Distributed Systems Network
Advanced Terminal Processor (DSN/ATP)
Offline Diagnostic Manual
..
F'i;' HEWLETT
~e.. PACKARD
DISTRIBUTED SYSTEMS NETWORK
Advanced Terminal Processor (DSN/ATP)
Offline Diagnostic Manual
FliDW HEWLETT a:aI PACKARD
INFORMATION NETWORKS DIVISION
19420 HOMESTEAD ROAD, CUPERTINO, CALIFORNIA 95014
NOTICE
The information contained in this document is subject to change without notice.
HEWLETI-PACKARD MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATER- IAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, perfor- mance or use of this material.
Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard.
This document contains proprietary information which is protected by copyright. All rights are reserved.
No part of this document may be photocopied, reproduced or translated to another program language without the prior written consent of Hewlett-Packard Company. .
Copyright
©
1982 by HEWLETT-PACKARD COMPANYii
LIST OF EFFECTIVE PAGES I
The List of Effective Pages gives the most recent date on which technical material on any given page was altered.
Ifa page is simply re-arranged due to a technical change on a previous page, it
isnot listed as a changed page. Within the manual, changes are marked with a vertical bar in the margin.
First Edition ••.. . • • . • • • . . • • • . • . . . • March 1982
I PRINTING HISTORY
New editions incorporate all update material since the previous edition. Update packages, which are issued between editions, contain additional and replacement pages to
bemerged into the manual by the customer. The date on the title page and back cover changes only when a new edition
ispublished.
Ifminor corrections and updates are in- corporated, the manual is reprinted but neither the date on the title page and back cover nor the edition changes.
First Edition . . . • . . . . • . . . . • . • . • • • • • March 1982
iv
PREFACE I
This manual describes the Offline Diagnostics for the Advanced Terminal Processor (ATP). The ATP is an asynchronous device controller for HP 3000/44 and HP 3000/64 computer systems. The ATP interfaces with the Intermodule Bus (1MB) for I/O data transfer. A minimum ATP subsystem consists of one System Interface Board, (SIB), and one Hardwired Port Controller or one Modem Port Controller. It requires 2 I/O slots, uses one 1MB channel address and supports 12 ports. The maximum subsystem consists of one System Interface Board, and eight Port Controllers. It requires nine slots, uses one 1MB channel address and can support 96 terminal ports.
AnHP 3000/64 computer may have a maximum of 2 ATP subsystems installed, which support 144 terminals. Each ATP subsystem requires one unique 1MB channel address.
This manual is written for the HP Customer Engineer (CE) with the assumption that the reader has a good working knowledge of the lIP 3000 system environment, and is specifically trained on trouble- shooting HP 3000 products. This manual provides information and instructions for setting up the ATP subsystem, and for diagnostic testing. This manual may be used in conjunction with related documentation for the HP 3000 Series 44/64 Computer Systems.
Related documents include the following technical manuals:
• HP 3000 Computer Systems, Console Operator's Guide, (for series 11/111/30/33/40/44/64) part number 32002-90004.
• part number 30000-90105 HP 3000 Computer Systems,
Communication Handbook,
• HP 3000 Computer Systems, Systems Manager/System Supervisor Reference Manual, part number 30000-90014
• HP 3000 Distributed Systems Network/Advanced Terminal Processor Installation Manual, part number 30144-90002
• HP 3000 Distributed Systems Network/Advanced Terminal Processor On-Line Diagnostic Manual, part number 30144-90004
• HP 3000 Asynchronous part number 30000-90250
Serial I/O Reference Manual,
I PREfACE (Continued)
This manual is organized as follows:
Section I, General Information, briefly describes the main areas of importance in terms of diagnostic needs. It includes descriptions of the required software and hardware. It also discusses testing philosophy and limitations of the Advanced Terminal Processor diagnostics.
Section II, pertaining diagnostics.
organization.
Operating Instructions, to the proper operating
It explains the commands,
contains information procedures for the prompts and program
Section III, Execution Times, contains information pertaining to approximate run times of the diagnostic tests.
Section IV, Test Descriptions, Connector test applications.
dialog are given.
covers the SIB, AlB and Port Test explanations and a sample
Section V, Error Interpretation, supplies information for test result analysis. It also supplies sample error messages.
Appendix A, Troubleshooting Flow Chart, supplies information on troubleshooting the subsystem through the use of the diagnostics.
Appendix a, Loopback Hoods, contains pictures of the Loopback Hoods needed for running the Loopback Tests.
Appendix C, Wiring Diagrams, contains pictures for cable wiring.
vi
TABLE OF CONTENTS
.. .. ... . .. . . .. ..
. .. . . . . . ... . ... .
1-1 1-1 1-4 1-4 1-5
. ...
. .. .
. . .
. ... . . . . .
. . . . . . .. . .. . .
. . . . ..
...
...
.. . . . . .
1
INFORMATION Introduction ••.•••
Required Hardware.
Required Software.
Testing Philosophy ••
Diagnostic Limitations.
Section GENERAL
Messages and Prompts ••
Sample Dialog ••••.••••
Section II
OPERATING INSTRUCTIONS
Introduction ••••••••• ... .. . ...
. . .. . . .. .. .
. . . . . . ... . .. . . . ... . . . 2-1 2-1
2-2
Section III
EXECUTION TIMES • . . . . .. .. . . . . . . . . .. . .. .. . . . . . ... ... .. . ... .. . . . 3-1
·...
· .. . .. .. .. . . . . . . .
· .. .
· . .. .. . . . .
4-1 4-1 4-2 4-2 4-2 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-4 4-4 4-4 4-4 4-4 4-5 4-6 4-6 4-6
. ...
. .. . . . .. .
...
.. .. .... .. .
...
· ...
·. .. . . . .. . ..
· . ... . ...
· .. .. .
· . . . . . .
·...
·. .. . . . . .
· .. .. . .. . .
· .. . . . .
· . ....
·. . ...
·.. . . . .
. . . . . .. ... .. .
·. ·.
· ....
·.
· . . .
. .
.. . . .
1MB-SIB Communication.
Initial Register Values ••
Memory •••.••••••••
Sequencing •••••••••••••••
Time Out ••••••••••••••
Board Counter/Enable.
ATP Bus Buffers.
Direct Conunand ••
FIFO •••••••••••
DMA State Counter •••••
DMA Address Counter.
Comp/Counter Loopback ••
Read IMB •••••••••••••••••
Write 1MB •••••••••••••••
Begin Flag/Left-Right Flag.
Asynchronous Interface Board Tests Port Controller Chip Self-Test •••
Modem Controller Chip Self-Test.
Modem Scanner Chip Self-Test ••
Port Controller Chip Dump •••
ATP Offline Diagnostic Tests •••••
Offline Diagnostic Organization.
SIB Tests .•••••••••••••••••
Section IV
TEST DESCRIPTIONS
I TABLE OF CONTENTS (Continued)
Modem Scanner Chip Dump •••••••••••••••••••••••••• 4-6 PCC-MCC Communication •••••••••••••••••••••••••••• 4-6 Diagnostic Loopback •••••••••••••••••••
~•••••••••• 4-7 Off Board Loopback •••••••••••••••••••••••••••.•• 4-7 Section V
ERROR INTERPRETATION... 5-1 APPENDIX A
TROUBLESHOOTING FLOW CHART ••••••••••••••••••••••••••••••••••• A-I INDEX •..••••••••••.•••· ••••••••••••••••••••••••••••••••••••••• I-I
I ILLUSTRATIONS
FIGURE TITLE PAGE
1-1 Series 44 Asynchronous Subsystem ••••••••••••••••• 1-2 1-2 Series 64 Asynchronous Subsystem •••••••••••••••••• 1-3 4-1 Location of Power Switch on AlB ••••••••••••••••••• 4-8 B-2 AlB Loopback Hood... B-1 B-1 HP-Modern B Loopback Hood •••••••••••••••••••••••••• B-2 B-3 HP DC A and HP DC B Loopback Hood ••••••••••••••••• B-3 C-l Wiring Diagram for HP DC B Adapter Cable •••••••••• C-l C-2 Cable Wiring for HP DC A and HP DC B Hoods •••••••• C-2
viii
GENERAL INFORMATION I~
INTRODUCTION
This diagnostic test program confirms correct operation of the System Interface Board, Asynchronous Interface Board, Port Connector Assembly and associated cabling. The Port Connector assembly consists of a Mother Board, either modem or direct connect, three or six Mini-Boards, and one cable. It operates on HP 3000 Series Series 44 and Series 64 systems. Communication with the operator is via the system console.
