UP
UP
W/DW/DW/D W/D
W/D
W/
D
W/D W/D
W/
D
F W/D W/D
DN DN
W /D
W/D
DN
W/D
A
F E D C B
1
A203
B05 2BD-D
B12 1BD-H
B11 1BD-D
B10 STUDIO-C-B/F
B09 1BD-A
B08 1BD-E
B07 1BD-A0 B/F
B06 1BD-J
B04 1BD-A B03
STUDIO+BD-A B02
1BD-A B01
1BD-A B15
MECH/ELEC B14
1BD-I B13
1BD-K
1
A202
59 94
1
A200
1
A201
FHC
ELEC.
A STAIR
B STAIR
FHC
28 4
BEDROOM 97 SF
LIVING/ DINING/ KITCHEN 236 SF
BEDROOM 102 SF LIVING/DINING/KITCHEN
194 SF
LIVING/DINING/KITCHEN 195 SF
BEDROOM 97 SF
BEDROOM 102 SF
LIVING/DINING/KITCHEN 228 SF
BEDROOM 96 SF
LIVING/DINING/KITCHEN 222 SF
38 86 43 70 48 36 44 20 58 26
12 40
LIVING/DINING/KITCHEN 208 SF
LIVING/ DINING/ SLEEP 229 SF
LIVING/DINING/KITCHEN 194 SF LIVING/DINING/KITCHEN
200 SF
LIVING/ DINING/ KITCHEN 197 SF
BEDROOM 96 SF
BEDROOM 96 SF
BEDROOM 96 SF
BEDROOM 96 SF
LIVING/DINING/KITCHEN 198 SF BEDROOM
96 SF
BEDROOM 108 SF
LIVING/DINING/KITCHEN 230 SF
93 9
LIVING/ DINING/
KITCHEN/ SLEEPING 254 SF
BEDROOM 66 SF
PROPERTY LINE
WINDOW WELL
WINDOW WELL
WINDOW WELL WINDOW WELL
Collectif d'architectes
www.figurr.ca
Date de création du dessin / Drawing creation date Échelle / Scale Vérifié par / Verified by Titre / Title
No. dessin / Drawing number Sceau / Seal
Architecte / Architect
Droit d'auteur / Copyright
Ce dessin est sujet au droit d'auteur. Il ne peut être reproduit pour quelques intentions ou usages que ce soit, il ne peut être utilisé uniquement avec l'apposition de la signature et de l'estampe originale.
This drawing is subject to copyright. It is not to be reproduced for any purpose or by any means, and may only be used if it bears an original stamp and signature.
Projet / Project
Dessiné par / Drawn by No. projet / Project number Note:
L'entrepreneur doit vérifier toutes les dimensions et informations sur le site et aviser immédiatement l'architecte de toutes erreurs ou omissions.
Contractor shall verify all information and dimensions on site and immediately report any errors or omissions to the architect.
Révision / Revision Client / Client
Ingénieur / Engineer (Structure / Structure) Ingénieur / Engineer
(Mécanique & Électricité / Mechanical & Electrical)
fig. 1
3550, Saint-Antoine O.
Montréal QC H4C 1A9 T. 514 861-5122
fig. 2
190 Somerset St W #206 Ottawa ON K2P 0J4 T. 613 695-6122 Ingénieur / Engineer (Civil / Civil) Architecte / Architect (Payisagiste / Landscape)
1 : 100
3
SIX STOREY RESIDENTIAL BUILDING
1155 Joseph Cyr Ottawa, ON
BASEMENT PLAN
LK, JW
MD
06/05/18 A120
2034
1 2 1 2
B E N C H B E N C H B E N C H B E N C H
B E N C H B E N C H
UP
UP
UP
W/DW/D W/D
F W/D W/D
W/D W/D W/D
W/D
1
A
2 3 4 5 6 7 8 9
F E D C B
11
1
A203
105 1BD-A B/F
106 1BD-E 107
1BD-A 108
STUDIO-C-BF
109 1BD-D
COMM1 COMMERCIAL UNIT
1377 SF
101 1BD-A
102 1BD-A
103 STUDIO+BD-A
104 1BD-A
110 WATER/FIRE
10
PROPERTY LINE
DASHED LINE INDICATES EXTENT OF TYPICAL FLOORS ABOVE
3m OBC SE TBA CK
H Y D R O S E T B A C K ( 6m ) HYDRO SETBACK (6m)
F U T U R E R O A D W ID E N IN G
FUTURE ROAD WIDENING
1
A202
15 13 15 94
1473
31 8
1500 1500
111 Bicycle storage
653 SF 96 Bike racks
76 5
1500
10 00
1 6046
A200
1
A201
FHC
RESIDENTIAL LOBBY MAIL ROOM
ELEC.
