• Aucun résultat trouvé

Theranostic body fluid cleansing: rationally designed magnetic particles enable capturing and detection of bacterial pathogens

N/A
N/A
Protected

Academic year: 2021

Partager "Theranostic body fluid cleansing: rationally designed magnetic particles enable capturing and detection of bacterial pathogens"

Copied!
2
0
0

Texte intégral

(1)

ELECTRONIC SUPPORTING INFORMATION

Theranostic Body Fluid Cleansing: Rationally designed Magnetic

Particles enable Capturing and Detection of Bacterial Pathogens

M. Lattuada, Q. Ren, F. Zuber, M. Galli, N. Bohmer, M.T. Matter, A. Wichser,

S. Bertazzo, G.B. Pier and I.K.

Herrmann*

*Department Materials Meet Life,

Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5,

9014 St. Gallen, Switzerland.

(2)

Figure S1: Bacteria samples incubated with PNAG-PAG-MNP show normal growth rate compared to

controls (no beads)(a). Measurements of re-growth of S. aureus in the untreated supernatant (no beads)

and on collected beads show enrichment of bacteria on the beads (b).

Bacteria viability quantification with proliferation test (Re-growth). 100 μl of the resuspended beads was

mixed with 900 μl fresh 30 % TSB (9 g/l) containing 0.25% glucose. 200 μl of the mixture was added to a micro-plate well (3 repeats) and the micro-plate was closed with a sticking transparent foil (Diversified Biotech - Breathe-Easy, T093.1, Carl Roth GmbH+Co. KG) and incubated in a Synergy HT Multi-Detection Microplate Reader (BioTek®) at 37 °C and medium shaking (18Hz - preset value of the instrument). Optical density at 600 nm was measured every 30 min for 14 hours. For each sample, two independent experiments were performed.

Figure

Figure S1:  Bacteria samples incubated with PNAG-PAG-MNP show normal growth rate compared to  controls (no beads)(a)

Références

Documents relatifs

during compensatory growth; BWG, body weight gain (g); FI, feed intake total (g); FCR, feed 566. conversion ration; and RFI, residual

If a more viscous fluid is used for the film, for the same added mass, the decrease of the frequencies are equivalent to those observed with water, but less damping are observed :

mechanism to the orientational ordering of the system. This coupling is determined by the aspect ratio of the rods and the plates, which is the only relevant microscopic parameter.

This research was funded by the Eu- ropean Space Agency (ESA) in the framework of the Data User Programme (DUP), contract DAMS2P (Development of Global Aerosol Mapping

Comme la structure de nos échantillons nous est suffisamment connue (ce sont des graphites synthétiques qui cristallisent dans le système hexagonal), nous ne nous

In order to examine whether stereoscopic depth information could drive fast automatic correction of hand pointing, an experiment was designed in a 3D visual environment in

The objective of this study is to experimentally measure adhesion strength between ice and concrete with various applied pressure and contact duration time under constant

It was hypothesized that the vignette character with obesity would face greater stigma in terms of stereotypes, prejudice, and discrimination compared to vignette characters