Revue des Sciences et de la Technologie - RST- Volume 5 N°1 / janvier 2014

Volume 5, Issue 1, 2014, Pages 50-59

L’impact d’une Charge Fortement Capacitive Sur la Qualitédu Filtrage d’un FAP Contrôlé Par

un Filtre Multi-VariableHautement Sélectif

N. Hamouda, H. Benalla, K. E. Hemsas

Abstract: This article is devoted to the depollution of the electrical supply networks by shunt active power filter (SAPF). We start by studying a self tuning filter (STF) based on Concordia transformation. This transformation is based on the extraction of the references of harmonic currents in the Concordia axis to compensate network harmonic and by consequence, improve the quality of power system. Next, we present the influence of a strongly capacitive load on the quality of the filtering of a SAPF controlled by a STF approach. This influence is validated by numerical simulations under Matlab-Simulink environment of a system of power PD3 a diode debited in a strongly capacitive load this results prove the major influence of this types of load in filtering quality.

Keywords : SAPF, harmonic, STF, System of Power PD3, Quality of Energy, Strongly Capacitive Load, Concordia transformation

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

This part of IEC 61757 defines detail specifications for fibre optic sensors using one or more fibre Bragg gratings FBG as the sensitive element for strain measurements..

Node executing a short path protection request signals an idle request with wrapped status on the short (across the failed span) path and a protection request on the long

This process continues until there are no missing packets, at which time the receiver sends an OK message inside a CONTROL packet to the sender, sets up another

Industrial communication networks – Fieldbus specifications – Part 2: Physical layer specification and service definition.. Réseaux de communication industriels – Spécifications

Radiation protection instrumentation – Recommended climatic, electromagnetic and mechanical performance requirements and methods of tests.. Instrumentation pour la radioprotection

Different types of reliability testing, such as fixed duration, sequential test-to-failure, success test, reliability demonstration, or reliability growth/improvement tests can

La norme européenne détaille la terminologie générale pour les stores intérieurs, les stores extérieurs et les volets. Tels qu’ils sont normalement utilisés et mis en œuvre

La présente Norme internationale est applicable aux protecteurs flexibles isolants destinés à protéger les travailleurs d’un contact accidentel avec des conducteurs électriques