• Aucun résultat trouvé

[PDF] Top 20 3D Magnetic Resonance Spirometry

Has 5191 "3D Magnetic Resonance Spirometry" found on our website. Below are the top 20 most common "3D Magnetic Resonance Spirometry".

3D Magnetic Resonance Spirometry

3D Magnetic Resonance Spirometry

... With 3D Magnetic Resonance (MR) Spirometry, local ventilation can be assessed by MRI anywhere in the lung while the patient is freely ...of 3D MR Spirometry advantageously allows ... Voir le document complet

13

Mapping and characterizing endometrial implants by registering 2D transvaginal ultrasound to 3D pelvic magnetic resonance images

Mapping and characterizing endometrial implants by registering 2D transvaginal ultrasound to 3D pelvic magnetic resonance images

... a Magnetic Resonance (MR) image is an important approach to improve the accuracy of diagnosis and preoperative surgery ...and 3D, ...a 3D MR data in order to transform the TVUS planar image to ... Voir le document complet

15

Comparison between 3D Supersonic Shear Wave Elastography and Magnetic Resonance Elastography: a preliminary experimental study

Comparison between 3D Supersonic Shear Wave Elastography and Magnetic Resonance Elastography: a preliminary experimental study

... as Magnetic Resonance Elastog- raphy (MRE) allow accessing the mechanical properties of human ...probe. 3D SSWE is now available but needs to be validated. We compared 3D SSWE with both 2D ... Voir le document complet

3

Globally optimized 3D SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance Imaging

Globally optimized 3D SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance Imaging

... weighted magnetic resonance imaging (MRI) using compressed ...address 3D imaging using either stacks of 2D sampling patterns or a local 3D strategy that optimizes a single sam- pling ... Voir le document complet

13

3D SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance imaging

3D SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance imaging

... for Magnetic Resonance ...for 3D imaging that allows to achieve an isotropic resolution of 600 µm in just 45 seconds, compared to a scan duration of 14 min 31 s using 4-fold accelerated parallel ... Voir le document complet

10

3D Visualization of Microvascular Networks Using Magnetic Particles: Application to Magnetic Resonance Navigation

3D Visualization of Microvascular Networks Using Magnetic Particles: Application to Magnetic Resonance Navigation

... through magnetic resonance ...therapeutic magnetic microcarriers (TMMC) steered and tracked using an upgraded MRI ...a 3D map of the local microvasculature around the tumor supports ... Voir le document complet

168

3D variable-density SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance imaging

3D variable-density SPARKLING trajectories for high-resolution T2*-weighted Magnetic Resonance imaging

... 6 Universit´e de Toulouse, France 7 Siemens Healthineers, 93210 Saint-Denis, France Abstract—We have recently proposed a new optimization algorithm called SPARKLING (Spreading Projection Algo- rithm for Rapid K-space ... Voir le document complet

12

On Single-Image Super-Resolution in 3D Brain Magnetic Resonance Imaging

On Single-Image Super-Resolution in 3D Brain Magnetic Resonance Imaging

... apply 3D super resolution (SR) tech- niques to brain magnetic resonance (MR) image ...Two 3D SR methods are considered following different trends: one recently proposed tensor-based approach ... Voir le document complet

6

On Single-Image Super-Resolution in 3D Brain Magnetic Resonance Imaging

On Single-Image Super-Resolution in 3D Brain Magnetic Resonance Imaging

... apply 3D super resolution (SR) tech- niques to brain magnetic resonance (MR) image ...Two 3D SR methods are considered following different trends: one recently proposed tensor-based approach ... Voir le document complet

5

Matching of curvilinear structures : application to the identification of cortical sulci on 3D Magnetic Resonance Brain Image

Matching of curvilinear structures : application to the identification of cortical sulci on 3D Magnetic Resonance Brain Image

... Samuel Legoupil, Houssam Fawal, Michel Desvignes, Marinette Revenu, Daniel Bloyet, Pascal Allain, Jean-Marcel Travère. To cite this version:[r] ... Voir le document complet

