX=48)). 23B _ _ _ _ _

(N ote: The above maximums may not be reached simultaneously.)

Step #2:

Determine what products you should order using the following table.

Select the appropriate column and row corresponding to your modem and direct connect port requirements and order the products indicated at their intersection. (Unused modem ports may be used for RS-232-C direct connections.)

Product Number

30274A

301SSA

30273A

3014SA

Series 42 Configuration Worksheet

Description Quantity

ATP Direct ATP Modem Port Controllers Required Connect Port

Con trollers 0 1 2

Required (0 ports) (up to 12 ports) (up to 24 ports)

0 1 30274A 1 30274A

(0 ports) 1 Opt. 042 1 Opt. 042

1301SSA 1 Opt. 042

1 1 30273A 1 30274A

(up to 12 ports) 1 Opt. 042 1 Opt. 042 Not

1 3014SA Supported

1 Opt. 042

2 1 30273A 1 30274A

(up to 24 ports) 1 Opt. 042 1 Opt. 042 Not

1 3014SA 23014SA Supported

1 Opt. 042 2 Opt. 042

3 1 30273A

(up to 36 ports) 1 Opt. 042 Not Not

23014SA Supported Supported

2 Opt. 042

4 1 30273A

(up to 48 ports) 1 Opt. 042 Not Not

330145A Supported Supported

3 Opt. 042

*

Note that additional direct connect and modem ports may be connected using the ADCC. (See Section C.)

Modem Connect ATP Expansion Package (Option 042) includes 12 modem ports and one SIB. (MAX=

O.

ATP Modem Port Controller provides 12 RS-232 modem ports (Option 042).

Direct Connect ATP Expansion Package (Option 042) includes 12 RS-422 ports and one SIB. (MAX=1).

A TP Direct Connect Port Controller provides 12 RS-422 ports (Option 042).

24A

24B

24C

24D

MARCH 87 1-71

Product Number

30018A

30019A

Series 42 Configuration Worksheet

Description

Step #3:

For each 3027 3A and 3014 SA ordered above, you must order the appropriate number of Options 002 in order to obtain the right mix of RS-232-C versus RS-422 ports from line 20. Each Direct Connect Port Controller and Expansion Package comes standard with 12 RS-422 terminal connections. They are converted to RS-232 connections in groups of four by ordering Option 002 as indicated in the matrix below:

For each 30273A or 30145A (24C and 24D):

# Options 002

o

1 2 3

Total Option 002s

# RS-422 ports 12

8 4

o

# RS-232-C ports

o

4 8 12

C. ADCC Asynchronous Data Communications Controller

If you require more than 24 modem ports or more than 48 direct connect ports, you must order the ADCC. At~ minimuI!hYf}!Lmust orde:r..9neJJ..L ADCC -Mai~ to su J2.Ror.1JhuY~Jen.Lconsole;jJ~annot be

~l.D2.l2orte<L.9lLth~ATP.

ADCC ports required (Total of lines 19 and line 21 minus the number of RS-232-C ATP ports configured (line 24E multiplied by "4") and modem ATP ports configured (lines 24A and 24B multiplied by 1112")).

Quantity

24E _ _ _ _ _

If zero, enter II 1" for System Console. 25 Total ADCC-Main and ADCC-Extender cards required (Divide line 25 by "4" and round up to the nearest integer; MIN=l; MAX=8) 26 ADCC-Main (Divide line 26 by "2" and round up to the nearest integer;

internal cables included with Option 040; external cables for devices must be ordered separately.)

ADCC-Extender (line 26 minus line 27) (Internal cables included with Option 040; external cables for devices must be ordered separately.)

27

28

Product Number

30079A

Series 42 Configuration Worksheet

Description Quantity

IX. Network Links (INPs).

HP to HP System Lines (30270A, 30271A, 32187A, 32188A) 29A

HP to IBM System Lines (30246A, 30251A) 29B

Multipoint Lines (32026A, 32027A, 32028A) 29C

Local Area Network (30242A) (MAX=!) 29D

Total number of Links (lNPs) (Sum of lines 29A, 29B, and 29C;

MAX=3)* 29

* Additional Links without hardware (Option 390) may be supported.

X. 1/0 Expansion.

A. General 1/0 Channels (GICs)

To determine the number of GICs required on the system, refer to the discussion on GICs in the Series 42 maximum system configuration section of this chapter.

(Note: To configure GICs you must take into consideration .peripheral speed, electrical device loads, cable lengths, peripheral incompatibilities and system performance. These are discussed in detail in the Chapter One Appendix.)

A figure showing four (4) GICs has been included in the GIC section of this chapter for your use as a configuration worksheet.

Optional GICs (MAX=2). Two GICs are shipped standard with a new system order; box swap upgrade systems do not include the two standard GICs. Internal cables are included by ordering Option 040; external HP-IB cables are supplied with devices unless otherwise indicated.

B. Junction Mounting Panels

The Series 42 SPU only requires junction mounting panels when ATPs are configured. The ATP Expansion Package provides sufficient space on its junction mounting panel for the supported ATP configurations.

30

MARCH 87 1-73

Product Number

Series 42 Configuration Worksheet

Description Quantity

C. 1/0 Card Slots The sum of:

Line 12C -- 261x Line Printer Interface 31A

Line 29 -- Network Links (INPs) 31B

Line 26 -- ADCC Cards 31C

Line 24B -- Modem Port Controllers (AIBs) 31D

Line 24D -- Direct Connect Port Controllers (AIBs) 31E Port Controller provided with ATP Expansion Package (line 24A or

line 24C) 31 F

One SIB provided with ATP Expansion Package

(Enter zero (0) if both Line 31 D and Line 31 E are blank; otherwise,

enter one (1),) 31G

Line 30 -- Optional GICs 31H

Standard GICs (2) 311

Line 29D - LANIC 31J

Total of Lines 31 x; MAX= 13 31

Dans le document HP 3000 SYSTEMS (Page 80-87)

Documents relatifs