Hereafter, in this document, the following acronyms will be used:
System Interface Board •••••••••••• SIB Asynchronous Interface Board •••••• AIB Advanced Terminal Processor ••••••• ATP
Board replacement is the standard operating procedure and the diagnostics are designed to easily identify malfunctioning boards within the ATP system. The diagnostics allow you to run specific individual tests or all the tests as a group. After all the tests have been run on a particular board, a pass/fail indication will be displayed to indicate which SIB/AlB has passed or failed.
We recommend you run the diagnostics by issuing the "ALL" command rather than specifying particular individual tests •.
REQUIRED HARDWARE
The following hardware is required:
a. A minimal mainframe configuration.
b. A minimal ATP system, ie: one SIB, one Port Controller, which consists of one AlB and one Port Connector Assembly, either Modem or Direct Connect.
c. Loopback Hoods which are included in the product support package (p/n 30144-67801).
One Standard 72 Pin Edge Connector
Twelve 25 Pin Hoods for HP-Modem B Connection Twelve 3 Pin Hoods for HP-DC B Connection Twelve 5 Pin Hoods for HP-DC A Connection
30145-60005
30146-60002
30148-60002
30147-60002
General Information
If necessary, the SIB can be tested without an AlB being present.
Also, the AlB can be tested without Port Connectors being pre- sent. However, the most thorough testing is done with all ATP hardware installed.
SERIES 44 ASYNCHRONOUS SUBSYSTEM
•
•
•
1
4DEVICES ORMODEMSRS-232-CGIC
SYSTEM INTERFACE BOARD (SIBI
ASYNCHRONOUS INTERFACE BOARD
(AIBIO
•
•
•
•
MEM ARRAY
#1 MEM ARRAY
#()
MEM ARRAY
#1 MEMORY CONTROLLER CPU
r - -...
-~~--1
BIC
I 1
... ~_~I 1...--.-.
...- -... , 1
I I ....----..
CONTROLLER...._ _. . . . 7
L ,
ADCC
1
4 RS-232-eI
MAIN DEVICES ORMODEMS
I
I I
t-- - - ... I
HP DCA HPDCB
(AIBI7
L...
J
Figure 1-1. Series 44 Asynchronous SUbsystem
1-2
General Information
SERIES 64 ASYNCHRONOUS SUBSYSTEM
I I I
I I I I
HP DCA
I
HP DC B
I
HPMODEM B 2
•
•
GIC
GIC
UP TO 10
•
L - - - -
iiien
1
g IMBI
en SYSTEM INTER-
:::l FACE BOARD
CD
::E lOB (SIB) 1
I-w 2
>en
en ASYNCHRONOUS
.J« CBI INTERFACE BOARD
~ 2
I- (AIB)O
zw
(J
CD
~
r- ..,
IMBII I
lOBI
1I
CBII
1 CDI !
I I I I I
L ,
I
I I
I I I
""8)7I
L...,
I
~ . -~- ---~CBI 5
CBI 7 CAC
CMA
MCS MMC CPU
MMA 0
fI)
:::l CD
>~ MMA
0 1
~w ::E
•
•
•
•
MMA 7
Figure 1-2. Series 64 Asynchronous Subsystem
General Information
REQUIRED SOFTWARE
The Diagnostic Utility operating System (DUS) tape or diskette, and the ATP Offline Diagnostics are required.
TESTING PHILOSOPHY
The offline diagnostics are designed to test the ATP hardware and a subset of the code resident in the Port Controller Chips (PCC), Modem Controller Chips (MCC), and Modem Scanner Chips (MSC), if applicable. Only a subset of the code can be tested because i t is impossible to emulate all of the actions of terminals and/or modems simply by using loopback mechanisms. The SIB must be functioning correctly in order for the other components of the ATP to be tested. The recommended procedure is to initiate the diagnostics by thoroughly exercising the SIB to ensure that i t is operating correctly. To initiate the SIB tests, respond with the
"ALL" reply when prompted by the diagnostic. If the console goes through the SIB under test, the results must be directed to a line printer. Ensure that the line printer is on-line before you test the SIB. If the diagnostics find that the SIB is properly operating, testing of the AlB commences. It is recommended that the "ALL NO LOOPBACK
Ittests be run first. If these tests fail, the AlB must be replaced. If they pass, the loopback test should be performed with loopback hoods on the Port Connectors. If these loopback tests fail, loopback tests should be performed with loopback hoods on the AlB. By performing the tests in this sequence and through the use of mUltiple loopback hoods, each port on AlB is tested individually to ensure that the logic associated with it is operating. Thus all the ports on the AlB under test are analyzed.
1-4
General Information
DIAGNOSTIC LIMITATIONS
The diagnostic test limitations of the ATP are the following:
1) When the console is connected to the SIB under test, the messages must be output to a line printer. Make sure that the line printer being used is on line, when the DUS is brought up.
2) In order to be able to initiate the ATP offline diagnostics, the console port must be working. Therefore the console microdiagnostics supplied with the SPU microdiagnostics must be relied upon for diagnosing the console if there are any problems with it.
3) Sometimes i t will be difficult to isolate the problem
area to either the SIB or the AlB unless there are known good
SIBs and/or AIBs with which to test.
OPERATING INSTRUCTIONS I~
INTRODUCTION
The ATP diagnostics are designed to be operated easily. The tests can be run individually if so specified or as a group. We recommend that you do not specify individual tests since by running the tests as a group you will receive the same results in a much faster time.
To operate the diagnostics, the following steps must be executed:
(1) Load the Diagnostic/Utility System (DUS) Tape or Diskette (2) Bring up the Diagnostic/Utility System (DUS)
"Enter Program Name" is displayed.
(3) Respond 'ATPDIAG ' to initiate the Diagnostic.
The ATP Diagnostic Program displays its title message and prompts for the Channel # of the SIB.
Respond accordingly to the questions presented.
MESSAGES AND PROMPTS
Four types of messages are output by the diagnostic:
help, information and error messages.
prompt,
Prompt messages (e.g., which channel number to test, etc.) require you to input the requested information.
Help messages are displayed whenever the HELP command is given, and provide a more complete description of what is needed.
Information messages (e.g., pass/fail) are displayed with no program pause.
Error messages are used to tell you when the ATP responded
unexpectedly to a given stimulus. Error messages are normally
inhibited. These are of the most use when doing actual debugging
and repair of the individual boards.
Operating Instructions
Before the diagnostics are started you can specify whether tHe diagnostics should stop after the first error or whether they should continue to test as much of the system as possible. You can also specify whether success messages or failure messages should be printed- We recommend you respond with a NO to the questions concerning errors and messages, since the results will be summarized at the end of the diagnostic testing-
SAMPLE DIALOG
Advanced Terminal Processor Offline Diagnostic V-OO.20
Enter HELP in response to any question for an explanation of what is required.
Enter EXIT in response to any question to terminate the program.
