• Aucun résultat trouvé

1.06

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-032 (SED) - Average jeudi 9 mai 2019 16:19:23

12.465 µm

Moyenne :

Date de l'analyse :

m²/g 27.548 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 65.17%

Percentage between 0.02 µm and 200.00 µm : 98.35%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 8.23%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 90.65%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 8.23%

Percentage between 200.00 µm and 2000.00 µm : 1.65%

Percentage between 2.00 µm and 20.00 µm : 56.94%

Percentage between 20.00 µm and 50.00 µm : 22.08%

Percentage between 50.00 µm and 200.00 µm : 11.11%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

2895.51

Percentage between 63.00 µm and 200.00 µm : 7.70%

Percentage between 20.00 µm and 63.00 µm : 25.49%

15.892 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 36.89 30.000 76.79 150.000 97.90 500.000 99.84 1500.000 100.00

1.000 2.24 10.000 43.25 40.000 83.25 200.000 98.35 600.000 100.00 2000.000 100.00

2.000 8.23 15.000 55.92 50.000 87.24 250.000 98.51 800.000 100.00

2.500 11.44 16.000 58.01 63.000 90.65 300.000 98.72 900.000 100.00

4.000 20.15 20.000 65.17 100.000 95.71 400.000 99.32 1000.000 100.00

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-032 (SED) - Average jeudi 9 mai 2019 16:19:23

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 16:30:28 Record Number: 75 File name: 0905

Annexe au rapport d'analyse

0.748

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-033 (SED) - Average jeudi 25 avril 2019 16:18:06

25.010 µm

Moyenne :

Date de l'analyse :

m²/g 95.809 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 43.58%

Percentage between 0.02 µm and 200.00 µm : 90.64%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 5.60%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 79.96%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 5.60%

Percentage between 200.00 µm and 2000.00 µm : 9.36%

Percentage between 2.00 µm and 20.00 µm : 37.98%

Percentage between 20.00 µm and 50.00 µm : 29.80%

Percentage between 50.00 µm and 200.00 µm : 17.26%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

59034.087

Percentage between 63.00 µm and 200.00 µm : 10.68%

Percentage between 20.00 µm and 63.00 µm : 36.38%

36.777 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 24.32 30.000 55.89 150.000 90.03 500.000 94.04 1500.000 99.40

1.000 1.59 10.000 28.42 40.000 65.90 200.000 90.64 600.000 95.02 2000.000 100.00

2.000 5.60 15.000 36.63 50.000 73.39 250.000 91.16 800.000 96.59

2.500 7.66 16.000 38.08 63.000 79.96 300.000 91.73 900.000 97.20

4.000 13.27 20.000 43.58 100.000 87.80 400.000 92.92 1000.000 97.73

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-033 (SED) - Average jeudi 25 avril 2019 16:18:06

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

26/04/2019 09:41:08 Record Number: 140 File name: 2504

Annexe au rapport d'analyse

1.1

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-034 (SED) - Average jeudi 9 mai 2019 16:35:22

12.014 µm

Moyenne :

Date de l'analyse :

m²/g 27.687 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 66.60%

Percentage between 0.02 µm and 200.00 µm : 97.93%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 8.51%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 91.92%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 8.51%

Percentage between 200.00 µm and 2000.00 µm : 2.07%

Percentage between 2.00 µm and 20.00 µm : 58.09%

Percentage between 20.00 µm and 50.00 µm : 22.27%

Percentage between 50.00 µm and 200.00 µm : 9.06%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

3598.051

Percentage between 63.00 µm and 200.00 µm : 6.01%

Percentage between 20.00 µm and 63.00 µm : 25.32%

15.968 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 37.78 30.000 78.48 150.000 97.51 500.000 99.65 1500.000 100.00

1.000 2.39 10.000 44.30 40.000 85.01 200.000 97.93 600.000 99.94 2000.000 100.00

2.000 8.51 15.000 57.20 50.000 88.87 250.000 98.16 800.000 100.00

2.500 11.77 16.000 59.32 63.000 91.92 300.000 98.43 900.000 100.00

4.000 20.62 20.000 66.60 100.000 95.90 400.000 99.08 1000.000 100.00

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-034 (SED) - Average jeudi 9 mai 2019 16:35:22

