Update on progress with the radiation thermomethry key comparison CCT-K10

N/A
N/A
Protected

Academic year: 2021

Partager "Update on progress with the radiation thermomethry key comparison CCT-K10"

Copied!
2
0
0

Texte intégral

(1)

https://doi.org/10.4224/23002531

Vous avez des questions? Nous pouvons vous aider. Pour communiquer directement avec un auteur, consultez la

première page de la revue dans laquelle son article a été publié afin de trouver ses coordonnées. Si vous n’arrivez pas à les repérer, communiquez avec nous à PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca.

Questions? Contact the NRC Publications Archive team at

PublicationsArchive-ArchivesPublications@nrc-cnrc.gc.ca. If you wish to email the authors directly, please see the first page of the publication for their contact information.

https://publications-cnrc.canada.ca/fra/droits

L’accès à ce site Web et l’utilisation de son contenu sont assujettis aux conditions présentées dans le site

LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D’UTILISER CE SITE WEB.

READ THESE TERMS AND CONDITIONS CAREFULLY BEFORE USING THIS WEBSITE. https://nrc-publications.canada.ca/eng/copyright

NRC Publications Archive Record / Notice des Archives des publications du CNRC :

https://nrc-publications.canada.ca/eng/view/object/?id=70d052be-3cf0-4079-b167-c13da59ed379 https://publications-cnrc.canada.ca/fra/voir/objet/?id=70d052be-3cf0-4079-b167-c13da59ed379

NRC Publications Archive

Archives des publications du CNRC

For the publisher’s version, please access the DOI link below./ Pour consulter la version de l’éditeur, utilisez le lien DOI ci-dessous.

Access and use of this website and the material on it are subject to the Terms and Conditions set forth at

Update on progress with the radiation thermomethry key comparison CCT-K10

McEvoy, H. C.; Machin, G.; Lowe, D.; Whittam, A.; Sadli, M.; Bourson, F.; Xiaofeng, L.; Martin, M. J.; Gibson, C. E.; Yoon, H. W.; Khromchenko, V. B.; Todd, A.; Woods, D.; Yamada, Y.; Yamaguchi, Y.; Matveyev, M. S.; Taubert, D.; Anhalt, K.; Yoo, YS.

(2)

© NPL M anagemen t Limit ed , 2016. 11719/0616

www.npl.co.uk

APMP region SIM region COOMET region EURAMET region LNE-CNAM CEM PTB VNIIM NRC NIST NPL KRISS NMIJ NIM

Update on Progress with the Radiation

Thermometry Key Comparison CCT-K10

H C McEvoy1, G Machin1, D Lowe1, A Whittam1, M Sadli2, F Bourson2, L Xiaofeng3, M J Martin4, C E Gibson5, H W Yoon5,

V B Khromchenko5, A Todd6, D Woods6, Y Yamada7, Y Yamaguchi7, M S Matveyev8, D Taubert9, K Anhalt9, YS Yoo10

E-mail (corresponding author): helen.mcevoy@npl.co.uk

1 National Physical Laboratory, Teddington, UK

2 Laboratoire Commun de Métrologie, Saint-Denis, France 3 National Institute of Metrology, Beijing, China

4 Centro Español de Metrologia, Madrid, Spain

5 National Institute of Standards and Technology, Gaithersburg, USA

6 National Research Council of Canada, Ottawa, Canada 7 National Metrology Institute of Japan, AIST, Tsukuba, Japan

8 D I Mendeleyev Institute for Metrology (VNIIM), St. Petersburg, Russia 9 Physikalisch-Technische Bundesanstalt, Berlin, Germany

10 Korea Research Institute of Standards and Science, Daejeon, Korea

Background to the comparison

Key comparisons (KCs) are required to ensure equivalence between laboratories and to substantiate Calibration and Measurement Capabilities (CMCs)

The previous radiation thermometry KC (CCT-K5) inished in 1999 and used tungsten ribbon lamps as the transfer instruments. These were not ideal:

their radiance temperature is strongly wavelength dependent, so corrections had to be applied to the results to account for the diferent measurement

wavelengths

the target size of lamps is small (typically 1.5 mm width) compared to the ield-of-view of many radiation thermometers

the inherent uncertainties associated with lamps tend to be large

the upper temperature of the comparison was 1700 °C whereas many laboratories can now achieve up to 2500 °C or even 3000 °C.

