K300-NZM 10 K2x120-NZM 10 K2x240-NZM 10 RG-NZM 10 K2x240W-NZM 10 K2x240 IP-NZM 10
P10(4)-...
NZM 10(4)-...N/B
NZM 10(4)-...(N)(S)(H) /ZM (M, V)-...
(-NA)
OFF ON
TRIP
10 mm 5 mm
PZD 2 Ø 2 mm
11/95 AWA123-1089 Montageanweisung Installation Instructions Notice d installation
Istruzioni per il montaggio Instrucciones de montaje
Electric current! Danger to life!
Only skilled or instructed persons may carry out the following operations.
The national regulations/specificationes must be observed for the installation of the devices.
Tension lectrique dangereuse !
Seules les personnes qualifi es et averties doivent ex cuter les travaux ci-apr s.
Veuillez respecter les normes de mise en oeuvre sp cifiques aux diff rents pays.
Tensione elettrica: Pericolo di morte!
Solo persone abilitate e qualificate possono eseguire le operazione di seguito riportate.
Per l installazione degli apparecchi necessario rispettare le normative specifiche di ciascun paese.
`Corriente el ctrica! `Peligro de muerte!
El trabajo a continuaci n descrito debe ser realizado por personas cualificadas y advertidas.
Para la instalaci n de los aparatos han de tenerse en cuenta las normativas/especificaciones a nivel local.
Lebensgefahr durch elektrischen Strom!
Nur Elektrofachkr fte und elektrotechnisch unterwiesene Personen d rfen die im Folgen- den beschriebenen Arbeiten ausf hren.
Beachten Sie f r die Installation der Ger te die l nder- spezifischen Vorschriften.
75
210 280
70
4P
4 M6x50
1:2
3P
143,5124 245 250 286
90°
90°
90°
90°
OFF ON
TRIP
OFF ON
TRIP
min. 130 mm
11/95 AWA123-1089
A B
B A
OFF ON
TRIP
OFF ON
TRIP
OFF
OFF ON
TRIP
1 2
3
2 3
Montage Mounting Montage Montaggio Montaje
Auslöseblock Trip block
Unité de déclenchement Sganciatore
Bloque de disparo
ZM (M)(V)/B
1
11/95 AWA123-1089
OFF ON
TRIP
OFF ON
TRIP
A
B
OFF ON
TRIP
I
rOFF ON
TRIP
t
rOFF ON
TRIP
I
rmvOFF ON
TRIP
B-NZM ZM...
4 5
1 2
3 4
Einstellungen Adjustments Réglages Regolazioni Regulaciones
ZM (M)(V)/B
lr
6xlr
tr
tr=20s tr=6s
Irm
Irmv
tv
I>
I> I>
lr
6xlr
tr
tr=20s tr=6s
Irm
Irmv
tv
I>
I>
I>
lr
6xlr
tr
tr=20s tr=6s
Irm
Irmv
tv
I>
I>
I>
11/95 AWA123-1089
TRIP
tripped
push to trip
OFF TRIP
OFF ON
TEST 1 TEST 2
OFF ON
TRIP
A
B
OFF ON
TRIP
t
vOFF ON
TRIP
I
rm5 6
7 8
lr
6xlr
tr
tr=20s tr=6s
Irm
Irmv
tv
I>
I> I>
lr
6xlr
tr
tr=20s tr=6s
Irm
Irmv
tv
I>
I>
I>
Thermisches Gedächtnis - Verbraucher- und Anlagenschutz Nach Auflösung durch Überstrom ist der NZM 10 nach x Minuten wieder einschaltbereit.
Thermal memory - user/system protection
The NZM 10 is ready for closing x minutes after it has been tripped due to overcurrent.
Mémoire termique - protection des récepteurs et installations Après déclenchement sur surcharge, le NZM 10 peut être réarmé au bout de x minutes.
Memoria termica - protezione utillizzatori ed impianti A seguito di sgancio dovuto a sovracorrenti, l’NZM 10 può essere reinserito dopo x minuti.
Memoria térmica - protección del usuario y del sistema El NZM 10 está perparado para cerrar x minutos después de haberse disparado por sobreintensidad.
