• Aucun résultat trouvé

[PDF] Top 20 Electrochemical determination of naloxone using molecularly imprinted poly(para-phenylenediamine) sensor

Has 10000 "Electrochemical determination of naloxone using molecularly imprinted poly(para-phenylenediamine) sensor" found on our website. Below are the top 20 most common "Electrochemical determination of naloxone using molecularly imprinted poly(para-phenylenediamine) sensor".

Electrochemical determination of naloxone using molecularly imprinted poly(para-phenylenediamine) sensor

Electrochemical determination of naloxone using molecularly imprinted poly(para-phenylenediamine) sensor

... A molecularly imprinted polymer (MIP)-based electrochemical sensor featuring an electrochemically grafted para-phenylenedia- mine functional monomer on a reduced graphene oxide-gold ... Voir le document complet

10

Electrochemical determination of naloxone using molecularly imprinted poly(para-phenylenediamine) sensor

Electrochemical determination of naloxone using molecularly imprinted poly(para-phenylenediamine) sensor

... appearance of gold oxidation peak at +0.63 V in the rGO-AuNP/SPCE, but the lack of this peak on the other two electrode surfaces, indicates the presence of gold on this electrode ...presence ... Voir le document complet

7

A molecularly imprinted sol-gel electrochemical sensor for naloxone determination

A molecularly imprinted sol-gel electrochemical sensor for naloxone determination

... an electrochemical sol-gel MIP sensor for electrochemical determination of NLX is reported for the first ...MIP sensor was fabricated using tri- ethoxyphenylsilane (TEPS) ... Voir le document complet

14

On-chip multi electrochemical sensor array platform for simultaneous screening of nitric oxide and peroxynitrite

On-chip multi electrochemical sensor array platform for simultaneous screening of nitric oxide and peroxynitrite

... Characterisation of the arrayed UMEs The geometrical features and dimensions of the fabricated ESAs were characterised using optical photography, AFM and surface profiler; while the ... Voir le document complet

10

Tentative of determination of the acidity level in room temperature ionic liquids  by electrochemical methods

Tentative of determination of the acidity level in room temperature ionic liquids by electrochemical methods

... objective of this report was then to try to evaluate the accessible level of acidity in reference ionic liquids, namely BMImNTf 2 , BMImOTf and BMImBF 4 (where BMIm = 1-butyl- 3-methylimidazolium, NTf 2 = ... Voir le document complet

1

Electrochemical synthesis of peroxomonophosphate using boron-doped diamond anodes

Electrochemical synthesis of peroxomonophosphate using boron-doped diamond anodes

... amount of oxidant electrogenerated during the electrolysis of phosphate solutions as a function of the anolyte-pH (acidic pH) and of the charge passed through during the electrolyses are shown ... Voir le document complet

9

Examples of Multi-Sensor Determination of Eruptive Source Parameters of Explosive Events at Mount Etna

Examples of Multi-Sensor Determination of Eruptive Source Parameters of Explosive Events at Mount Etna

... evaluation of exit velocities at Etna comes from the fixed-pointing near-source Doppler radar V2B at very high time resolu- tion [ 12 , 30 ...the determination of the exit velocity based on ... Voir le document complet

32

Silicate determination in sea water: toward a reagentless electrochemical method

Silicate determination in sea water: toward a reagentless electrochemical method

... phosphate determination using amperometric ...one of the few analyzers adapted for in situ silicate measurements and for profiling the water column to 1000 m ...lack of autonomy, weight and ... Voir le document complet

10

Detection of contaminants using a MEMS FAIMS sensor

Detection of contaminants using a MEMS FAIMS sensor

... As can be seen, 7 is uniformly higher when the testing concentration matches the training concentration (i.e., when the signature the detector is looking for is the o[r] ... Voir le document complet

