Honeywell MESSAGE SEGMENT FACIUTY PROGRAM LOGIC MANUAL

SERIES 60 (LEVEL 68) MULTICS

RESTRICTED DISTRIBUTIO"!

SUBJECT:

Internal and User Interfaces of the Message Segment Facility.

SPECIAL INSTRUCTIONS:

DATE:

This Program Logic Manual (PLM) describes certain internal modules constituting the Multics System. It is intended as a reference for only those who are thorou~hly familiar with the implementation details of the Multics operating system; interfaces described herein should not be used by application programmers or subsystem writers; such programmers and writers are concerned with the external interfaces only. The external interfaces are described in the Multics Programmers' Manual, Commands and Active Functions (Order No. AG92), Subroutines (Order No. AG93), and Subsystem Writers' Guide (Order No. AK92).

As Multics evolves, Honeywell will add, delete, and modify module descriptions in subsequent PLM updates. Honeywell does not ensure that the internal functions and internal module interfaces will remain compatible with previous versions.

This PLM is one of a set, which when complete, will supersede the System Programmers' Supplement to the Multics Programmers' Manual (Order No. AK96).

THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF HONEYWELL INFORMATION SYSTEMS. DISTRIBUTION IS LIMITED TO HONEYWELL EMPLOYEES AND CERTAIN USERS AUTHORIZED TO RECEIVE COPIES. TH!S DOCUMENT SHALL NOT BE REPRODUCED OR ITS CONTENTS DISCLOSED TO OTHERS IN WHOLE OR IN PART.

F'ebruary 1975 ORDEJi NUfvIBE:H:

AN69, Hev. 0

Références

Documents relatifs

(If the user specified an output_file exit procedure, then the status code data_seq_error is returned to that exit procedure; see the sort_$return entry below.)

Any magnetic tape not written fn the standard format described here is not a Multics standard tape.. Subsequent reels of a multireel sequence also have a tape

Specifies whether an output driver should immediately begin to transmit files and subtrees to the remote system or should instead wait for an operator command

Peripherals include terminals, storage devices (tape drives and disk drives), unit record devices (printers, card punches and card readers), FNPs (described

317 Disk error while trying to swap in data segment 401 InvalId event Channel name passed to Make_Event_Chn 402 No space left in system glObal data area for Open _ Event_ Chn

All otlJer fields are defined for mounted block-stnJctured devices only. Flag set if this device is block-structured. count of copy operations involving this

It is intended as a reference for only those who are thoroughly familiar with the implementation details of the Multics operating system; interfaces described herein should not

str~am5 and VS2 JCL. There is, however, a need to pre-specify SPF library identifiers and file characteristics to SPF/CMS. In SPF/TSO this is the