11/95 AWA123-1089
OFF ON
TRIP
OFF
SVB-NZM 10
OFF ON
TRIP
A
B
OFF ON
TRIP
A
B
OFF ON
TRIP
B
OF TRIP
A
Ø 6...8 mm max. 3x
1
3
2
Anschlüsse Connections Connexions Collegamenti Conexiones
TEST 3
11/95 AWA123-1089
A B
B
A 10 mm
B
A
10 mm 50 Nm
B A
K22 x 21
K2 x 120 K2 x 240 K300
S S
S
K22 x 21 K300
K2 x 240 K2 x 120
Steuerleitungen Control cables Câbles de commande Cavi comandi Cables de control
1 2
3 4
S: 1x 120-300 mm2
1x 50-240 mm2 S: 2x 50-240 mm2 1x 70-120 mm2
S: 2x 70-120 mm2 10x16x0,8
11x21x1,0 2(11x21x1,0)
11/95 AWA123-1089
B
5 mm 8 Nm
A
B
5 mm 8 Nm
A
B 5 mm
8 Nm
A
B
5 mm 8 Nm
A
C B
A
5 mm 8 Nm
C
1
1 2
1 2
K22x21-NZM10
K300-NZM10
K2x120-NZM10
11/95 AWA123-1089
B
A
10 mm
50 Nm B
A
8 mm 50 Nm
B
C A
B
A
B
C A
1 2
3
1 2
K2x240-NZM10
K2x240IP-NZM10
11/95 AWA123-1089
A
B 10 mm
C B A
OFF ON
TRIP
70
254
Ø 43
A
B C
1 2
3 4
A
C
B
1 K2x240W-NZM10
RG-NZM10
11/95 AWA123-1089
Current Limiting Data according to UL 489
Instructions for Field Wiring
Terminal Kit System for NZM 10 (C)NA and NZM 10 N/B-NA
Circuit Breaker Threshold Current
Circuit Breaker Wire Size Max. A-Rating TighteningTorque
Intermediate Current High Interrupting Capacity Frequency
Type
Bolt-on
Terminal Cover (3) 2Z1213-651.28 L1; L2; L3 600 A 50 Nm
K2x240W-NZM 10 K2x240IP-NZM 10
Terminal Cover (3) 2Z123-651.28 Insulating Plate (1) 4Z 123-651.1003
Auxiliary Terminal
2xAWG2-2x500MCM
AWG 18-14
50 Nm
1,2 Nm Cu + Al
Cu only
Cu only
600 A
500 A
350 A K2x120-NZM 10
Auxiliary Terminal
2xAWG3/0-2x250MCM
AWG 18-14 K300-NZM 10
Auxiliary Terminal
250MCM-500MCM
AWG 18-14
NZM10H 600
Max. Frame Size A
RMS SYM kA
Peak kA
I2dt 103A2s MAXIMUM
RMS SYM kA
Peak kA
I2dt 103A2s MAXIMUM
RMS SYM kA
60 Hz Voltage (V) Peak
kA
I2dt 103A2s MAXIMUM
39 39 39
125 65 42
200 100 50 34.0
42.0 40.0
2800 5500 5500
50.0 52.0 45.0
3500 6600 7200
55.0 61.0 48.0
4000 8000 8000
240 480 600
8 Nm 1,2 Nm
8 Nm 1,2 Nm
Moeller GmbH,Industrieautomation, 53105 Bonn nderungen 11/95 AWA123-1089 10004851/0013 FD
11/11
11/95 AWA123-1089
1/1
Achtung Auslaufprodukt!
Note: Discontinued Product!
Note : Produit en fin de commercialisation ! Prodotto in obsolescenza!
Nota: Producto substituido.
Atenção: produto de fim de série!
Bitte bestellen Sie zukünftig das Nachfolgeprodukt NZM1, -2, -3, -4.
Please order the up to date NZM1, -2, -3, -4 product in the future.
Merci de commander le produit de remplacement NZM1, -2, -3, -4.
Vi invitiamo ad ordinare in futuro il nuovo prodotto alternativo NZM1, -2, -3, -4.
En próximos pedidos indique la referencia actual NZM1, -2, -3, -4.
Por favor, encomendem no futuro o produto sucessor NZM1, -2, -3, -4.
NZM7-..., P7-..., NZM10-..., P10-...