FHC
GARBAGE/RECYLING
BEDROOM 96 SF LIVING/DINING/KITCHEN
224 SF
4858 4267 4267 4267 4420 4420 4420 4420 1652 6457
38 86 43 70 48 36 44 20 58 26
A STAIR
B STAIR WINDOW WELL
(TYP.)
WINDOW WELL (TYP.)
70260
1510
PROPERTY LINE
RESIDENTIAL EXIT
COMMERCIAL ENTRANCE
DASHED LINE INDICATES EXTENT OF CANOPY
OVERHANG ABOVE SLO PE UP
RESIDENTIAL EXIT
Collectif d'architectes
www.figurr.ca
Titre / Title Sceau / Seal Architecte / Architect
Droit d'auteur / Copyright
Ce dessin est sujet au droit d'auteur. Il ne peut être reproduit pour quelques intentions ou usages que ce soit, il ne peut être utilisé uniquement avec l'apposition de la signature et de l'estampe originale.
This drawing is subject to copyright. It is not to be reproduced for any purpose or by any means, and may only be used if it bears an original stamp and signature.
Projet / Project
Note:
L'entrepreneur doit vérifier toutes les dimensions et informations sur le site et aviser immédiatement l'architecte de toutes erreurs ou omissions.
Contractor shall verify all information and dimensions on site and immediately report any errors or omissions to the architect.
Client / Client Date
No. Émis pour / Object
Ingénieur / Engineer (Structure / Structure) Ingénieur / Engineer
(Mécanique & Électricité / Mechanical & Electrical)
fig. 1
3550, Saint-Antoine O.
Montréal QC H4C 1A9 T. 514 861-5122
fig. 2
190 Somerset St W #206 Ottawa ON K2P 0J4 T. 613 695-6122 Ingénieur / Engineer (Civil / Civil) Architecte / Architect (Payisagiste / Landscape)
SIX STOREY RESIDENTIAL BUILDING
1155 Joseph Cyr Ottawa, ON
FIRST FLOOR PLAN
1 2020-07-17 Client review 3 2020-10-01 SITE PLAN CONTROL
UP UP
W/DW/DW/DW/D
F
W/D
W/
D
F W/D W/D W/D
W/D
W/D
W /D
W/D W/D
W /D
W/D
W /D
W /D W/
D
A
F E D C B
1
A203
211 2BD-B
210 STUDIO-F
209 STUDIO-A
208 STUDIO-A2
207 1BD-L-B/F
206 1BD-K-B/F 205
1BD-A 204
1BD-A 203
1BD-A 202
1BD-A 201
STUDIO+BD-B 219
STUDIO-B 218
2BD-D B/F 217
1BD-F
216 1BD-D
215 STUDIO-C-BF
214 1BD-A
213 1BD-E
212 1BD-A0 B/F
1
A202
1
A200
1
A201
ELEC.
FHC
FHC
EXTENT OF CANOPY OVERHANG BELOW
EXTENT OF FIRST FLOOR BELOW
60 00
3m OBC SE TBA CK
H Y D R O S E T B A C K ( 6m ) HYDRO SETBACK (6m)
F U T U R E R O A D W ID E N IN G
FUTURE ROAD WIDENING
BEDROOM 103 SF LIVING/ DINING/
KITCHEN 225 SF
LIVING/ DINING/ KITCHEN 217 SF
BEDROOM 113 SF
BEDROOM 110 SF LIVING/ DINING/
KITCHEN 215 SF
BEDROOM 87 SF
LIVING/ DINING/
KITCHEN 240 SF BEDROOM
100SF
LIVING/ DINING/
KITCHEN 194 SF
LIVING/ DINING/
KITCHEN/ SLEEPING 214 SF
38 86 43 70 48 36 44 20 58 26
A STAIR
B STAIR
LIVING/DINING/KITCHEN 208 SF LIVING/DINING/KITCHEN
197 SF LIVING/DINING/KITCHEN
163 SF
BEDROOM 96 SF BEDROOM
96 SF BEDROOM
96 SF BEDROOM
108 SF
BEDROOM 96 SF LIVING/ DINING/
KITCHEN/SLEEPING 261 SF LIVING/ DINING/
KITCHEN/SLEEPING 231 SF LIVING/ DINING/
KITCHEN/SLEEPING 212 SF
PROPERTY LINE
Collectif d'architectes
www.figurr.ca
Date de création du dessin / Drawing creation date Échelle / Scale Vérifié par / Verified by Titre / Title
No. dessin / Drawing number Sceau / Seal
Architecte / Architect
Droit d'auteur / Copyright
Ce dessin est sujet au droit d'auteur. Il ne peut être reproduit pour quelques intentions ou usages que ce soit, il ne peut être utilisé uniquement avec l'apposition de la signature et de l'estampe originale.