The CCT-K10 comparison

A new KC is underway – CCT-K10 – with the transfer instruments being two radiation thermometers (an IKE LP3 and a Chino thermometer IR-RST, both operating at 650 nm), and a set of three High Temperature Fixed-Point (HTFP) blackbody sources (WC-C, Ru-C and either doped Ni-C or doped Co-C); along with a transportable Cu ixed-point unit to determine corrections for any instability of the transfer radiation thermometers.

There are two parts to the KC:

ITS-90 calibration of the two transfer radiation thermometers from 962 °C to 3000 °C using variable high temperature blackbody sources

measurement of the ITS-90 temperatures of the HTFP blackbodies (WC-C (~2750 °C), Ru-C (~1953 °C ) and either doped Ni-C or doped Co-C (both ~1330 °C dependent on doping levels)).

This approach should address the limitations of the previous KC, by extending the

comparison to much higher temperatures, by using methodologies (blackbody sources) which are much less sensitive to measuring wavelength and by using comparison

artefacts which have improved uncertainties compared to the lamps. In addition, the HTFPs are low-uncertainty driftless artefacts which will enable ITS-90 realisation uncertainties to be probed to an unprecedented level.

Schematic of circulation of instruments

Analysis of the results

1) For the radiation thermometer measurements Key Comparison Reference Values (KCRVs) will be determined for each of the comparison temperatures using the

weighted mean with cut-of* of the participant results (i.e. thermometer signal versus ITS-90 temperature) after correcting for any thermometer drift

2) For the HTFP measurements the KCRV will be determined for each HTFP using the

weighted mean with cut-of* of the t90 temperatures of each of the cells

Progress to date with circulation of instruments

NMI Original Timetable Complete?

NPL (pilot) to end Sept 14 ✓ NMIJ mid-Oct 14 to end Nov 14 ✓ NIM mid-Dec 14 to mid-Feb 15 ✓ KRISS Mar 15 to mid-Apr 15 ✓

NPL (pilot) May 15 ✓

NIST mid-June 15 to mid-July 15 ✓

NRC Aug 15 ✓

NPL (pilot) mid-Sept to mid-Oct 15 VNIIM Nov 15 to mid-Dec 15 NPL (pilot) Jan 16

LNE-Cnam mid-Feb 16 to mid-Mar 16

PTB Apr 16

CEM mid-May to mid-June NPL (pilot) July 16 to Aug 16

Issues/challenges

The comparison is currently running about 10 months behind the original schedule due to customs/ transportation delays, issues within particular

laboratories and issues with the circulating equipment, and is now currently due to inish around the end of June 2017

The doped Ni-C cells, which were originally chosen for one of the HTFP

types, sufered several breakages so this HTFP type has been replaced with a doped Co-C cell. This will introduce an extra challenge with linkage between participants

The transfer radiation thermometer results will need to be corrected for drift based on the results of the Cu point checks, and this is likely to be a signiicant correction.

Graph 1: Stability of the KC radiation thermometer A, based on the Cu ixed point checks.

Graph 2: Stability of the KC radiation thermometer B, based on the Cu ixed point checks. Figure 2: A high temperature ixed-point blackbody Figure 1: The Chino IR-RST radiation thermometer Figure 3: The Linear Pyrometer LP3

APMP – Asia Paciic Metrology Programme

EURAMET – European Association of Metrology Institutes

COOMET – Euro-Asian Cooperation of National Metrological Institutions SIM – Inter-American Metrology System

(* the weight is 1/u2 where u is the standard uncertainty of the participant’s measurements at the comparison temperature, or for the HTFP measurements. The

cut-of values for the weights will be the average of the uncertainty values of those participants that reported uncertainties smaller than or equal to the median uncertainty of all the participants.)

View publication stats View publication stats

Références

Documents relatifs

Nonlinear conversion of visible and IR lasers in vapors (crystals are not transparent enough in this domain) has been extensively studied since the 70’s; in this context mercury

In this paper we describe the experiment which has verified the black body character of the spectrum of the cosmic background radiation on the high frequency side of the peak

CONSTRUCTION AND TEST OF A CHANNELING-RADIATION SOURCE AT THE NEW DARMSTADT SUPERCONDUCTING ELECTRON

The documents may come from teaching and research institutions in France or abroad, or from public or private research centers.. L’archive ouverte pluridisciplinaire HAL, est

At this point this work is articulated around four axes of studies in the domain of physical characterization and modelisation of radiation of instruments, perception, sound

The results show that measurements of the reference blackbody for cavity temperatures above 0 8 C reported by radiometers that include internal blackbodies exhibit superior

The PRE plate results more efficient in sound radiation and transmission control than a viscoelastic plate, and it is also important to denote that the piezoelectric layer is