• Aucun résultat trouvé

EOS Imaging

Validation of hip joint center localization methods during gait analysis using 3D EOS imaging in typically developing and cerebral palsy children

Validation of hip joint center localization methods during gait analysis using 3D EOS imaging in typically developing and cerebral palsy children

... In this study, deviations to the reference of HJC localization techniques were mostly comparable to those obtained in the literature in the case of adult subjects, using the EOS imaging technique [20] , ...

7

Assessing the accuracy and precision of manual registration of both femur and tibia using EOS imaging system with multiple views

Assessing the accuracy and precision of manual registration of both femur and tibia using EOS imaging system with multiple views

... Assessing the accuracy and precision of manual registration of both femur and tibia using EOS imaging system with multiple views K. Langlois a , H. Pillet a , F. Lavaste a , G. Rochcongar b , P. Rouch a , ...

3

The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: Prospective study with the EOS imaging system

The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: Prospective study with the EOS imaging system

... 2.2. Method of assessment All patients underwent follow-up by EOS imaging at 3 months post-operative. The protocol described by Lazennec et al. [6] and Chaibi et al. [10] was used: standing with the feet ...

6

Good vs Poor Results After Total Hip Arthroplasty: An Analysis Method Using Implant and Anatomic Parameters With the EOS Imaging System

Good vs Poor Results After Total Hip Arthroplasty: An Analysis Method Using Implant and Anatomic Parameters With the EOS Imaging System

... individually. EOS imaging can be used on all patients, because of the low dose, to analyze cup position and other functional and anatomic parameters, both preoperatively and ...

11

Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging

Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging

... low-dose EOS imaging is an innovative slot- scanning radiograph system providing valuable informa- tion in this specific ...radiograph. EOS slot-scanning radiographs are always aligned with the ...

10

2018 — Segmentation précise des structures de l'articulation du genou sur des radiographies EOS de face

2018 — Segmentation précise des structures de l'articulation du genou sur des radiographies EOS de face

... par EOS Imaging est d’aider les cliniciens à faire des ...images EOS sont donc des images de pathologies contenant de grandes variations de morphologies dans les cas d’arthroses par exemple ...

132

Évaluation des paramètres pelvi-rachidiens et de l’équilibre sagittal dans la spondylarthrite axiale avec la méthode d’imagerie EOS®

Évaluation des paramètres pelvi-rachidiens et de l’équilibre sagittal dans la spondylarthrite axiale avec la méthode d’imagerie EOS®

... criteria) and asymptomatic volunteers. Participants were classified into 3 groups: patients before anti-TNF introduction (G1, n= 43), patients already treated by anti-TNF (G2, n=35) and healthy controls (G3, n= 96). Each ...

76

Étude de la dystrophie rachidienne de croissance en imagerie EOS et de ses facteurs associés chez 97 jeunes skieurs de haut niveau

Étude de la dystrophie rachidienne de croissance en imagerie EOS et de ses facteurs associés chez 97 jeunes skieurs de haut niveau

... beginning of the study. Each subject underwent a medical examination and spinal X-ray using EOS imaging system. Backache was defined by a visual analogic scale and had to be > 3 to be considered. ...

57

EOS 3D Imaging: assessing the impact of brace treatment in adolescent idiopathic scoliosis

EOS 3D Imaging: assessing the impact of brace treatment in adolescent idiopathic scoliosis

... One of the major revolutions in the field of adolescent idiopathic scoliosis (AIS) during the past 10 years is the development of 3D imaging devices in standing position, such as EOS (EOS ...

4

Measuring extension of the lumbar-pelvic-femoral complex with the EOS® system.

Measuring extension of the lumbar-pelvic-femoral complex with the EOS® system.

... by EOS  imaging enables this sagittal analysis of both the subpelvic region and lumbar spine by combining the reference standing position and the possibility of dynamic ...

9

Two-Photon Imaging

Two-Photon Imaging

... The low diffusivity of the substances transported by the blood makes essential the presence of a large network of capillaries (4 to 8 µm in diameter) within the whole tissue volume. It is at this scale that exchanges ...

19

Computational ghost imaging

Computational ghost imaging

... in imaging; ...Ghost imaging is the acquisition of object information by means of photocurrent correlation measure- ...ghost imaging that unified prior work on biphoton and pseudother- mal ...ghost ...

3

EOS ® orthopaedic imaging system to study patellofemoral kinematics : Assessment of uncertainty

EOS ® orthopaedic imaging system to study patellofemoral kinematics : Assessment of uncertainty

... Material and methods: Eight pairs of fresh-frozen cadaver specimens with no evidence of pre- vious knee surgery were studied using a new test rig where the femur remains fixed and the tibia is free to rotate. The ...

10

Acousto-optic imaging : challenges of in vivo imaging

Acousto-optic imaging : challenges of in vivo imaging

... cousto-optic imaging allows recovering optical contrast deep inside multiply scattering ...medical imaging and the basic principle of acousto-optic ...optic imaging and commercial ultrasound ...the ...

294

Transient Wave Imaging

Transient Wave Imaging

... Using the outer asymptotic expansion, we design a time-reversal imaging tech- nique for locating the anomaly. Based on such expansions, we propose an optimiza- tion problem for recovering geometric properties as ...

88

Mesure de hauteur discale du rachis lombaire : comparaison entre radiographie standard et un système radiographique à balayage EOS®

Mesure de hauteur discale du rachis lombaire : comparaison entre radiographie standard et un système radiographique à balayage EOS®

... Matériels et Méthodes: 50 patients atteints de lombalgie chronique ont été inclus de manière consécutive, prospective, dans cette étude monocentrique. Tous avaient des acquisitions radiographique de rachis lombaire de ...

66

In vivo 3D geometrical modeling of the human trunk unsing EOS X-Ray system

In vivo 3D geometrical modeling of the human trunk unsing EOS X-Ray system

... DOSE EOS RESUME: L’utilisation de modèles en éléments finis du corps humain a été initiée au début des années 90 comme outil d’aide à la conception de dispositifs de sécurité ...

143

Le systeme EOS®, au-delà des limites de la pelvimétrie ? Une étude comparative et prospective monocentrique chez les femmes enceintes avec fœtus en présentation du siège

Le systeme EOS®, au-delà des limites de la pelvimétrie ? Une étude comparative et prospective monocentrique chez les femmes enceintes avec fœtus en présentation du siège

... the EOS® system induces higher maternal and foetal irradiation than that induced by an MRI examination, but it remains ...the EOS® system, the foetal dose was ...an EOS® pelvic examination was ...

75

Converted-wave seismic imaging: Amplitude-balancing source-independent imaging conditions

Converted-wave seismic imaging: Amplitude-balancing source-independent imaging conditions

... the imaging results: This model was produced from the difference between the original squared P-wave slowness (Figure 6a ) and a spatially smoothed squared P-wave slow- ness used in the imaging ...

12

Multi-Modality Diffuse Fluorescence Imaging Applied to Preclinical Imaging in Mice

Multi-Modality Diffuse Fluorescence Imaging Applied to Preclinical Imaging in Mice

... working in the angular domain might decrease scattering effect to detect deep objects in mice (Vasefi et al., 2009). Here, angular domain refers to a technique using the angular filter array ( AFA) to overcome to ...

186

Show all 1904 documents...

Sujets connexes