• Aucun résultat trouvé

Direct-Injection Mass Spectrometry (DIMS) for the analysis of aroma compounds

N/A
N/A
Protected

Academic year: 2021

Partager "Direct-Injection Mass Spectrometry (DIMS) for the analysis of aroma compounds"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-02785859

https://hal.inrae.fr/hal-02785859

Submitted on 4 Jun 2020

HAL is a multi-disciplinary open access archive for the deposit and dissemination of sci- entific research documents, whether they are pub- lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Distributed under a Creative Commons CC0 - Public Domain Dedication| 4.0 International License

Direct-Injection Mass Spectrometry (DIMS) for the analysis of aroma compounds

Jean-Luc Le Quéré

To cite this version:

Jean-Luc Le Quéré. Direct-Injection Mass Spectrometry (DIMS) for the analysis of aroma compounds.

Journées françaises de Spectrométrie de Masse et Analyse Protéomique (SMAP 2019), Sep 2019, Strasbourg, France. 1 p. �hal-02785859�

(2)

Abstracts should be submitted in english

Direct-Injection Mass Spectrometry (DIMS) for the analysis of aroma compounds

Direct-injection mass spectrometry (DIMS) techniques have evolved into powerful methods to analyse volatile organic compounds (VOCs) without the need of chromatographic separation. In food-related applications, they have been used as on-line techniques for monitoring processes, quantification of VOCs, aroma release studies, profiling and fingerprinting foodstuffs. Combined to chemometrics, they have been used to solve sample categorization issues based on volatilome determination. They have also been used for real-time in-vivo aroma release experiments, in a method known as breath-by-breath analysis or the

“nosespace” technique [1].

Starting with the notion of MS-based electronic nose, this presentation will be essentially devoted to on- line chemical ionization MS (CI-MS) methods: atmospheric pressure chemical ionization MS (APCI-MS), selected ion flow tube MS (SIFT-MS), and proton transfer reaction MS (PTR-MS).

For years, APCI-MS has been the reference technique for in-vitro and in-vivo monitoring of flavour compounds. Some examples of the early work [1, 2] and from our own developments [3] will be presented.

SIFT-MS has been used extensively to study the chemistry of ion-molecule reactions, and determining k- rate coefficients. SIFT-MS has also found practical analytical use in breath analyses and determination of biomarkers [4]. Recent improvement of the sensitivity in reduced size instruments has allowed worth mentioning studies relating aroma analyses.

A special attention will be paid to PTR-MS, and particularly to the powerful PTR-time of flight-MS (PTR-ToF- MS) instrument. Recent results obtained by our group will be presented for in-vitro (profiling dark chocolates with different organoleptic properties [5]), ex-vivo (real-time monitoring of volatile metabolites resulting from nasal odorant metabolism), and in-vivo (nosespace analyses and real-time monitoring of nasal metabolism) applications.

References

[1] A. J. Taylor, R. S. T. Linforth, B. A. Harvey and A. Blake. Atmospheric pressure chemical ionisation mass spectrometry for in vivo analysis of volatile flavour release. Food Chem., 71, 327-338, (2000).

[2] A. J. Taylor and R. S. T. Linforth. Direct mass spectrometry of complex volatile and non-volatile flavour mixtures. Int. J. Mass Spectrom., 223-224, 179-191, (2003).

[3] J. L. Le Quéré, I. Gierczynski and E. Sémon. An atmospheric pressure chemical ionization - ion-trap mass spectrometer for the on-line analysis of volatile compounds in foods: a tool for linking aroma release to aroma perception. J. Mass Spectrom., 49(9), 918-928, (2014).

[4] P. Španěl and D. Smith. Progress in SIFT-MS: Breath analysis and other applications. Mass Spectrom.

Rev., 30(2), 236-267, (2011).

[5] Z. Deuscher, I. Andriot, E. Sémon, M. Repoux, S. Preys, J.-M. Roger, R. Boulanger, H. Labouré and J.-L. Le Quéré. Volatile compounds profiling by using Proton Transfer Reaction – Time of Flight – Mass Spectrometry (PTR-ToF-MS). The case study of dark chocolates organoleptic differences. J. Mass Spectrom., 54(1), 92-119, (2019).

Keywords

Direct-injection mass spectrometry; on-line chemical ionization mass spectrometry; aroma

Références

Documents relatifs

The aim of using deconvolution in SIMS profiles is to retrieve the shape and to improve depth resolution broad- ened by the analysis. A more appropriate and flexible method is

christi. Une autre qualité est systématiquement mentionnée, la beauté de visage et de corps : dans un univers symbolique où la laideur est forcément le signe

Two hypotheses might explain this: (1) spatio and/or tem- poral changes of tension wood quality (variations of a) during the gravitropic response are large and become more

Parallèlement à ces approches théoriques, de multiples études pratiques étaient réalisées au niveau des pays, des branches ou des industries( 2 ). Ces différents travaux ont

WAVELET ENCODING GRADIENT ECHO IMAGING SEQUENCE USING REAL TIME DE-NOISING METHOD FOR ACQUISITION TIME REDUCTION..

This research emphasised two levels property classes are operating at: at the level of transformation languages, the property classes correspond to those of any computa-

Dans les autres cas, des oligonucléotides de synthèse portant des motifs CpG (CpG-ODN) peuvent être utilisés de façon locale pour stimuler l’immunité innée et favoriser

All kinds of ions can be trapped simultaneously and since parametric resonances are proportional to the square root of the charge/mass ratio the EIBT can be used as a mass