*Channel number of 1MB interface SIB is attached (0-3) 0*
*SERIES 64 ONLY*
Enter the channel number of the SIB under test: 1 Print failure messages? NO
Print success messages? NO
Output results to line printer? YES Stop on errors? NO
Loop count-(zero for continuous looping): 1 Enter SIB tests to be run:
>ALL
Enter AlB tests to be run:
>ALL NO LOOPBACK
Enter ports to be tested, separated by commas:
>AO
2-2
EXECUTION TIMES I~
INTRODUCTION
The exact execution time for each test or for a group of tests is determined by the following constraints:
• the number
o~ports under test
• the computer system on which the test is being conducted (Series 44, 64)
• the selection of test sections to be executed
BOARD SIB AlB
EXAMPLE:
TEST ALL
ALL NO LOOPBACK
APPROXIMATE RUN TIME
<10 seconds
<2 minutes
The total run time per pass on a fully loaded Series 64 with eight AIBs and 96 ports with no errors is:
SIn AlB
ALL
ALL NO LOOPBACK
2 seconds 36 seconds
The execution times listed above are based on the fastest time:
slower machines, of course, will result in slower pass times.
DESCRIPTION OF TESTS I~
ATP OFFLINE DIAGNOSTIC TESTS
Following is an explanation of the ATP Offline Diagnostic tests. You must specify which SIB to test to the diagnostics.
The diagnostics ask for the channel address of the SIB and the ports which are to be tested. Listed below are all of the sub- tests involved in the diagnostics. The diagnostics run through all of the sub-tests in sequence.
OFFLINE DIAGNOSTIC ORGANIZATION
The SIB is considered to be the foundation of the ATP system. All of its modules must be operational in order to be able to communicate with any ports. Therefore, the SIB modules are tested first. These modules are:
1) Logic for responding to 1MB commands, 2) registers,
3) memory,
4) DMA State Machine, and 5) ATP Bus State Machine.
Each port succession.
tests:
on the AlB is tested The test on each port
individually, in involves the following 1) PCC self-test,
2) PCC RAM dump,
3) PCC/MCC Communication, 4) PCC diagnostic loopback,
5) PCC loopback of data signals offboard--requiring loopback hood.
6) MCC/MSC self-test which sends results back to the mainframe, and
7) MCC/MSC RAM Dump.
Description of Tests
SIB Tests
Following is a list of test names that can be performed on the SIB:
(1) (2) (3)
(4)
(5) (6)
(7)
(8) (9) ( 10) (11 ) ( 12) (13) (14) (15) (16)
( 17)
1MB-SIB Communication Initial Register Values SIB Memory
Sequencing Time Out
Board Counter/Enable ATP Bus Buffers
Direct Command FIFO
DMA State Counter DMA Address Counter Comp/Counter Loopback Read 1MB
Write 1MB
Begin Flag/Left-Right Flag None
All
(1M) (IN) (M) (SE) (T) (BO) (L)
(01)
(F) (ST) (OM) (C) (R) (w) (BE) (N) (A)
The test names may be abbreviated as indicated. You may enter a list of tests, separated by semi-colons. ALL indicates that all available SIB tests are to be run. NONE indicates that testing of the SIB will not be done. Pressing carriage return in response to this question will cause the last SIB tests specified
(if any) to be retained.
NOTE: ALL is the recommended response.
TEST DESCRIPTION
1MB-SIB
COMMUNICATION
INITIAL REGISTER VALUES
~~is
procedure does preliminary testing of the SIB determining that all the allowable
1MB commands can be executed.
This procedure tests the values obtained from the readable registers after
initialization.
4-2
SIB MEMORY
SEQUENCING
Description of Tests
This procedure tests the memory on the SIB.
This memory is used to store the 1MB memory offset, pack byte and flags associated with each of the 128 DMA paths. It is tested by writing/reading a checkerboard pattern and writing/reading the address of each location.
The checkerboard test is done with the MDiag bit of the diagnostic control register both on and off. This tests all of the pack byte, as well as the flags.
This procedure tests the sequencing of the ATP bus state machine. It sets up a given set of conditions (e.g. no direct command, bus opcode=idle, board enabled) and then checks the ATP bus as i t single stepped through the logic.
TIMEOUT This routine
terminates the the ATP bus, or machine.
tests wait Halt
the timeout which for either BusEnd from from the DMA state
BOARD
COUNTER/ENABLE
ATP BUS BUFFERS
DIRECT COMMAND
FIFO
DMA STATE COUNTER
This procedure tests the operation of the board counter on the SIB. It checks that the counter is incremented each time the ATP bus state machine passes through state zero. The counter must be checked by disabling all but one board, and checking when the state ma- chine sees the current-board-enabled signal.
This procedure tests the ATP Bus buffers.
It first uses DMA test code to write data to the ATP bus and reads the looped back data.
It then makes sure that the value of the port pointer looped back matches the value written into the port pointer register.
This procedure tests the data paths which get a direct command to the ATP Bus.
This procedure tests the operation of the FIFO which stores the number of each port wishing to generate an interrupt.
This procedure checks the function of the DMA
state counter. It sets up an opcode which
points to diagnostic DMA code containing all
NOPS. This test simply checks that the coun-
ter increments each time until i t gets to the
halt command, and then resets to zero.
Description of Tests
DNA ADDRESS COUNTER
COMP/COUNTER LOOPBACK
READ 1MB
WRITE 1MB
BEGIN FLAG/
LEFT-RIGHT FLAG
This procedure uses test 1 of the diagnostic DMA code to check the operation of the DMA address counter. After an channel initialization, the counter value should be preset to IFFFF. On the next increment i t should overflow and go to zero. It will then count up from zero. Each value of the counter will be stored in memory.
This procedure tests the DMA logic's COMP register and address counter. It loads the DMA registers from memory, and then runs the test which dumps the registers back to memory.
This procedure tests an 1MB read operation using the diagnostic DMA routine which reads a single word from the 1MB and puts i t in the SIB RAM.
This procedure tests an 1MB write operation using the diagnostic DMA routine which writes a single word from the SIB RAM and puts i t in 1MB memory.
This procedure tests the operation of the BeginFlag and LeftRightFlag on the. SIB. The basic tool used in this test is the diag- nostic DMA operation which increments the counter a different number of times for each state of BeginFlag and LeftRightFlag, then stores the count in memory. First each of the four possible states are written to SIB memory register 1 and the test is used to check that the DMA logic sees the correct value of the flags. Then the BeginFlag, LeftRightFlag are both set to 1 and the test is used to check the automatic updating of the flags.
4-4
Description of Tests
Port Controller Tests
Nine diagnostic tests are performed on the AlB and
Port Connector Assembly. The test names are listed below:
AlB (1)
(2) (3) (4) (5) (6)
(7)
(8) (9) ( 10)
Port Controller Chip Self-Test
t~dem
Controller Chip Self-Test Port Controller Chip Dump
Modem Controller Chip Dump PCC-MCC Communication
Diagnostic Loopback Off-board Loopback ALL
All no Loopback None
(PCC S) (MCC D) (PCC D) (MCC D) (PCC M) (D) (L) (A) (ALL N) (N)
MODEM PORT CONNECTOR ASSEMBLIES (11) Modem Scanner Chip Self Test (12) Modem Scanner Chip Dump
The test names may be abbreviated as indicated. You may enter a list of tests separated by semi-c'olons. ALL indicates that all available AlB tests are to be run. ALL NO LOOPBACK indicates all AlB tests, except those which require a loopback hood, are to be run. NONE indicates that testing of the AlB is not to be done.
Pressing carriage return in response to the prompt will cause the last AlB tests specified (if any) to be retained.
NOTE: ALL NO LOOPBACK is the recommended response when using the diagnostics. If loopback connectors have been installed, ALL is recommended.
Excluding the Modem Scanner Chip self-test and the Modem Scanner Chip dump, which cannot be separated from their MCC counterparts, each test is run individually, and the diagnostics are designed to run the tests sequentially in an order which exercises all the necessary components.