74

Electrochemical Kinetic Study of LiFePO4 Using Cavity Microelectrode

Electrochemical Kinetic Study of LiFePO4 Using Cavity Microelectrode

... amount of conducting carbon additive is of course irrelevant for the use in a practical device, but it enables to keep a close electrical contact between particles and therefore allows stable and ... Voir le document complet

6

Electrochemical Kinetic Study of LiFePO4 Using Cavity Microelectrode

Electrochemical Kinetic Study of LiFePO4 Using Cavity Microelectrode

... step of an electrochemical ...diffusion of the reactive species (b ¼ ...change of the peak current versus the potential scan rate in a logarithm ...change of the slope observed at ... Voir le document complet

5

Using a poly-chromatic X-ray beam by moisture content and microfibril angle determination: theoretical and experimental approaches.

Using a poly-chromatic X-ray beam by moisture content and microfibril angle determination: theoretical and experimental approaches.

... Lorsque la densité de l’échantillon du bois n’est pas connue d’avance, l’estimation simultanée des proportions des phases (bois anhydre et eau), constitue un enjeu qui mérite d'être étudié. Ainsi, au quatrième chapitre ... Voir le document complet

253

Reagentless and silicate interference free electrochemical phosphate determination in seawater

Reagentless and silicate interference free electrochemical phosphate determination in seawater

... Open Archive TOULOUSE Archive Ouverte (OATAO) OATAO is an open access repository that collects the work of Toulouse researchers and makes it freely available over the web where possible. This is an ... Voir le document complet

6

Distributed sensor fusion for wire fault location using sensor clustering strategy

Distributed sensor fusion for wire fault location using sensor clustering strategy

... DIAGNOSIS USING REFLECTOMETRY For many years, a wire has been considered as a system that could be installed and run for the life of the system in which it ...victims of wear and can experience some ... Voir le document complet

20

Towards Hyper-Reduction of Cardiac Models using Poly-Affine Deformation

Towards Hyper-Reduction of Cardiac Models using Poly-Affine Deformation

... number of affine frames as degrees of freedom acting on a tetrahedral mesh ...number of vertices of V, the classical approach is to define a displacement field based on the displacement ... Voir le document complet

10

Sensor network design using genetic algorithm

Sensor network design using genetic algorithm

... consists of carrying out in parallel the evaluation of chromosomes’ ...case of our algorithm, the time limiting step is the evaluation of the objective ...size of the sensitivity matrix ... Voir le document complet

6

Noncovalent functionalization of boron nitride nanotubes using poly(2,7‐carbazole)s

Noncovalent functionalization of boron nitride nanotubes using poly(2,7‐carbazole)s

... Nicole A. Rice, 1 William J. Bodnaryk, 1 Isaac Tamblyn, 2 Zygmunt J. Jakubek, 3 Jacques Lefebvre, 2 Greg Lopinski, 3 Alex Adronov, *1 and Christa M. Homenick *2 1 McMaster University, Department of Chemistry and ... Voir le document complet

14

Fabrication of poly-3-hexylthiophene/polyethylene oxide nanofibers using electrospinning

Fabrication of poly-3-hexylthiophene/polyethylene oxide nanofibers using electrospinning

... decrease of fiber diameter is believed to be directly related to a more significant polymer compaction in the fiber: when more stretched, the poly- mer chains are more compacted in the fibers, leading to a ... Voir le document complet

9

Reliable diagnostics using wireless sensor networks

Reliable diagnostics using wireless sensor networks

... system. Sensor nodes gather and send field data, such as temperature, periodically to the Base Station ...by using multi-hop routing which is not considered energy efficient. Sensor nodes transmit data ... Voir le document complet

14

Determination of bitumen and solvents using proton N.M.R.

Determination of bitumen and solvents using proton N.M.R.

... For the publisher’s version, please access the DOI link below./ Pour consulter la version de l’éditeur, utilisez le lien DOI ci-dessous. https://doi.org/10.4224/21270193 Access and use of this website and the ... Voir le document complet

25

Show all 10000 documents...