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 16:57:42 Record Number: 78 File name: 0905

Annexe au rapport d'analyse

1.03

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-035 (SED) - Average jeudi 9 mai 2019 17:02:12

13.495 µm

Moyenne :

Date de l'analyse :

m²/g 25.950 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 63.49%

Percentage between 0.02 µm and 200.00 µm : 98.75%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 7.83%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 91.81%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 7.83%

Percentage between 200.00 µm and 2000.00 µm : 1.25%

Percentage between 2.00 µm and 20.00 µm : 55.66%

Percentage between 20.00 µm and 50.00 µm : 25.01%

Percentage between 50.00 µm and 200.00 µm : 10.24%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

2016.9

Percentage between 63.00 µm and 200.00 µm : 6.93%

Percentage between 20.00 µm and 63.00 µm : 28.32%

18.632 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 34.46 30.000 76.74 150.000 98.08 500.000 99.98 1500.000 100.00

1.000 2.31 10.000 40.68 40.000 84.18 200.000 98.75 600.000 100.00 2000.000 100.00

2.000 7.83 15.000 53.53 50.000 88.50 250.000 99.02 800.000 100.00

2.500 10.73 16.000 55.74 63.000 91.81 300.000 99.23 900.000 100.00

4.000 18.65 20.000 63.49 100.000 96.06 400.000 99.66 1000.000 100.00

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-035 (SED) - Average jeudi 9 mai 2019 17:02:12

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 17:04:07 Record Number: 81 File name: 0905

Annexe au rapport d'analyse

0.899

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-036 (SED) - Average jeudi 9 mai 2019 17:08:13

17.440 µm

Moyenne :

Date de l'analyse :

m²/g 40.902 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 54.04%

Percentage between 0.02 µm and 200.00 µm : 96.33%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 6.78%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 83.22%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 6.78%

Percentage between 200.00 µm and 2000.00 µm : 3.67%

Percentage between 2.00 µm and 20.00 µm : 47.25%

Percentage between 20.00 µm and 50.00 µm : 24.68%

Percentage between 50.00 µm and 200.00 µm : 17.61%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

4943.887

Percentage between 63.00 µm and 200.00 µm : 13.11%

Percentage between 20.00 µm and 63.00 µm : 29.18%

22.122 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 30.19 30.000 66.02 150.000 94.58 500.000 99.72 1500.000 100.00

1.000 1.90 10.000 35.28 40.000 73.64 200.000 96.33 600.000 99.97 2000.000 100.00

2.000 6.78 15.000 45.71 50.000 78.71 250.000 97.26 800.000 100.00

2.500 9.40 16.000 47.52 63.000 83.22 300.000 97.93 900.000 100.00

4.000 16.55 20.000 54.04 100.000 90.38 400.000 99.01 1000.000 100.00

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-036 (SED) - Average jeudi 9 mai 2019 17:08:13

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 17:11:23 Record Number: 84 File name: 0905

Annexe au rapport d'analyse

0.738

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-037 (SED) - Average jeudi 25 avril 2019 14:35:10

25.210 µm

Moyenne :

Date de l'analyse :

m²/g 84.236 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 43.11%

Percentage between 0.02 µm and 200.00 µm : 92.53%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 5.41%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 80.76%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 5.41%

Percentage between 200.00 µm and 2000.00 µm : 7.47%

Percentage between 2.00 µm and 20.00 µm : 37.70%

Percentage between 20.00 µm and 50.00 µm : 30.83%

Percentage between 50.00 µm and 200.00 µm : 18.59%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

49616.724 Variance :

µm² 222.748

Rapport moyenne/mediane : 3.341 µm

Percentage between 63.00 µm and 200.00 µm : 11.77%

Percentage between 20.00 µm and 63.00 µm : 37.65%

36.591 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 23.70 30.000 55.85 150.000 91.77 500.000 95.33 1500.000 99.51

1.000 1.57 10.000 27.75 40.000 66.20 200.000 92.53 600.000 95.99 2000.000 100.00

2.000 5.41 15.000 35.98 50.000 73.93 250.000 93.05 800.000 97.07

2.500 7.40 16.000 37.46 63.000 80.76 300.000 93.55 900.000 97.57

4.000 12.85 20.000 43.11 100.000 89.13 400.000 94.51 1000.000 98.02

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-037 (SED) - Average jeudi 25 avril 2019 14:35:10