Before you begin the diagnostic tests, the AlB can be tested by initiating the on-board diagnostic as explained below. The offline diagnostic can then begin with the testing of the SIB. After it has been determined that the SIB is
functioning properly, diagnostic tests on the AlB may begin.
a. Flip the tiny toggle momentary switch on the edge of the
AlB PCA to manually reset the AlB so that the self-test
can be initiated,. To initiate the self-test, use a
screwdriver or a similar tool to short out Test Point 5
and Test Point 7, which are between the Junction Panel
Description of Tests
b. Watch the 13 self-test light-emitting-diode (LED) indicators as the self-test program goes through its cycle. Upon completion of the self-test (approximately one second in duration), the LEOs will stop blinking. If no LEOs are lit, the AlB is working properly. If any LEOs are still lit, the AlB is malfunctioning.
The steps above test 90% of the logic on the chips on the AlB board. Once you have confirmed that the AlB chips are functioning, you can begin the AlB diagnostic tests. The diagnostics are able to pinpoint which board is malfunctioning and needs to be replaced. The response for each test is pass or fail. Since board replacement is the standard operating procedure, pass/fail is the only information needed from the diagnostic tests.
A quick way to check if the Modem Scanner Chip is properly functioning on the Modern Mother Board is to attach loopback _hoods on the mini-boards and flip the momentary toggle switch on the rear of the mother board. If the LED remains lit, the mother board is malfunctioning and should be replaced. This test checks the modem logic on the mother board and therefore should not be used when the diagnostics are running.
TEST DESCRIPTION
This procedure verifies the operational SELF TESTS (3) status of thePCC. The maskable inter- rupt path to the PCC/MCC/MSC and the PORT CONTROLLER CHIP data and control paths from the PCC the to the mainframe are tested.
MODEM CONTROLLER CHIP The tests exercise all the PCC's and and return the results to the mainframe.
MODEM SCANNER CHIP The self-tests includes a ROM check-sum, a RAM diagnostic and a timer test.
DUMP TESTS (3) PORT CONTROLLER CHIP MODEM CONTROLLER CHIP HODEl1 SCANNER CHI P
PCC-HCC
COHMUNICATION
This procedure freezes the PCC, issues a dump command and dumps the contents of RAM and Control Registers to mainframe memory. The non-maskable interrupt path to the PCC, the maskable interrupt path and the' freeze code in the PCC are all tested. The test also writes known data from the PCC to the mainframe.
This procedure checks the data path be- tween the PCC and the MCC and the PCC code involved in talking to the MCC, by having the PCC write one byte t,o the MCC and read one byte from the MCC.
4-6
DIAGNOSTIC LOOPBACK
OFF BOARD
LOOPBACK TEST
Description of Tests
This procedure loops back 256 bytes of of data as far as the PCC, but not to the DART or the Port Connector assembly.
The data sent is very specific and the PCC expects the bytes in a specified order. If a byte is received out of order, the PCC interrupts the main- frame, During the test the diagnostics check the data and can now see whether the error occurred on the write path to the PCC or on the read path from the PCC.
This procedure reads data from the mainframe and writes i t back to the mainframe through the use of a loopback hood. The read and write paths from and to the mainframe are tested. The test will send 62 bytes to the PCC and then back to the mainframe and the data is compared. This test requires the use of one or more of the supplied loopback hoods.
NOTE: In order to execute this test, you must place the loopback hood on the mini-boards or the AlB. If the loopback hood is placed on the AlB, you must power OFF the Port Connector Assembly via the power switch on the appropriate AlB. (See figure 4-1) This must be done in order to remove the port connector cable from the AlB and place the loopback hood on. When placing the loopback hoods on the mini-boards, the power may be on or off, however, when running the tests, the power out to the junction panel must, of course, be on.
The loopback test can exercise the AlB
or the Port Connectors. If the hood is
placed on the AlB, the SIB and AlB are
tested. If i t is placed on the Port
Connectors, the SIB, AlB and Port Con-
nectors are tested. If the AlB loopback
fails, the ATB is malfunctioning. If
the loopback passes the AlB test, but
the Port Connectors fail, either the
Port Connector cable is bad or a Port
Connector is bad.
Description of Tests
147037·
J1
JUNCTION PANEL POWER SWITCH
•
AIBPCA
J2
RESET SWITCH
Figure 4-1. Location of ALB Power Switch
4-8
ERROR INTERPRETATION I~
ANALYSIS OF TEST RESULTS
As each sub-test is completed, the diagnostic records a pass/fail indication for that sub-test and any
pertinen~information related to it. If a failure has occurred but i t is still possible to proceed with other sub-tests, the diagnostics will do so unless you have previously specified stopping after the first error. At the end of the entire test, the diagnostic analyzes the test data and displays the results. The following examples are a representation of the messages that will be displayed after the tests have completed running.
SIB Test Results
SIB testing completed-without errors
Error(s) were detected during testing Testing of the AlB will not be done.
AlB Test Results
AIBi 0 PASSED
AIBi 1 PASSED
AIBi 2 PASSED
AIBi 3 Port 2 FAILED
AIBi 4 PASSED
AIBi 5 Port 11 FAILED AIBi 6 Port 7 FAILED
of the SIB.
Error Interpretation
The recommended procedure for running the diagnostics is to respond no to the questions prompting for error messages to be printed. However, if you respond yes, the diagnostics will output error messages in three distinct formats. The responses will not be identical to the examples given, but the formats will be very similar. The information given will supply the user with the name of the board tested, the test exercised and the results of the test. Examples of the formats are listed below:
NOTE: These messages will only be displayed if you ask for success/failure messages to be printed. We do not recommend such an action and list the following for informational purposes only.
SIB Test Error Message Example
*** SIB Error Expected: %377:
interrupt FIFO.
In: FIFO (test name)
Received: %357. Bad data read from
SIB Hardware Error Test Example
SIB hardware error detected:
ATP Bus Timeout
AlB Test Error Message Example
AIB# 0 PORT# 1 FAILED Real Loop (test name) Receive buffer did not compare with source buffer.
Expected buffer
o l23456789ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrst Received buffer
Ol234567899ABCDEFGHIJKLM
5-2
Error Interpretation
The following is an example of the diagnostic test results. The SIB is exercised first, followed by the AlB tests.
1MB-SIB communication test Initial Register Value test SIB Memory test
ATP Bus State Sequencing test Timeout test
Board Counter test ATP Bus Buffer test Direct Command test FIFO test
DMA State Counter test DMA Address Counter test
Comp Reg/Address Counter test 1MB Read test
1MB Write test
BeginFlag/LeftRightFlag test
passed passed passed passed passed passed passed passed passed passed passed passed passed passed passed
SIB testing completed - without errors
AIB# 0 PORT# 1 PASSED SELF TEST
AIB# 0 PORT# 1 PASSED DUMP TEST
AIB# 0 PORT# 1 PASSED PCC/MCC/MSC SELF TEST
AIB# 0 PORT# 1 PASSED MCC DUMP TEST
AIB# 0 PORT# 1 PASSED pce MCC TEST
AIB# 0 PORT# 1 PASSED DIAGNOSTIC LOOP
AIB# 0 PORT# 1 PASSED REAL LOOP
AIB# 0 PORT# 2 FAILED SELF TEST
AIB# 0 PORT# 2 FAILED DUMP TEST
AIB# 0 PORT# 2 FAILED PCC/MCC/MSC SELF TEST
AIB# 0 PORT# 2 FAILED MCC DUMP TEST
AIB# 0 PORT# 2 FAILED PCC MCC TEST
AIB# 0 PORT# 2 FAILED DIAGNOSTIC LOOP
AIB# 0 PORT# 2 FAILED REAL LOOP
_ _ T_R_OU_B_LE_S_H_OO_T_IN_G_F_LO_W_C_H_A_RT---il~
1
.