This drawing is subject to copyright. It is not to be reproduced for any purpose or by any means, and may only be used if it bears an original stamp and signature.
Projet / Project
Dessiné par / Drawn by No. projet / Project number Note:
L'entrepreneur doit vérifier toutes les dimensions et informations sur le site et aviser immédiatement l'architecte de toutes erreurs ou omissions.
Contractor shall verify all information and dimensions on site and immediately report any errors or omissions to the architect.
Révision / Revision Client / Client
Ingénieur / Engineer (Structure / Structure) Ingénieur / Engineer
(Mécanique & Électricité / Mechanical & Electrical)
fig. 1
3550, Saint-Antoine O.
Montréal QC H4C 1A9 T. 514 861-5122
fig. 2
190 Somerset St W #206 Ottawa ON K2P 0J4 T. 613 695-6122 Ingénieur / Engineer (Civil / Civil) Architecte / Architect (Payisagiste / Landscape)
1 : 100
3
SIX STOREY RESIDENTIAL BUILDING
1155 Joseph Cyr Ottawa, ON
2ND-3RD FLOOR PLAN
LK, JW
MD
06/05/18 A122
2034
W/DW/DW/D
F
W/D
W/
D W/
D
F W/D W/D
W/D F W/D
W /D
W/
D
W/D
W/D W/D
W /D
W/D
W/
D
F
W/
D
1
A
2 3 4 5 6 7 8 9
F E D C B
11
1
A203
411 2BD-G
412 STUDIO-A4 413
STUDIO+BD
414 STUDIO-D 415
STUDIO-C-BF 416
1BD-D
417 1BD-F
418 2BD-D B/F
419 STUDIO-B
401
STUDIO+BD-B 402
1BD-A 403
1BD-A
404 1BD-A
405 1BD-A
406 2BD-A-BF
407 STUDIO-A
408 STUDIO-A2
409 STUDIO-A 410
STUDIO-F 10
1
A202
1
A200
1
A201
EXTENT OF BALCONY ABOVE
EXTENT OF BALCONY ABOVE
ELEC.
FHC
FHC
60 00
3m OBC SE TBA CK
H Y D R O S E T B A C K ( 6m ) HYDRO SETBACK (6m)
F U T U R E R O A D W ID E N IN G
FUTURE ROAD WIDENING
BALCONY
BALCONY EXTENT OF THIRD
FLOOR BELOW
BEDROOM 97 SF LIVING/ DINING/
KITCHEN 225 SF
LIVING/ DINING/ KITCHEN/
SLEEPING 262 SF
LIVING/ DINING/ KITCHEN/
SLEEPING 237 SF
4858 4267 4267 4267 4420 4420 4420 4420 1652 6457
38 86 43 70 48 36 44 20 58 26
A STAIR
B STAIR
LIVING/ DINING/ SLEEP 203 SF
LIVING/ DINING 161 SF
BEDROOM 96 SF
BEDROOM 90 SF
LIVING/DINING/
SLEEP 228 SF BALCONY
LIVING/DINING/
KITCHEN 226 SF BEDROOM
84 SF
BEDROOM 98 SF
PROPERTY LINE
Collectif d'architectes
www.figurr.ca
Titre / Title Sceau / Seal Architecte / Architect
Droit d'auteur / Copyright
Ce dessin est sujet au droit d'auteur. Il ne peut être reproduit pour quelques intentions ou usages que ce soit, il ne peut être utilisé uniquement avec l'apposition de la signature et de l'estampe originale.
This drawing is subject to copyright. It is not to be reproduced for any purpose or by any means, and may only be used if it bears an original stamp and signature.
Projet / Project
Note:
L'entrepreneur doit vérifier toutes les dimensions et informations sur le site et aviser immédiatement l'architecte de toutes erreurs ou omissions.
Contractor shall verify all information and dimensions on site and immediately report any errors or omissions to the architect.
Client / Client Date
No. Émis pour / Object
Ingénieur / Engineer (Structure / Structure) Ingénieur / Engineer
(Mécanique & Électricité / Mechanical & Electrical)
fig. 1
3550, Saint-Antoine O.
Montréal QC H4C 1A9 T. 514 861-5122
fig. 2
190 Somerset St W #206 Ottawa ON K2P 0J4 T. 613 695-6122 Ingénieur / Engineer (Civil / Civil) Architecte / Architect (Payisagiste / Landscape)
SIX STOREY RESIDENTIAL BUILDING
1155 Joseph Cyr Ottawa, ON
4TH-5TH FLOOR PLAN
1 2020-07-17 Client review 3 2020-10-01 SITE PLAN CONTROL
F W/
D
W/DW/DW/D
F
W/D
W/
D W/
D
F W/D W/D
F W/D
W/
D
W/D
W/D W/D
W /D
W/D
W/
D
A
F E D C B
1
A203
1
A202
1
A200
1
A201
FHC
ELEC.
