• Aucun résultat trouvé

IMPACT-CO2 Project: Assessment of CO2 health risk in indoor air following a leakage: results from the first representative scale experiment

N/A
N/A
Protected

Academic year: 2021

Partager "IMPACT-CO2 Project: Assessment of CO2 health risk in indoor air following a leakage: results from the first representative scale experiment"

Copied!
2
0
0

Texte intégral

(1)

HAL Id: hal-01372905

https://hal-brgm.archives-ouvertes.fr/hal-01372905

Submitted on 27 Sep 2016

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of sci-entific research documents, whether they are pub-lished or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d’enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

IMPACT-CO2 Project: Assessment of CO2 health risk

in indoor air following a leakage: results from the first

representative scale experiment

Thomas Le Guenan, Fidel Grandia, Annick Loschetter, Louis de Lary de

Latour, E. Powaga, B. Collignan, Manuel Marcoux, Hossein Davarzani,

Olivier Bouc

To cite this version:

Thomas Le Guenan, Fidel Grandia, Annick Loschetter, Louis de Lary de Latour, E. Powaga, et al.. IMPACT-CO2 Project: Assessment of CO2 health risk in indoor air following a leakage: results from the first representative scale experiment. Colloque Franco-Espagnol ”Stockage géologique du CO2 et microfluidique”, Oct 2016, Bordeaux, France. �hal-01372905�

(2)

GEOCO2 – 4-6 octobre 2016, Bordeaux

IMPACT-CO2 Project:

Assessment of CO2 health risk in indoor air following a leakage:

results from the first representative scale experiment.

Le Guenan T*

1

., Grandia F

2

., Loschetter A

1

., de Lary L

1

., Powaga E

3

., Collignan

B

3

., Marcoux M

4

., Davarzani

1

H., Bouc O

1

.

1BRGM, 3 avenue Claude Guillemin, 45100 Orléans, France 2AMPHOS 21, Passeig de Garcia Fària, 49, 08019 Barcelona, Spain

3CSTB, 24 Rue Joseph Fourier, 38400 Saint-Martin d'Hères, France 4 IMFT, 6 allée Emile Monso, 31029 Toulouse, France

*Corresponding author: t.leguenan@brgm.fr,02.38.64.38.53

Keywords :Impact, CO2, building, health, experiment, risk.

Leakage of CO2 from geological reservoirs is one of the most fearsome

unexpected scenarios for CO2 storage activities. If a leakage reaches the ground

level, exposure to high CO2 concentrations is more likely in low ventilated spaces (pit

dug in the ground, basement, building).

We present the first results of the IMPACT-CO2 project that aims at understanding the possible migration of CO2 to indoor environment and to develop

an approach to evaluate this risk. The approach is based on modelling and experiments at laboratory scale and at representative scale. Experiments at representative scale were performed on the PISCO2 platform (Ponferrada, Spain) specifically instrumented and designed for understanding the impacts of CO2

migration at the soil surface. The experiment is composed of a 2.2 m deep basin filled with sand. A specifically designed prototype representing the indoor condition of a building (with controlled depressurization and ventilation) is installed on the basin.

Results show that the presence of thebuilding prototype significantly influences the transport of CO2 in the surrounding soil, leading to two competing

phenomena: 1) seepage in the atmosphere mainly controlled by diffusion gradient and 2) advective/diffusive flux entering the prototype due to its depressurization. Important variations of indoor CO2 concentrations correlated with meteorological

parameters have been evidenced. Thus, a significant part of the study is dedicated to the analysis of the influence of environmental parameters (including atmospheric pressure, depressurization in buildings, soil saturation and temperature) and their respective contribution to the resulting exposure.Models have been established to quantitatively assess the proportion of CO2 entering the building and the resulting

indoor concentrations. Models have then been used to assess a wide range of possible scenarios of exposure for configurations that are representative of inhabited areas at CO2 storage sites.

Acknowledgements: This work was carried out in the framework of the project IMPACT-CO2, co-funded by French Environment and Energy Management Agency (ADEME).

Références

Documents relatifs

• The second has as objects categories with families (cwfs) [8, 11] which support extensional identity types (I-types), Σ-types, Π-types, and are democratic, as arrows

The risk assessment of airborne sensory irritants present in the school leads to the conclusion that reported health complaints are not due to the presence of the measured

131 Charles University, Faculty of Mathematics and Physics, Prague, Czech Republic 132 State Research Center Institute for High Energy Physics (Protvino), NRC KI, Russia 133

Saber (2015) Performance Evaluation of Proprietary Drainage Components and Sheathing Membranes when Subjected to Climate Loads – Task 6 – Hygrothermal Performance of Wall

model of OPLL1 consists of two step: First, the phase noise of v" is modelled, including contributions from the pump RIN and the ASE-induced timing jitter

The graphic titles provide the approximate sweep rate, obtained by dividing the pulse repetition rate (75 MHz) by the product of the number of wavelengths (1024) and the number

In particular, structural comparisons of the Ni(II)-bound CP-Ser structure and our previously reported Ni(II)- and Ca(II)-bound structure reveal conformational changes associated

At the start of each Monte Carlo trial, the following model parameters are randomly sampled: (1) the initial volume of liquid in the Production Reactor, (2) the