[PDF] Top 20 Positive pressure ventilation for high-rise buildings

Has 10000 "Positive pressure ventilation for high-rise buildings" found on our website. Below are the top 20 most common "Positive pressure ventilation for high-rise buildings".

Positive pressure ventilation for high-rise buildings

Positive pressure ventilation for high-rise buildings

... POSITIVE PRESSURE VENTILATION FOR HIGH-RISE BUILDING ...ABSTRACT Positive pressure ventilation (PPV) is achieved by placing fans outside a building and ... Voir le document complet

98

Continuous positive airway pressure ventilation with helmet in infants under 1 year

Continuous positive airway pressure ventilation with helmet in infants under 1 year

... It is noteworthy that PCO 2 improved in only 4 out of 17 patients, raising questions about the occurrence of CO 2 rebreathing during helmet CPAP. Significant CO 2 rebreathing has been observed in adults for fresh ... Voir le document complet

5

Envelope air pressure design load: an approach for hygrothermal analysis of retrofitted high-rise masonry wall assemblies

Envelope air pressure design load: an approach for hygrothermal analysis of retrofitted high-rise masonry wall assemblies

... (2001) for tall residential and office ...made for the parametric analysis is the airtightness of the retrofit option ...fice buildings show that a typical airtightness in- crease of 43% at 50 Pascal ... Voir le document complet

13

Building envelope summary: hygrothermal assessment of systems for mid-rise wood buildings: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

Building envelope summary: hygrothermal assessment of systems for mid-rise wood buildings: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

... a ventilation pipe (which in this case consisted of a 114 mm ...tested for water ...the ventilation pipe and ...rates for which water was sprayed directly above the ...several pressure ... Voir le document complet

64

Acoustics: sound insulation in mid-rise wood buildings: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

Acoustics: sound insulation in mid-rise wood buildings: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

... a high degree of precision and repeatability. For all airborne tests, the sound pressure levels are sampled at a minimum of 9 positions in each room (which exceeds the minimum of 5 required by the ... Voir le document complet

328

Pressure differences caused by chimney effect in three high buildings and Building pressures caused by chimney action and mechanical ventilation

Pressure differences caused by chimney effect in three high buildings and Building pressures caused by chimney action and mechanical ventilation

... For the publisher’s version, please access the DOI link below./ Pour consulter la version de l’éditeur, utilisez le lien DOI ci-dessous. https://doi.org/10.4224/40000444 Access and use of this website and the ... Voir le document complet

25

Use of hygrothermal numerical modeling to identify optimal retrofit options for high-rise buildings

Use of hygrothermal numerical modeling to identify optimal retrofit options for high-rise buildings

... aging high-rise building stock will require some sort of building envelope retrofit in the near future to enhance and extend service ...and high buildings is the premature degradation of the ... Voir le document complet

8

Smoke movement in high-rise buildings

Smoke movement in high-rise buildings

... as for apartments, and a fire occurs in one of them, the smoke leaving the fire compartment will be diluted with the air leakage flow from the other compartments before it enters the vertical shafts to upper ... Voir le document complet

7

Prospective Strategies of High-rise Buildings Siting: Assessment of Impacts from Typological and Contextual Criteria

Prospective Strategies of High-rise Buildings Siting: Assessment of Impacts from Typological and Contextual Criteria

... Several proposition of urban scheme are presented in the results of this consultancy. Some of them are proposing to replace centralism with polycentrism and to multiply urban centers in completing and improving the ... Voir le document complet

8

Air barrier systems for walls of low-rise buildings: performance and assessment

Air barrier systems for walls of low-rise buildings: performance and assessment

... Archives des publications du CNRC For the publisher’s version, please access the DOI link below./ Pour consulter la version de l’éditeur, utilisez le lien DOI ci-dessous. Access and use of this website and the ... Voir le document complet

46

Solution for mid-rise wood construction: full-scale standard fire resistance tests of wall assemblies for use in lower storeys of mid-rise buildings: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

Solution for mid-rise wood construction: full-scale standard fire resistance tests of wall assemblies for use in lower storeys of mid-rise buildings: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

... temperature in the furnace. This suggests much of the face layer of gypsum board remained in place until near the end of the test. There was a slow temperature increase at the interface between the base gypsum board ... Voir le document complet

131

Mid-rise wood constructions: specifications of mid-rise envelopes for hygrothermal assessment: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

Mid-rise wood constructions: specifications of mid-rise envelopes for hygrothermal assessment: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

... products. For example several building product suppliers have their own brand of exterior grade gypsum sheathing commonly used in commercial building construction, which features a water and mould-resistant gypsum ... Voir le document complet

23

Energy efficient ventilation for maintaining indoor air quality in large buildings

Energy efficient ventilation for maintaining indoor air quality in large buildings

... the pressure difference across it caused mainly by wind and stack ...Leaky buildings are more costly to heat and more difficult to ventilate properly than relatively airtight ...of buildings, ... Voir le document complet

7

Positive Pressure Fire Resistance Furnace

Positive Pressure Fire Resistance Furnace

... For a previous furnace operating at positive pressure 3 , a satisfactory burner was developed by merely terminating a I-in. long conically shaped with diameters of 1 1/4 in. at each end [r] ... Voir le document complet

8

Mechanisms of active laryngeal closure during non-invasive intermittent positive pressure ventilation in non-sedated lambs

Mechanisms of active laryngeal closure during non-invasive intermittent positive pressure ventilation in non-sedated lambs

... Surgery for the isolated upper airway ...mask ventilation to the isolated upper airways while the lamb was spontaneously breathing through the tracheostomy, or to perform mechanical ventilation ... Voir le document complet

31

Effect of high pressure-volume and low pressure-volume mechanical ventilation on plasmatic levels of IL-6, TNF-α,

Effect of high pressure-volume and low pressure-volume mechanical ventilation on plasmatic levels of IL-6, TNF-α,

... V T : Tidal Volume References: 1: Wolthuis EK, Vlaar AP, Choi G, Roelofs JJ, Jeffermans NP, Schultz MJ (2009) Mechanical ventilation using non- injurious ventilation settings cause lung injury in the ... Voir le document complet

1

Climatological analysis for hygrothermal performance evaluation: Mid-rise wood: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

Climatological analysis for hygrothermal performance evaluation: Mid-rise wood: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

... location for which long-term data is available (HDD18 = 6440; MI = ...damage for a given location, then Port-aux Basques is the recommended location for Zone 7 ...appropriate for a cold wet ... Voir le document complet

21

Mechanical ventilation and air pressure in houses

Mechanical ventilation and air pressure in houses

... between Ventilation System and House Ventilation air includes outdoor air supplied by mechanical ventilation, air from open windows and doors, and air infiltration through cracks and openings in the ... Voir le document complet

5

Mid-rise wood: characterization of hygrothermal properties: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

Mid-rise wood: characterization of hygrothermal properties: report to Research Consortium for Wood and Wood-Hybrid Mid-Rise Buildings

... Linear regression using all the data from the first linear part of the absorption process for the five specimens was done to derive the water absorption coefficient as: 0.0034 kg m -2 s -½ . Air Permeability The ... Voir le document complet

22

Methods for measuring air leakage in high-rise apartments

Methods for measuring air leakage in high-rise apartments

... Methods for measuring air leakage in high-rise apartments Shaw, C. Y.; Gasparetto, S.; Reardon, J. T. https://publications-cnrc.canada.ca/fra/droits L’accès à ce site Web et l’utilisation de son ... Voir le document complet

13