• Aucun résultat trouvé

fire behaviour.

Studies on the fire behaviour of FRP reinforced and/or strengthened concrete members

Studies on the fire behaviour of FRP reinforced and/or strengthened concrete members

... of fire behaviour of FRP-wrapped columns. Full-scale fire tests planned for this year are required to validate the numerical model for FRP wrapped columns, and to gain insight into the ...

14

Fire behaviour of hybrid filament-wound single and adhesively bonded composites tubes under static pressure

Fire behaviour of hybrid filament-wound single and adhesively bonded composites tubes under static pressure

... the fire behaviour of water-filled E glass-reinforced Vinylester 411 hybrid filament-wound composites ...of fire endurance tests have been carried-out on both single and joined com- posite ...to ...

13

Modelling the fire behaviour of FRP wrapped square reinforced concrete columns

Modelling the fire behaviour of FRP wrapped square reinforced concrete columns

... Access and use of this website and the material on it are subject to the Terms and Conditions set forth at Modelling the fire behaviour of FRP wrapped square reinforced concrete columns Chowdhury, E.U.; ...

9

Fire behaviour of FRP wrapped square reinforced concrete columns

Fire behaviour of FRP wrapped square reinforced concrete columns

... 4 Department of Civil and Environmental Engineering, Michigan State University, Michigan, USA Abstract Numerous applications of fibre reinforced polymers (FRPs) have demonstrated good performance in retrofitting and ...

3

Fire behaviour of FRP wrapped square reinforced concrete columns

Fire behaviour of FRP wrapped square reinforced concrete columns

... in fire, an experimental and analytical study is being conducted on the fire behaviour of FRP-strengthened square reinforced concrete ...analysis behaviour in numerical fire ...for ...

10

Effects of ageing on the fire behaviour of flame-retarded polymers: a review

Effects of ageing on the fire behaviour of flame-retarded polymers: a review

... Almeras et al. [52] also investigated the flame retardancy of a PP/polyamide 6 (PA6)/APP/ethylene vinyl acetate (EVA 24 ) blend before and after ageing. EVA 24 is an ethylene vinyl acetate copolymer containing 24 wt% of ...

63

Fire behaviour of electrical cables in cone calorimeter: Influence of cables structure and layout

Fire behaviour of electrical cables in cone calorimeter: Influence of cables structure and layout

... fire behaviour of various pro- ducts including cables [ 3 , 4 , 25 ...the behaviour of a series of 21 electric cables ex- hibiting the same layout but differing only by the composition of their sheath or ...

11

Preliminary investigation of the fire behaviour of a partially protected steel structure

Preliminary investigation of the fire behaviour of a partially protected steel structure

... Temperatures on each of 6 steel joists were measured by 3 thermo- couples peened into the steel at centre span and located on the cross-section as shown in Figure 5.. Unexposed surface t[r] ...

25

Modelling the fire behaviour of FRP-strengthened reinforced concrete columns

Modelling the fire behaviour of FRP-strengthened reinforced concrete columns

... Full-scale fire tests are relatively time consuming and costly to perform, and while the current study includes fire tests on insulated FRP-wrapped RC columns, it was desired to develop numerical models ...

17

Production of polymer/clay nanocomposite foams with improved fire behaviour using supercritical fluid technology

Production of polymer/clay nanocomposite foams with improved fire behaviour using supercritical fluid technology

... The aim of this work is to improve poly(styrene-co-acrylonitrile) (SAN) foams burning behaviour by adding a few percent of lamellar inorganic nanofillers of the montmorillonite type. The foams are produced either ...

1

Influence of carbon nanotubes on fire behaviour and aerosol emitted during combustion of thermoplastics

Influence of carbon nanotubes on fire behaviour and aerosol emitted during combustion of thermoplastics

... Uncertainty on thermal response parameter is determined as a function of the regression fit needed to calculate it. The association of both techniques provides additional information about the mechanisms of degradation. ...

18

Rail tank cars exposed to fire: literature review of crude oil, condensate and ethanol behaviour

Rail tank cars exposed to fire: literature review of crude oil, condensate and ethanol behaviour

... couple fire models w it h solid object models in order t o account for t he t hermal coupling of fires and engulfed object ...he-art fire models are ext remely complex in t heir ow n right , having t o ...

103

Study of the Occupants' Behaviour During the 2 Forest Laneway Fire in North York, Ontario January 6, 1995

Study of the Occupants' Behaviour During the 2 Forest Laneway Fire in North York, Ontario January 6, 1995

... In summary, for the respondents who are sure of their reported time, one person heard the alarm stop at 5:00 on the 1 lth floor; one heard it stop at 5:20 on the 16th floor; according [r] ...

95

Behaviour of single sided composite joints at room temperature and in case of fire after an earthquake

Behaviour of single sided composite joints at room temperature and in case of fire after an earthquake

... the fire tests and numerical simulations As part of the PRECIOUS project, BRE performed a series of six fire tests on sub-structures with the aim of evaluating the mechanical behaviour of extended ...

23

How to coexist with fire ants: The roles of behaviour and cuticular compounds

How to coexist with fire ants: The roles of behaviour and cuticular compounds

... red fire ant Solenopsis saevissima (Smith) and its sympatric ant species in forest edges in French Guiana, a part of its native range that extends from Suriname to northern ...invasive fire ants ...

8

Fire statistics

Fire statistics

... L’accès à ce site Web et l’utilisation de son contenu sont assujettis aux conditions présentées dans le site LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D’UTILISER CE SITE WEB. READ THESE T[r] ...

12

Fire severity: basis of fire safety design

Fire severity: basis of fire safety design

... The ventilation of the compartment is, as a rule, draft modified (Figs. If the secondary routes of communication are.. where & is the thermal inertia of the enclosure boundaries,[r] ...

39

Relationship between fire resistance and fire tolerance

Relationship between fire resistance and fire tolerance

... To develop a relationship between fire tolerance and fire resistance, first the temperature of the crucial steel component, Ts (at a distance a below the surface of t[r] ...

12

Fire investigations by the Fire Section, 1956

Fire investigations by the Fire Section, 1956

... L’accès à ce site Web et l’utilisation de son contenu sont assujettis aux conditions présentées dans le site LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D’UTILISER CE SITE WEB.. Internal Re[r] ...

30

Parametrical study on the behaviour of steel and composite cellular beams under fire conditions

Parametrical study on the behaviour of steel and composite cellular beams under fire conditions

... For both beam 1 and beam 3, the failure was due to web-post buckling near the beam supports (Figure 2), which is one of the usual modes of failure observed for such beams in fire situation.. Besides, because of ...

10

Show all 2171 documents...