LEOS ON PRESS RESET LEOS OFF ONAIB
FAIL. SHORT OUT PASS
~
FAIL SELF-TEST ONAIB
1
_ _ _ _ _-I~---f1PASS
f
-orENSURE THAT LINE PRINTER ISON LINE POWER OFF
MAINFRAME REPLACE AlB
1
I
POWER ON MAINFRAME
REPLACE POWER OFF _ _ _ SIB MAINFRAME FAIL
LOAD OFF·L1NE DIAGNOSTICS RUN :ATPDIAG
RUN SIB TEST OPTION=ALL OUTPUT TO
LINE PRlNTER PASS
•
FAIL RUN AlB TEST
OPTION=ALL t - - - , NO LOOPBACK
,
PASSFLIP POWER SWITCH ON AlB OFF AND ON TO RESET MOTHER BOARD
PRESS DIAGNOSTIC SWITCH ON MODEM MOTHER BOARD
ATP HARDWARE PASSED DIAGNOSTICS LED OFF ~PASS
_ - . . , . . . - - - -.... PASS
f ••
IF MODEM INSTALLATION REPLACE
MODEM MOTHER BOARD
PLACE POWER SWITCH ON AlB TO OFF POSITION
.-.-
FAIL _ _ _ _ _ _~ O NLEDFAIL RUN AlB TEST
,---...:....;;;,..---1OPTlON=LOOP. WITH HOODS ON PORTS VERIFY RIBBON
REPLACE
f4-- CABLE IS
CABLE SEATED AND
NO THAT THERE ARE GOOD NO BREAKS
GOOD
•
POWER OFF PLACE POWER
MAINFRAME SWITCH ON
REPLACE AIBTOOFF
AlB POSITION
I
1 REMOVE PORTCONNECTOR CABLE HOOD FROM AlB INSTALL AlB LOOPBACK HOOD
POWER OFF
MAINFRAME FAIL RUN AlB LOOPBACK TEST WITH HOOD
REPLACE ONAIB
AlB
I d)A$
1 047037-15
Appendix A
ENSURE POWER SWITCH ON AlB ISOFF RETURN PORT CONNECTOR CABLE HOOD TO AlB
SWITCH MINI·
BOARDS ON BAD JUNCTION PANEL
...---2
REPLACE MODEM MOTHER BOARD PLACE POWER SWITCH ON AlB TO OFF POSITION
+-
NOPLACE POWER SWITCH ON THE AlB IN ON POSITION
RUN AlB TEST OPTION-LOOP,WITH HOODS ON PORTS
FAIL
PLACE POWER SWITCH ON AlB IN THE OFF POSITION
REPLACE CABLE WITH KNOWN GOOD CABLE PLACE POWER SWITCH ON AlB TO THE ON POSITION
PASS. IF MODEM ... INSTALLATION
REPLACE MINI·
BOARDS PLACE POWER SWITCH ON AlB TO OFF POSITION
FAIL LED ON
FLIP POWER SWITCH ON AlB OFF AND ON TO RESET MOTHER BOARD
PRESS DIAGNOSTIC SWITCH ON MODEM MOTHER BOARD LED OFF • PASS FAIL
3--+
B
RUN AlB TEST OPTlON=LOOP, WITH HOODS ON PORTS
PASS
C
A-2
A TP HARDWARE PASSED DIAGNOSTICS
Appendix A
ep
POSSIBLE LOOSE CABLE CONNECTION
•
PLACE POWER SWITCH ON AlB TO OFF POSITION INSTALL OLD CABLE
•
PLACE POWER SWITCH ON AlB TO THE ON POSITION RUN AlB TEST ATP
OPTION =LOOP WITH HOODS
•
PASSED.HARDWARE ON PORTSDIAGNOSTICS
• FAIL PLACE POWER SWITCH ON AlB TO OFF POSITION ATP HARDWARE
+--
REPLACEPASSED CABLE WITH
DIAGNOSllCS PASS THE KNOWN GOOD CABLE
~
PLACE POWER SWITCH ON AlB TO ON POSITION RUN AlB FAIL TEST
3 + - - OPTION=LOOP WITH HOODS ON PORTS
• PASS ATPHARDWARE PASSED DIAGNOSTICS POSSIBLE
LOOSE CABLE CONNECTION
2 RESEAT ALL BOARDS PLACE POWER SWITCH ON AlB TO OFF POSITION
FAIL
RUN AlB PASS
TEST OPTION=LOOP WITH HOODS ON PORTS PLACE POWER SWITCH ON AlB INON POSITION REPLACE BAD MOTHER BOARD WITH KNOWN GOOD MOTHER BOARD PLACE POWER SWITCH ON AlB TO OFF POSITION
LOOPBACK HOODS I~
Figure B-1. HP-Modem B Loopback Hood
Appendix B
1na."Jn-:t"J.14
A B
- r -
o
Figure B-2. AlB Loopback Hood
B-2
Appendix B
Figure B-3, HP DC A and HP DC B Loopback Hoods
WIRING DIAGRAMS I~
/;
3
4
.
~ Is
1 7
2 6
3 8
V
20
~
Figure C-l. \'liring Diagram for
UPDC
BAdapter Cable
Appendix C
I
I I
I
I~
I
I
Figure C-2. Cable Wiring for HP DC A and HP DC B
C-2
A
Advanced Terminal Processor, definition of, v AlB, self-test, 4-5
AlB, test error message example, 5-2 AlB test results, 5-1
AlB, tests, 4-5
Analysis of test results, 5-1 ATP Bus Buffers test, 4-3 ATPDIAG, 2-1
ATP, description of, v
ATP Offline Diagnostic tests, 4-1
B
BeginFlag/Left-Right Flag test, 4-4- Board Counter/Enable test, 4-3
C
Comp/Counter Loopback test, 4-4
D
Diagnostic limitations, 1-5 Diagnostic Loopback test, 4-7 Diagnostic organization, 4-1 Diagnostic tests, 4-1
Diagnostic Utility System, 1-4, 2-1 Dialog, sample, 2-2
Direct Command test, 4-3
DMA Address Counter test, 4-4 DMA State Counter test, 4-3 DUS, 1-4, 2-1
INDEX I
Index
E
Error messages, 2-1
Error message examples, AlB, 5-2, 5-3 Error message examples, SIB, 5-2, 5-3 Execution times, 3-1
F
FIFO test, 4-3
Flow chart, troubleshooting, A-I H
Hardware, required, 1-3 Help messages, 2-1
Hoods, loopback, 1-3
I
1MB-SIB Communication test, 4-2 Information messages, 2-1
Initial Register Values test, 4-2 Instructions, operating, 2-1
L
Limitations, diagnostic, 1-5 Loopbackhoods, 1-3
M
Manual organization, v Messages, 2-1
Modem Controller Chip Dump test, 4-6
Modem Controller Chip Self-Test test, 4-6 Modem Scanner Chip Dump test, 4-6
Modem Scanner Chip, self-test, 4-6 Modem Scanner Chip Self-Test test, 4-6
Index-2
o
Off Board Loopback test, 4-7 Offline organization, 4-1 Operating instructions, 2-1
Organization, offline tests, 4-1
P
PCC-MCC Communication test, 4-6 Philosophy, testing, 1-4
Port Controller Chip Dump test, 4-6
Port Controller Chip Self-Test test, 4-6 Port Controller tests, 4-5
Prompts, 2-1
R
Required hardware, 1-3 Read 1MB test, 4-4 Required software, 1-4
S
Sequencing test, 4-3
SIB, Hardware Error Test example, 5-2 SIB Tests, error messages, 5-2
SIB Memory test, 4-3 SIB Test names, 4-2 SIB Test results, 5-1 Software, required, 1-4
Index
Index
T Testing philosophy, 1-4 Test analysis, 5-1
Test names, AlB, 4-5 Test names, SIB, 4-2 Test results, AlB, 5-1 Test results, SIB, 5-1
Test result examples, AlB, 5-2 Test result examples, SIB, 5-2 Tests, description of 4-1
Tests, offline diagnostics, 4-1 Tests, Port Controllers, 4-5 Tests, SIB, 4-2
Time Out test, 4-3 Times, execution, 3-1
Troubleshooting flow chart, A-I w
Write 1MB test, 4-4
Index-4
STUDENT COMMENT SHEET
We welcome your evaluation of this course material. Your comments Ind suggestions help us improve our courses.
