• Aucun résultat trouvé

Software Product Description

N/A
N/A
Protected

Academic year: 2022

Partager "Software Product Description "

Copied!
2
0
0

Texte intégral

(1)

~DmDDmD

Software Product Description

-

~,-,-

PRODUCT NAME:

Power Management/301,

Version 1 SPD 15.76.1

DESCRIPTION:

The Power Managementl301 ,applications software monitors electrical power usage and shuts off, or throttles back, selected equipment to reduce peak power requirements and reduce total energy con- sumption. Flexible operation is provided by a large base of user-specified parameters.

English-like operator commands are used on the op- erator terminal for dialogue with the system. Meter and load status reports are available on request or on a scheduled basis. Historical data can be recorded on cassette for later play-back.

The system determines power usage levels through connections to the pwer metering equipment. Based on actual usage levels, power levels are forecasted and compared with a desired target level. Up to 96 load control outputs are shut off depending on the difference between target and forecasted demand values. Equipment is shut down according to user- specified priorities and will be turned on again after a specified off-time. Up to 6 different off-times can be specifed during the 24 hour day. Equipment will not be shut down again before a cycle time has passed In order to prevent excessive on/off cycling.

If the system forecasts that the pre-specified target demand value will be exceeded despite the maximum effort of the system to shed all available loads, a warning message will alert the operator to permit manual control of loads.

Once the system operating parameters have been en- tered or altered, a command can save the parameters on cassette. Several sets of parameters can be set up and saved. Later. the parameters can be reloaded into the system for quicker system start-up without re-enterlng the parameters.

A simulation mode provides a software Simulated power meter. Repeatable power peaks are generated by the power meter and supplied to the system con- trol programs. Parameters such as off-times and cy- cle-times can be "tried-out" in simulation mode. Re- ports can be printed or data recorded Just as with actual power meter connections.

September 1977

MINIMUM HARDWARE REQUIRED:

Any PDP-1~.·10, 11/40, 11/45 processor with 16K words of memory. KW11-L clock (with PDP-11/40), and BM873-YZ ROM bootstrap.

• T A 11 cassette

• LA36, LT33 or LT35 console terminal.

• ICS-11 industrial subsystem and 110 modules.

OPTIONAL HARDWARE:·

• Additional memory to a system total of 24K words.

• Additional ICS-11 I/O modules.

PREREQUISITE SOFTWARE:

None

OPTIONAL SOFTWARE:

None

TRAINING CREDITS:

None

SUPPORT CATEGORY:

C - Software Support will be provided as listed In the Software Support Categories Addendum to this SPD.

UPDATE POLlC¥:

No updates are planned for this product.

ORDERING INFORMA"rlON:

This software is furnished under a license for use on a single CPU and can be copied and modified (with Inclusion of DIGITAL's copyright notice) only for use on such CPU, except as may otherwise be provided in writing by DIGITAL.

Source and/or listing options are only available after the purchase of at least one supported license and after a source license agreement Is tn effect.

The following kfJY (N, R. Z) represents the distribution media for the product and must be specified at the end of the "0" number, I.e .• OJ635-CN

=

binaries on cassette.

AE-3437B-TC

(2)

Power Management/301, Version 1

N = Cassette R

=

Microfiche

Z No hardware dependency Standard Options

QJ635 -C- Single-use license, binaries, documen- tation, no support services (media: N) Source/Listing Options

QJ635 -E- All sources (media: N) QJ635 -F- Listings (media: R) ADDITIONAL SERVICES:

None

015.76.1

SPD 15.76.1 -2-

Références

Documents relatifs

During the ninety (90) day period after installation, if the customer encounters a problem with the current unaltered release of the SOFTWARE which DIGITAL

During the ninety (90) day period after installation, if the customer encounters a problem with the current unaltered release of the SOFTWARE which DIGITAL

It uses memory management hardware to isolate all other areas of memory from a currently running program and to al- low a program to be loaded anywhere in

Upon notification by customer to the nearest DIGITAL office that the computer system, including all required prerequisite hardware and software, is ready for the

Како што може да се забележи од самата слика, применливоста на мо- делот е презентирана преку приказ на промената на шест големини и тоа: брзи- ната на

License: PATHWORKS V5.0 for DIGITAL UNIX (LAN Manager) PC Concurrent License When you purchase the above license you may use the following program (‘‘Software’’) under the terms

In configurations where the DECnet Router Server is used to couple a small network section, or a series of endnodes, to the Ethernet, then it is expected that the actual packet

DIGITAL DOES NOT WARRANT THAT THE SOFTWARE LICENSED TO CUSTOMER SHALL BE ERROR FREE, THAT THE SOFTWARE SHALL OPERATE WITH ANY HARDWARE AND SOFTWARE OTHER THAN AS SPECIFIED