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

25/04/2019 19:12:16 Record Number: 107 File name: 2504

Annexe au rapport d'analyse

0.923

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-038 (SED) - Average jeudi 9 mai 2019 17:13:26

17.824 µm

Moyenne :

Date de l'analyse :

m²/g 32.171 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 53.41%

Percentage between 0.02 µm and 200.00 µm : 98.17%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 7.12%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 88.81%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 7.12%

Percentage between 200.00 µm and 2000.00 µm : 1.83%

Percentage between 2.00 µm and 20.00 µm : 46.29%

Percentage between 20.00 µm and 50.00 µm : 29.80%

Percentage between 50.00 µm and 200.00 µm : 14.95%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

2788.664

Percentage between 63.00 µm and 200.00 µm : 9.35%

Percentage between 20.00 µm and 63.00 µm : 35.40%

30.844 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 30.41 30.000 66.74 150.000 97.56 500.000 99.88 1500.000 100.00

1.000 2.06 10.000 35.36 40.000 76.48 200.000 98.17 600.000 100.00 2000.000 100.00

2.000 7.12 15.000 45.25 50.000 83.21 250.000 98.51 800.000 100.00

2.500 9.75 16.000 46.98 63.000 88.81 300.000 98.84 900.000 100.00

4.000 16.84 20.000 53.41 100.000 95.40 400.000 99.46 1000.000 100.00

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-038 (SED) - Average jeudi 9 mai 2019 17:13:26

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 17:18:02 Record Number: 87 File name: 0905

Annexe au rapport d'analyse

0.707

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-039 (SED) - Average jeudi 9 mai 2019 17:20:20

25.355 µm

Moyenne :

Date de l'analyse :

m²/g 55.557 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 42.89%

Percentage between 0.02 µm and 200.00 µm : 93.69%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 5.06%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 74.30%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 5.06%

Percentage between 200.00 µm and 2000.00 µm : 6.31%

Percentage between 2.00 µm and 20.00 µm : 37.83%

Percentage between 20.00 µm and 50.00 µm : 26.39%

Percentage between 50.00 µm and 200.00 µm : 24.40%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

5993.766 Variance :

µm² 77.419

Rapport moyenne/mediane : 2.191 µm

Percentage between 63.00 µm and 200.00 µm : 19.38%

Percentage between 20.00 µm and 63.00 µm : 31.41%

27.124 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 22.56 30.000 55.19 150.000 89.68 500.000 99.93 1500.000 100.00

1.000 1.50 10.000 26.56 40.000 63.61 200.000 93.69 600.000 100.00 2000.000 100.00

2.000 5.06 15.000 35.24 50.000 69.29 250.000 96.11 800.000 100.00

2.500 6.95 16.000 36.84 63.000 74.30 300.000 97.64 900.000 100.00

4.000 12.17 20.000 42.89 100.000 82.89 400.000 99.29 1000.000 100.00

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-039 (SED) - Average jeudi 9 mai 2019 17:20:20

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 18:17:46 Record Number: 90 File name: 0905

Annexe au rapport d'analyse

1.03

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-040 (SED) - Average jeudi 9 mai 2019 17:33:28

13.505 µm

Moyenne :

Date de l'analyse :

m²/g 28.309 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 62.66%

Percentage between 0.02 µm and 200.00 µm : 98.24%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 7.85%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 90.28%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 7.85%

Percentage between 200.00 µm and 2000.00 µm : 1.76%

Percentage between 2.00 µm and 20.00 µm : 54.80%

Percentage between 20.00 µm and 50.00 µm : 24.15%

Percentage between 50.00 µm and 200.00 µm : 11.43%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

2557.276

Percentage between 63.00 µm and 200.00 µm : 7.95%

Percentage between 20.00 µm and 63.00 µm : 27.63%

18.957 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 35.19 30.000 75.24 150.000 97.39 500.000 99.93 1500.000 100.00

1.000 2.16 10.000 41.17 40.000 82.47 200.000 98.24 600.000 100.00 2000.000 100.00