The true test of I course is how well it serves your needs in the months following your trlining. We would appreciate it if. one or two months after attending this ctass. you would respond to the following questions concerning the course material:
How m.ny month.
agodid you take this course?
1
or
I••• 1to 3 3 or more _
Did the m.t.ri.lserv. your needs?
Which topics w.r. more u••ful to you?
Which topics w.,.
I•••t useful to you?
What addition.1 topics would you recommend including in future v.r.ions of this
~,..?Addition.1 comments?
FROM:
Company
Add,...
FOLD FOLD
._---~----~---~---,FIRST CLASS 'ERMIT NO. 10 SANTA CLARA CALIFORNIA
BUSINESS REPLY MAIL
Performance Support Group H.wl.tt.packard Company Computer Systeml Divllion 19447 Prun.ridge Ave.
Cupertino, Califomla 16014
---~---~---~--- fOLD
FOLDSALES & SUPPORT OFFICES
Arranged alphabetically by country
SYdney, New South Wales Office
Hewlett-Packard Australia Ltd.
17-23 Talavera Road P.O. Box 308
NORTH RYDE, N.S.W. 2113 Tel: 888-4444
Telex: 21561
Cable: HEWPARD Sydney A,CH,CM,CS,E,M,P AUSTRIA
Hewlett-Packard Ges.m.b.h.
Grottenhofstrasse 94 A-8052 GRAZ Tel: (0316) 291 5 66 Telex: 32375 CH,E
Hewlett-Packard Ges.m.b.h.
Lieblgasse 1 P.O. Box 72 A-1222 VIENNA Tel: (0222) 23 65 11-0 Telex: 134425 HEPA A A,CH,CM,CS,E,M,P BAHRAIN Green Salon P.O. Box557 Manama BAHRAIN
Tel: 255503-255950 Telex: 84419 P
Wael Pharmacy P.O. Box648 BAHRAIN
Tel:256123 Telex: 8550 WAEL BN E,M
BELGIUM
Hewlett-Packard Belgium S.A.lN.V.
Blvd de la Woluwe, 100 Woluwedal . B-1200 BRUSSELS Tel: (02) 762-32-00 Telex: 23-494 paloben bru A,CH,CM,CS,E,M,P BERMUDA
Applied Computer Technologies Atlantic House Building Par-la-Ville Road Hamilton 5 Tel: 295-1616 P
BRAZIL
Hewlett-Packard do Brasil l.e.C. Ltda.
Alameda Rio Negro, 750 Alphaville
06400 BARUERI SP Tel: (011) 421.1311 Telex: (011) 33872 HPBR-BR Cable: HEWPACK Sao Paulo A,CH,CM,CS,E,M,P ANGOLA
Telectra
Empresa TAEcnica de Equipamentos R. Barbosa Rodrigues, 41-1 DT.
Caixa Postal6487 LUANDA
Tel: 35515,35516 E,P
ARGENTINA
Hewlett-Packard Argentina S.A.
Avenida Santa Fe 2035 Martinez 1640 BUENOS AIRES Tel: 798-5735, 792-1293 Cable: HEWPACKARG A,E,CH,CS,P AUSTRALIA
Adelaide, South Australia Office
Hewlett-Packard Australia Ltd.
153 Greenhill Road PARKSIDE, S.A. 5063 Tel: 272-5911 Telex: 82536
Cable: HEWPARD Adelaide A*,CH,CM,CS,E,M,P Brisbane, Queensland Office
Hewlett-Packard Australia Ltd.
10 Payne Road
THE GAP, Queensland 4061 Tel: 30-4133
Telex: 42133
Cable: HEWPARD Brisbane A,CH,CS,CM,E,M,P Canberra, Australia Capital Territory Office
Hewlett-Packard Australia Ltd.
121 Wollongong Street FYSHWICK, A.C.T. 2609 Tel: 80 4244 Telex: 62650
Cable: HEWPARD Canberra C,CH,CM,CS,E,P Melbourne, Victoria Office
Hewlett-Packard Australia Ltd.
31-41 Joseph Street BLACKBURN, Victoria 3130 Tel: 895-2895
Telex: 31-024
Cable: HEWPARD Melbourne A,CH,CM,CS,E,M,P
Perth, Western Australia Office
Hewlett-Packard Australia Ltd.
261 Stirling Highway CLAREMONT, W.A. 6010 Tel: 383-2188 Telex: 93859
Cable: HEWPARD Perth A,CH,CM,CS,E,M,P SOUTH EAST EUROPE
Hewlett-Packard SA World Trade Center 110 Avenue Louis Carol
1215 Cointrin,GENEV~ Switzerland Tel: (022) 98 96 51
Telex: 27225 hpse.
EASTERN USA Hewlett-Packard Co.
4 Choke Cherry Road ROCKVILLE, MD 20850 Tel: (301) 258-2000 MIDWESTERN USA Hewlett-Packard Co.
5201 Tollview Drive ROLLING MEADOWS, IL 60008 Tel: (312) 255-9800 SOUTHERN USA Hewlett-Packard Co.
2000 South Park Place P.O. Box 105005 ATLANTA, GA 30348 Tel: (404) 955-1500 WESTERN USA Hewlett-Packard Co.
3939 Lankershim Blvd.
P.O. Box 3919 LOS ANGELES, CA 91604 Tel: (213) 506-3700
OTHER INTERNATIONAL AREAS
Hewlett-Packard Co.
Intercontinental Headquarters 3495 Deer Creek Road PALO ALTO, CA 94304 HEADQUARTERS OFFICES
If there is no sales office listed for your area, contact one of these headquarters offices.
AFRICA AND MIDDLE EAST Hewlett-Packard S.A.
Mediterranean and Middle East Operations
Atrina Centre 32 Kifissias Ave.
Paradissos-Amarousion, ATHENS Greece
Tel: 682 88 11
Telex: 21-6588 HPATGR Cable: HEWPACKSA Athens
Product Line Sales/Support Key Key Product Line
A Analytical CM Components
C Computer Systems Sales only
CH Computer Systems Hardware sales and services CS Computer Systems Software sales and services E Electronic Instruments
a
Measurement Systems M Medical ProductsP Personal Computation Products
* sales only for specific product line
** Support only for specific product line
IMPORTANT:These symbols designate general product line capability.They do not insure sales or support availability for all products within aline, at alilocations.Contact your local sales office for information regarding locations where HP support is available for specific products.
HP distributors are printed in italics.
NORTH/CENTRAL AFRICA Hewlett-Packard S.A.
7, Rue du Bois-du-Lan CH-1217 MEYRIN 2, Switzerland Tel: (022) 83 12 12
Telex: 27835 hpse
Cable: HEWPACKSA Geneve ASIA
Hewlett-Packard Asia Ltd.
47IF,26 Harbour Rd., Wanchai, HONG KONG G.P.O. Box 863, Hong Kong Tel: 5-8330833
Telex: 76793 HPA HX Cable: HPASIAL TD CANADA
Hewlett-Packard (Canada) Ltd.
6877 Goreway Drive
MISSISSAUG~Ontario L4V 1M8 Tel: (416) 678-9430
Telex: 610-492-4246 EASTERN EUROPE Hewlett-Packard Ges.m.b.h.