FHC
A STAIR
B STAIR 616
1 BD-D
615 STUDIO-C-BF
614 STUDIO-D
613 STUDIO+BD
612 STUDIO-A4
611 2 BD-G
610 STUDIO F
609 STUDIO A
608 STUDIO A2
607 STUDIO A
606 2 BD-A-BF 605
1 BD-A 604
1 BD-A 603
1 BD-A 602
1 BD-A 601
STUDIO+BD-B 618
STUDIO B 617
AMENITY
BALCONY BALCONY
BALCONY BALCONY
BALCONY
PROPERTY LINE
3m OBC SE TBA CK
H Y D R O S E T B A C K ( 6m ) HYDRO SETBACK (6m)
F U T U R E R O A D W ID E N IN G
FUTURE ROAD WIDENING
38 86 43 70 48 36 44 20 58 26
Collectif d'architectes
www.figurr.ca
Date de création du dessin / Drawing creation date Échelle / Scale Vérifié par / Verified by Titre / Title
No. dessin / Drawing number Sceau / Seal
Architecte / Architect
Droit d'auteur / Copyright
Ce dessin est sujet au droit d'auteur. Il ne peut être reproduit pour quelques intentions ou usages que ce soit, il ne peut être utilisé uniquement avec l'apposition de la signature et de l'estampe originale.
This drawing is subject to copyright. It is not to be reproduced for any purpose or by any means, and may only be used if it bears an original stamp and signature.
Projet / Project
Dessiné par / Drawn by No. projet / Project number Note:
L'entrepreneur doit vérifier toutes les dimensions et informations sur le site et aviser immédiatement l'architecte de toutes erreurs ou omissions.
Contractor shall verify all information and dimensions on site and immediately report any errors or omissions to the architect.
Révision / Revision Client / Client
Ingénieur / Engineer (Structure / Structure) Ingénieur / Engineer
(Mécanique & Électricité / Mechanical & Electrical)
fig. 1
3550, Saint-Antoine O.
Montréal QC H4C 1A9 T. 514 861-5122
fig. 2
190 Somerset St W #206 Ottawa ON K2P 0J4 T. 613 695-6122 Ingénieur / Engineer (Civil / Civil) Architecte / Architect (Payisagiste / Landscape)
1 : 100
3
SIX STOREY RESIDENTIAL BUILDING
1155 Joseph Cyr Ottawa, ON
6TH FLOOR
LK, JW
MD
08/10/20 A124
2034
1
A
2 3 4 5 6 7 8 9
F E D C B
11
1
A203
10
1
A202
Roof Top Amenity = 5234 SF 1
A200
1
A201
FHC
9693 SF MECH.
3m OBC SE TBA CK
H Y D R O S E T B A C K ( 6m ) HYDRO SETBACK (6m)
F U T U R E R O A D W ID E N IN G
FUTURE ROAD WIDENING
4858 4267 4267 4267 4420 4420 4420 4420 1652 6457
38 86 43 70 48 36 44 20 58 26
A STAIR
B STAIR
PROPERTY LINE
Collectif d'architectes
www.figurr.ca
Titre / Title Sceau / Seal Architecte / Architect
Droit d'auteur / Copyright
Ce dessin est sujet au droit d'auteur. Il ne peut être reproduit pour quelques intentions ou usages que ce soit, il ne peut être utilisé uniquement avec l'apposition de la signature et de l'estampe originale.
This drawing is subject to copyright. It is not to be reproduced for any purpose or by any means, and may only be used if it bears an original stamp and signature.
Projet / Project
Note:
L'entrepreneur doit vérifier toutes les dimensions et informations sur le site et aviser immédiatement l'architecte de toutes erreurs ou omissions.
Contractor shall verify all information and dimensions on site and immediately report any errors or omissions to the architect.
Client / Client Date
No. Émis pour / Object
Ingénieur / Engineer (Structure / Structure) Ingénieur / Engineer
(Mécanique & Électricité / Mechanical & Electrical)
fig. 1
3550, Saint-Antoine O.
Montréal QC H4C 1A9 T. 514 861-5122
fig. 2
190 Somerset St W #206 Ottawa ON K2P 0J4 T. 613 695-6122 Ingénieur / Engineer (Civil / Civil) Architecte / Architect (Payisagiste / Landscape)
SIX STOREY RESIDENTIAL BUILDING
1155 Joseph Cyr Ottawa, ON
ROOF / PENTHOUSE PLAN
3 2020-10-01 SITE PLAN CONTROL