2.000 7.85 15.000 53.30 50.000 86.81 250.000 98.69 800.000 100.00

2.500 10.91 16.000 55.37 63.000 90.28 300.000 99.03 900.000 100.00

4.000 19.26 20.000 62.66 100.000 95.06 400.000 99.59 1000.000 100.00

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-040 (SED) - Average jeudi 9 mai 2019 17:33:28

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 17:36:14 Record Number: 93 File name: 0905

Annexe au rapport d'analyse

0.408

Opérateur :

Moyenne de 2 mesures Résultat de la source : Référence de l'échantillon (Matrice) :

PKB8

19e049050-041 (SED) - Average jeudi 9 mai 2019 17:42:44

230.634 µm

Moyenne :

Date de l'analyse :

m²/g 459.336 µm

Surface spécifique : Données statistique

P article Size Distribution

0.01 0.1 1 10 100 1000

Percentage between 0.02 µm and 20.00 µm : 19.94%

Percentage between 0.02 µm and 200.00 µm : 48.07%

Percentage between 0.02 µm and 2000.00 µm : 100.00%

Percentage between 0.02 µm and 2.00 µm : 3.45%

µm Pourcentages cumulés :

Percentage between 0.02 µm and 63.00 µm : 31.90%

Pourcentages relatifs :

Percentage between 0.02 µm and 2.00 µm : 3.45%

Percentage between 200.00 µm and 2000.00 µm : 51.93%

Percentage between 2.00 µm and 20.00 µm : 16.49%

Percentage between 20.00 µm and 50.00 µm : 9.20%

Percentage between 50.00 µm and 200.00 µm : 18.93%

P article Size Distribution

0.01 0.1 1 10 100 1000

Médiane : Ecart type :

252086.063

Percentage between 63.00 µm and 200.00 µm : 16.17%

Percentage between 20.00 µm and 63.00 µm : 11.96%

1006.122 Mode :

µm

Size (µm) Vol Under % Size (µm) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under % Size (µm) Vol Under % Size (µ m) Vol Under %

0.020 0.00 8.000 11.68 30.000 23.82 150.000 44.08 500.000 62.15 1500.000 95.45

1.000 1.32 10.000 13.57 40.000 26.72 200.000 48.07 600.000 66.37 2000.000 100.00

2.000 3.45 15.000 17.24 50.000 29.14 250.000 51.09 800.000 74.79

2.500 4.36 16.000 17.84 63.000 31.90 300.000 53.60 900.000 78.78

4.000 6.76 20.000 19.94 100.000 38.21 400.000 57.98 1000.000 82.48

Size (µm)

Indice de réfraction :

secondes

EUROFINS Analyses pour l’Environnement France - Site de Saverne 5, rue d'Otterswiller 67700 SAVERNE -

Telephone 03 88 911 911 - Fax : 03 88 91 65 31 - Site Web : www.eurofins.fr/env SAS au capital de 1 632 800 € - APE 7120B - RCS Saverne 422 998 971

Durée d'analyse : Préparateur Hydro MU

Gamme de mesure :

Malvern Mastersizer 2000

Vitesse de la pompe :

Malvern Application 5.60

- L'alignement du laser est effectué avant chaque mesure

Water

prestation réalisée sur le site de SAVERNE

*

NF EN ISO/IEC 17025:2005 COFRAC 1-1488

S e u l e s c e r t a i n e s p r e s t a t i o n s r a p p o r t é e s d a n s c e d o c u m e n t s o n t c o u v e r t e s p a r l ' a c c r é d i t a t i o n . E l l e s s o n t i d e n t i f i é e s p a r l e s y m b o l e *

LS08F : Granulométrie laser a pas variable

Méthode interne T-PS-WO22915

2 X 19e049050-041 (SED) - Average jeudi 9 mai 2019 17:42:44

Tel := +[44] (0) 1684-892456 Fax +[44] (0) 1684-892789 Malvern, UK

Malvern Instruments Ltd.

Serial Number : MAL1064835 Mastersizer 2000 Ver. 5.60

09/05/2019 17:47:32 Record Number: 96 File name: 0905

Annexes

198

Dossier d’autorisation environnementale – Projet de réaménagement de la partie Est du port du Crouesty et de l’interface ville-port (Arzon, 56)

Annexe 3 : Planning d’exploitation Solvador Atlantique en charge du site ICPE du Tohannic (2020-2022)

Documents relatifs