Lieblgasse 1 P.O.Box72
A-1222 VIENNA, Austria Tel: (222) 2365110 Telex: 134425 HEPA A NORTHERN EUROPE Hewlett-Packard S.A.
Uilenstede 475
r;l SALES & SUPPORT OFFICES
L.J Arranged alphabetically by country
l'il
BRAZIL (Cont'd) Hewlett-Packard do Brasil l.e.C. Ltda.
Averiida Epitacio Pessoa, 4664 22471 RIO DE JANEIRO-RJ Tel: (021) 286.0237 Telex: 021-21905 HPBR-BR Cable: HEWPACK Rio de Janeiro A,CH,CM,E,M,P*
Convex/Van Den Rua Jose Bonifacio 458 Todos Os Santos CEP20771 RIO DE JANEIRO, RJ Tel' 249-7121, 591-4946 Telex: 33487
ANAMED I.C.E.I. Ltda.
Rua Bage, 103 04012 SAO PAULO Tel: (011) 570-5726 Telex: 021-21905 HPBR-BR M
CANADA Alberta
Hewlett-Packard (Canada) Ltd.
3030 3rd Avenue N.E.
CALGARY, Alberta T2A 617 Tel: (403) 235-3100 A,CH,CM,E* ,M,P*
Hewlett-Packard (Canada) Ltd.
11120-178th Street EDMONTON, Alberta T5S 1P2 Tel: (403) 486-6666 A,CH,CM,CS,E,M,P British Columbia Hewlett-Packard (Canada) Ltd.
10691 Shellbridge Way RICHMOND,
British Columbia V6X 2W7 Tel: (604) 270-2277 Telex: 610-922-5059 A,CH,CM,CS,E* ,M,P*
Hewlett-Packard (Canada) Ltd.
121 - 3350 Douglas Street VICTORIA, British Columbia V8Z 3L1 Tel: (604) 381-6616
CH,CS Manitoba
Hewlett-Packard (Canada) Ltd.
1825 Inkster Blvd.
WINNIPEG, Manitoba R3H OY1 Tel: (204) 786-6701 A,CH,CM,E,M,P*
New Brunswick Hewlett-Packard (Canada) Ltd.
37 Shediac Road
MONCTON, New Brunswick E1A 2R6 Tel: (506) 855-2841
CH,CS Nova Scotia
Hewlett-Packard (Canada) Ltd.
Suite 111 900 Windmill Road
DARTMOUTH, Nova Scotia B2Y 3Z6 Tel: (902) 469-7820
CH,CM,CS,E* ,M,P*
Ontario
Hewlett-Packard (Canada) Ltd.
3325 N. Service Rd., Unit 6 BURLINGTON, Ontario P3A 2A3 Tel: (416) 335-8644
CS,M*
Hewlett-Packard (Canada) Ltd.
496 Days Road
KINGSTON, Ontario K7M 5R4 Tel: (613) 384-2088 CH,CS
Hewlett-Packard (Canada) Ltd.
552 Newbold Street LONDON, Ontario N6E 2S5 Tel: (519) 686-9181 A,CH,CM,E* ,M,P*
Hewlett-Packard (Canada) Ltd.
6877 Goreway Drive
MISSISSAUGA, Ontario L4V 1M8 Tel: (416) 678-9430
A,CH,CM,CS,E,M,P
Hewlett-Packard (Canada) Ltd.
2670 Queensview Dr.
OTTAWA, Ontario K2B 8K1 Tel: (613) 820-6483 A,CH,CM,CS,E* ,MS,P*
Hewlett-Packard (Canada) Ltd.
1855 Lasalle Boulevard SUDBURY, Ontario, P3A 2A3 Tel: (705) 560-5450 CH
Hewlett-Packard (Canada) Ltd.
220 Yorkland Blvd. Unit #11 WlLLOWDALE, Ontario M2J 1R5 Tel: (416) 499-9333
CH Quebec
Hewlett-Packard (Canada) Ltd.
17500 South Service Road Trans-Canada Highway KIRKLAND, Quebec H9J 2M5 Tel: (514) 697-4232 A,CH,CM,CS,E,M,P*
Hewlett-Packard (Canada) Ltd.
1150 Rue Claire Fontaine QUEBEC CITY, Quebec G1R 5G4 Tel: (4:':8) 648-0726
CH,CS
Hewlett-Packard (Canada) Ltd.
#7-130 Robin Crescent
SASKATOON, Saskatchewan S7L 6M7 Tel: (306) 242-3702
CH,CS CHILE ASCLtda.
Austria 2041 SANTIAGO
Tel: 223-5946, 223-6148 Telex: 340192 ASC CK P,C
Jorge Calcagniy Cia. Ltda.
Av. Italia634Santiago Casilla 16475 SANT/AG09 Tel: 222-0222 Telex: 440283 JCYCL CZ CM,E,M
Metrolab S.A.
Monjitas 454 of. 206 SANTIAGO Tel: 395752, 398296 Telex: 340866 METLAB CK A
Olympia (Chile) Ltda.
Av. Rodrigo de Araya 1045 Casilla 256-V
SANTIAGO 21 Tel: 225-5044 Telex: 340892 OL YMP Cable: Olympiachile Santiagochile CH,CS,P
CHINA, People's RepUblic of
China Hewlett-Packard Co., Ltd.
6th Floor, Sun Hung Kai Centre 30 Harbour Road
HONG KONG Tel: 5-8323211 Telex: 36678 HEWPA HX A,C,CH,CS,E,M,P
China Hewlett-Packard Rep. Office P.O. Box 418
1A Lane2,Luchang St.
Beiwe/ Rd., Xuanwu District BEIJING
Tel: 33-1947, 33-7426 Telex: 22601 CTSHP CN Cable: 1920
A,CH,CM,CS,E,P COLOMBIA InstrumentaciAOn H. A. Langebaek&Kier S.A.
Carrera 4A No. 52A-26 Apartado Aer80 6287 BOGOTA 1,D.E.
Tel: 212-1466 Telex: 44400 INST CO Gable: AARIS Bogota . CM,E,M
Nefromedicas Ltda.
Calle 123 No. 98-31 Apartado Aer80 100-958 BOGOTA D.E., 10
Tel: 213-5267, 213-1615 Telex: 43415 HEGAS CO A
Procesa, S.A.
CRA 7No. 24-89 Piso 25 Torre Colpatria
Apartado Aer80 No. 49667 BOGOTAD.E.
Tel: 2344925, 2344958, 2344742 Telex: 43127 COVER CO C,P
Compumundo Avenida 15# 107-80 BOGOTAD.E.
Tel: 214-4458 Telex: 45466 MARICO P
COSTA RICA Cientifica Costarricense S.A.
Avenida2,Calle 5 San Pedro de Montes de
oca
Apartad0,10159 SAN JOSE
Tel: 24-38-20, 24-08-19 Telex: 2367 GALGUR CR CM,E,M
CYPRUS Telerexa Ltd.
P.O. Box 4809 14C Stassinos Avenue NICOSIA
Tel: 62698
Telex: 2894 LEVIDO CY E,M,P
DENMARK Hewlett-Packard A/S Datavej 52 DK-3460 BIRKEROD Tel: (02) 81-66-40 Telex: 37409 hpas dk A,CH,CM,CS,E,M,P Hewlett-Packard AlS Rolighedsvej 32 DK-8240 RISSKOV, Aarhus Tel: (06) 17-60-00 Telex: 37409 hpas dk CH,E
DOMINICAN REPUBLIC Microprog S.A.
Juan Tomas Mejia y Cotes No. 60 Arroyo Hondo
SANTO DOMINGO Tel: 565-6268
Telex: 4510 ARENTA DR (RCA) P
ECUADOR CYEDE Cia. Ltda.
Avenida Eloy Alfaro 1749 yBelgtca
Casilla 6423 CCI QUITO
Tel: 450-975, 243-052 Telex: 2548 CYEDE ED CM,E,P
Hospitalar S.A.