7

Monitoring of 3D breast carcinoma cell culture using proton magnetic resonance imaging

Monitoring of 3D breast carcinoma cell culture using proton magnetic resonance imaging

... that 3D culture in a hollow-fiber bioreactor simulates in vivo an environment which is favorable for tissue growth and simulates particularly well the spatial organization of solid tumors (Malone et ... Voir le document complet

11

Semiautomated 3D liver segmentation using computed tomography and magnetic resonance imaging

Semiautomated 3D liver segmentation using computed tomography and magnetic resonance imaging

... From the Department of Radiology, Saint-Luc Hospital, University of Montreal, 1058 rue Saint-Denis, Montreal, Quebec, Canada H2X 3J4 (A.G., K.M.-T., F.M.-R., A.T.); Department of Radiology, Montreal General Hospital, ... Voir le document complet

181

Cortical sulci model and matching from 3D brain magnetic resonance images

Cortical sulci model and matching from 3D brain magnetic resonance images

... INTRODUCTION Positron Emission Tomography (PET) is one of the most popular technique for the study of brain functional activity. Several studies as in Fox et al (1), Neelin et al (2) show that PET is an in-vivo ... Voir le document complet

6

Mapping of low flip angles in magnetic resonance.

Mapping of low flip angles in magnetic resonance.

... 3 Centro De Biofísika Médica, Universidad de Oriente, Santiago de Cuba 4 CRLCC Eugène Marquis, Rennes E-mail: fabien.balezeau@gmail.com Abstract Errors in the flip angle have to be corrected in many MRI applications, ... Voir le document complet

13

Acquisition and reconstruction methods for magnetic resonance imaging

Acquisition and reconstruction methods for magnetic resonance imaging

... In this chapter, we develop a new single-step QSM model that combines the ad- vantages of multiple SMV kernels and TV/TGV regularizations. Fast solvers for the proposed single-step model are developed based on the ... Voir le document complet

138

Parallel magnetic resonance imaging reconstruction problems using wavelet representations

Parallel magnetic resonance imaging reconstruction problems using wavelet representations

... UWR-SENSE, 3D- UWR-SENSE and 4D-UWR-SENSE algorithms outperform the mSENSE reconstruction algorithm available in the Siemens scanner ...and 3D-UWR-SENSE ...the 3D-UWR-SENSE algorithm may outperform ... Voir le document complet

209

Nuclear Magnetic Resonance Volumetric Antenna

Nuclear Magnetic Resonance Volumetric Antenna

... materials. Magnetic Resonance Imaging (MRI) experiments are designed in order to access local information on grains and liquid content, and couple mechanical measurements with microstructural information by ... Voir le document complet

6

Kerker Effect in Ultrahigh-Field Magnetic Resonance Imaging

Kerker Effect in Ultrahigh-Field Magnetic Resonance Imaging

... the magnetic field obtained in the median plane of a z-oriented thin wire of length L located in ...the magnetic field produced by the 16 birdcage legs and the four HMA wires with varying ...the ... Voir le document complet

12

Quantitative mapping of angiogenesis by magnetic resonance imaging

Quantitative mapping of angiogenesis by magnetic resonance imaging

... diameter 2.8 nm versus 0.9 nm, longitudinal relaxivity r 1 = 17.2 mM- 1 s -1 versus 2.9 mM -1 s -1 , transverse relaxivity r 2 = 27.1 mM- 1 s -1 versus 4.8 mM -1 s -1 at 2.35 T, [64]). A rapid steady state of at least ... Voir le document complet

37

Characterization of food stuffs using magnetic resonance elastography

Characterization of food stuffs using magnetic resonance elastography

... Figure 1: The pneumatic dual actuator set up. A) Removable sample holder with sam- ple(d) shown on top of the coil-insert(b) with rollers to accommodate a left-right motion caused by the actuators. B) Position of the ... Voir le document complet

21

Show all 5191 documents...