Robles 625 Casilla3590 QUITO
Tel: 545-250, 545-122 Telex: 2485 HOSPTL ED Cable: HOSPITALAR-Quito M
QUITO Tel: 2-238-951 Telex: 2298 ECUAME ED
EGYPT _
Egyptian International Office for Foreign Trade P.O. Box 2558 42 EI-Zahraa Street Dokki, CAIRO, Tel: 712230
Telex: 93337 EGPOR UN Cable: EGYPOR P,A
SALES & SUPPORT OFFICES 0
Arranged alphabetically by country ~21
EGYPT (Cont'd) INFORMATIC FOR SYSTEMS 22 Talaat Harb Street CAIRO,
Tel: 759006
Telex:93697SAFLM UN CS
International Engineering Associates 24 Hussein Hegazi Street Kasr-el-Aini
CAIRO,
Tel: 23829,21641 Telex: 93830 lEA UN Cable: INTEGASSO E
S.S.C. Medical 40Gezerat EI Arab Street Mohandessin
CAIRO,
Tel: 803844, 805998, 810263 Telex: 20503 SSC UN M-
ELSALVADOR IPESA de EI Salvador S.A.
29Avenlda Norte1216 SAN SALVADOR Tel:26-6858, 26-6868 Telex: 205391PESASAL A,CH,CM,CS,E,P FINLAND Hewlett-Packard Oy Piispankalliontle 17 02200 ESPOO Tel: 00358-0-88721 Telex: 121563 HEWPA SF CH,CM,SS,P
Hewlett-PackardOy (Olarinluoma 7) PL24
02101 ESPOO 10 Tel: (90) 4521022 A,E,M
Hewlett-Packard Oy Aatoksenkatv 10-C SF-40720-72 JYVASKYLA Tel: (941) 216318 CH
Hewlett-Packard Oy Kalnvuntle 1-C SF-90140-140ULU Tel: (981) 338785 CH
FRANCE
Hewlett-Packard France Z.I. Mercure B Rue Berthelot
F-13763 Les Mllles cedex AlI·EN-PROVENCE Tel: (42) 59-41-02 Telex: 410770F A,CH,E,M,P*
Hewlett-Packard France 64, rue Marchand Salliant F-61000 ALENCON Tel: (33) 29 04 42
Hewlett-Packard France Boite Postale 503 F-25026 BESANCON 28 rue de la Republique F-25000 BESANCON Tel: (81) 83-16-22 Telex: 361157 CH,M
Hewlett-Packard France 13, Place Napoleon III F-29000 BREST Tel: (98) 03-38-35 Hewlett-Packard France Chemin des Mouilles Bolte Postale 162
F-69130 ECULLY Cedex (Lyon) Tel: (78) 833-81-25
Telex: 310617F A,CH,CS,E,M
Hewlett-Packard France Pare d'Activite du Bois Briard Ave. du Lac
F-91040 EVRY Cedex Tel: 6 077-8383 Telex: 692315F E
Hewlett-Packard France 5, Avenue Raymond Chanas F-38320 EYBENS (Grenoble) Tel: (76) 62-67-98
Telex: 980124 HP GRENOB EYBE CH
Hewlett-Packard France Centre d'Affaire Paris-Nord Batlment Ampere 5 etage Rue de la Commune de Paris Bolte Postale 300
F-93153 LE BLANC MESNIL Tel: (1) 865-44-52 Telex: 211032F CH,CS,E,M
Hewlett-Packar~France Parc d'Activites Cadera Quartier Jean Mermoz Avenue du President JF Kennedy F-33700 MERIGNAC (Bordeaux) Tel: (56) 34-00-84
Telex: 550105F CH,E,M
Hewlett-Packard France Immueble "Les 3 B"
Nouveau Chemin de la Garde ZAC de Bois Briand F-44085 NANTES Cedex Tel: (40) 50-32-22 Telex: 711085F CH**
Hewlett-Packard France 125, rue du Faubourg Bannier F-45000 ORLEANS
Tel: (38) 68 01 63 Hewlett-Packard France
Hewlett-Packard France Paris Porte-Maillot 15, Avenue de L'Amiral Bruix F-75782 PARIS CEOEX 16 Tel: (1) 502-12-20 Telex: 613663F CH,M,P
Hewlett-Packard France 124, Boulevard Tourasse F-64000PAU
Tel: (59) 80 38 02 Hewlett-Packard France 2 AIIAEe de la Bourgonnette F-35100 RENNES
Tel: (99) 51-42-44 Telex: 740912F CH,CM,E,M,P*
Hewlett-Packard France 98 Avenue de Bretagne F-76100 ROUEN Tel: (35) 63-57-66 Telex: 770035F CH**,CS
Hewlett-Packard France 4 Rue Thomas Mann Boite Postale 56
F-67033 STRASBOURG Cedex Tel: (88) 28-56-46
Telex: 890141F CH,E,M,P*
Hewlett-Packard France Le PAEripole
20, Chemin du Pigeonnier de la CAEpiGEere
F-31083 TOULOUSE Cedex Tel: (61) 40-11-12 Telex: 531639F A,CH,CS,E,P*
Hewlett-Packard France 9, rue Baudin F-26000 VALENCE Tel: (75) 42 76 16 Hewlett-Packard France Carolor
ZAC de Bois Briand F-57640 VIGY (Metz) Tel: (8) 771 20 22 CH
Hewlett-Packard France Immeuble PEricentre
F-59658 VILLENEUVE D'ASCQ Cedex Tel: (20) 91-41-25
Telex: 160124F CH,E,M,P*
GERMAN FEDERAL REPUBLIC
Hewlett-Packard GmbH Geschaftsstelle Keithstrasse 2-4 0-1000 BERLIN 30 Tel: (030) 24-90-86 Telex: 018 3405 hpbln d A,CH,E,M,P
Hewlett-Packard GmbH
Hewlett-Packard GmbH Geschaftsstelle
Emanuel-Leutze-Strasse 1 0-4000 DUSSELDORF Tel: (0211) 5971-1 Telex: 085/86533 hpdd d A,CH,CS,E,M,P Hewlett-Packard GmbH Geschaftsstelle Schleefstr. 28a
0-4600 DORTMUND-Aplerbeck Tel: (0231) 45001
Hewlett-Packard GmbH Vertriebszentrale Frankfurt Berner Strasse 117 Postfach 560 140 0-6000 FRANKFURT 56 Tel: (0611) 50-04-1 Telex: 04 13249 hpffm d A,CH,CM,CS,E,M,P Hewlett-Packard GmbH Geschaftsstelle
Aussenstelle Bad Homburg Louisenstrasse 115 0-6380 BAD HOMBURG Tel: (06172) 109-0 HeWlett-Packard GmbH Geschaftsstelle Kapstadtring 5 0-2000 HAMBURG 60 Tel: (040) 63804-1 Telex: 02163032 hphh d A,CH,CS,E,M,P Hewlett-Packard GmbH Geschaftsstelle Heidering 37-39 0-3000 HANNOVER 61 Tel: (0511) 5706-0 Telex: 092 3259 A,CH,CM,E,M,P Hewlett-Packard GmbH Geschaftsstelle Rosslauer Weg 2-4 0-6800 MANNHEIM Tel: (0621) 70050 Telex: 0462105 A,C,E
Hewlett-Packard GmbH Geschaftsstelle Messerschmittstrasse 7 0-7910 NEU ULM Tel: 0731-70241 Telex: 0712816 HP ULM-O A,C,E*
Hewlett-Packard GmbH Geschaftsstelle Ehhericherstr. 13 0-8500 NURNBERG 10 Tel: (0911) 5205-0 Telex: 0623 860 CH,CM,E,M,P Hewlett-Packard GmbH Geschaftsstelle Eschenstrasse 5