• Aucun résultat trouvé

Patient-specific finite element model of the buttocks for pressure ulcer prevention - linear versus non-linear modelling

N/A
N/A
Protected

Academic year: 2021

Partager "Patient-specific finite element model of the buttocks for pressure ulcer prevention - linear versus non-linear modelling"

Copied!
3
0
0

Texte intégral

(1)

HAL Id: hal-00738868

https://hal.archives-ouvertes.fr/hal-00738868

Submitted on 5 Oct 2012

HAL is a multi-disciplinary open access

archive for the deposit and dissemination of

sci-entific research documents, whether they are

pub-lished or not. The documents may come from

teaching and research institutions in France or

abroad, or from public or private research centers.

L’archive ouverte pluridisciplinaire HAL, est

destinée au dépôt et à la diffusion de documents

scientifiques de niveau recherche, publiés ou non,

émanant des établissements d’enseignement et de

recherche français ou étrangers, des laboratoires

publics ou privés.

Patient-specific finite element model of the buttocks for

pressure ulcer prevention - linear versus non-linear

modelling

Marek Bucki, Vincent Luboz, Claudio Lobos, Nicolas Vuillerme, Francis

Cannard, Bruno Diot, Yohan Payan

To cite this version:

(2)

*Corresponding author. Email: Marek.Bucki@TexiSense.com

Patient-specific Finite Element Model of the Buttocks for

Pressure Ulcer Prevention – Linear vs Non-Linear Modeling

M. BUCKI

1*

, V. LUBOZ

2

, C. LOBOS

3

, N. VUILLERME

4

, F. CANNARD

1

, B. DIOT

5

and Y. PAYAN

2

1

TexiSense, Montceau-les-Mines, France,

2

TIMC-IMAG laboratory, Joseph Fourier University, La Tronche,France,

3

Universidad Tecnica Federico Santa Marıa, Santiago, Chile,

4

AGIM Laboratory, CNRS-UJF-UPMF-EPHE, 38706 La Tronche, France,

5

IDS, Montceau-les-Mines, France.

Keywords: Biomechanical modeling, Patient-specific models, Finite Element Method, Pressure ulcer prevention

1 Introduction

Currently available techniques and/or protocols designed to prevent pressure sore formation in persons with spinal cord injury and wheelchair users are mainly based on the improvement of the skin/support interface and on a postural and behavioral education. These techniques however, seem to lack efficiency as the prevalence and incidence of pressure sore still remains very high. Development and validation of efficient solutions to prevent pressure sore is thus strongly needed. Deep tissue sores stem from internal overpressures within the soft tissues [1]. Unfortunately only external pressures, at the interface between the skin and the cushion, can be measured by the available sensors. Yet, internal stresses can be estimated from the values of external interface pressures by resorting to biomechanical modeling. This article outlines a methodology aiming at the definition of an individual and personalized pressure ulcer risk assessment scale based on patient-specific biomechanical modeling.

2 Methods

Internal overpressures tend to develop near bony prominences thus the focus is usually made on the ischia and the sacrum when considering wheelchair bound subjects [1]. Our methodology assumes that the shape of these bony features as well as the external surface of the patient’s buttocks can be acquired through medical imaging such as CT-scanner or the novel EOS modality [2]. From this data, a hexahedral-dominant Finite Element (FE) mesh is generated as described below. Hexahedral meshes used in conjunction with the FE method usually yield accurate and numerically stable solutions. However, one of the most common pitfalls in hexahedral meshing is the issue of accurate representation of the organ inner and outer surfaces. In order to produce an accurate FE mesh, our method relies on a small set of simple and synthetic “template patterns” that describe how the hexahedra intersecting the domain boundary should be optimally subdivided into mixed elements [3].

The meshing algorithm starts from a hexahedral grid. Each hexahedron intersecting the bone or skin boundary is analyzed and the best-suited meshing pattern is applied. Depending on the local surface configuration, the hexahedron is replaced by a combination of prisms, pyramids and/or tetrahedra that maximizes the surface representation accuracy. An example of FE mesh produced by our method is shown in Fig. 1. Bone and skin surfaces are shown in transparency along with the FE mesh. This model takes into account a number of morphological parameters such as the anteversion or retroversion of the pelvis, the curvature of the ischia, the shape of the sacrum and the soft tissue thickness below the hip level. To reduce computational time the mesh is “clipped” and only the soft tissues below the patient’s hips are modeled (see Fig. 1 – right).

Figure 1 – FE mesh of a subject’s buttocks in a seated position (axial and sagittal view).

(3)

lying on the horizontal clip plane passing through the hips are also fixed. The pressure patterns recorded under the buttocks by the TexiSense sensor are applied as normal pressures on the skin nodes in contact with the cushion. Based on the results of this personalized biomechanical study, a tailor-made ulcer prevention strategy can be designed and implemented in a personalized prevention device [4]. FE analysis is a costly numerical method. The mesh shown in Fig. 1 comprises 7591 elements and 5279 nodes. Given this number of degrees of freedom, the computation of a fully non-linear simulation (large displacements and large deformations) takes several minutes on a desktop computer. This is clearly not compatible with a real-time prevention strategy. The linear modeling framework (small displacements and small deformations), although less accurate, makes it possible to estimate the internal stresses in real time [5]. In this study a non-linear Mooney-Rivlin material (C10=1.65kPa, C01=3.35kPa, bulk modulus K=500kPa [6]) was compared to its “tangent” linear model (E=9.9kPa, ν=0.49). The FE analysis was performed using the Artisynth software [7].

3 Results and Discussion

Estimations of von Mises stresses at the ischial tuberosity based on recorded surface pressure values underneath the ischium have been computed. Figure 2 and Table I summarize the results for five external pressure values applied to the skin.

Figure 2 – Upper curve: non-linear, lower: linear.

SKIN LIN. NON-LIN.

25.1

123.6

118.1

68.8

355.7

357.3

128.0

695.3

710.6

196.6

1126.0

1159.5

269.3

1633.3

1672.8

Table 1 – Skin pressures and internal stresses (kPa).

4 Conclusions

The linear model underestimates the internal stresses in all but one case, yet the error is smaller than 5% of the non-linear reference value. This

indicates that linear modeling of the buttocks soft tissues might be suitable for a real-time personalized ulcer prevention strategy using a von Mises-based indicator of the level of tissue damage. The presented modeling method seems well suited for handling individual morphologies although some limitations exist. First, it is difficult to acquire an unconstrained “resting shape” of the buttocks. Initial stresses should thus be taken into account in order to gain accuracy. Second, our model overestimates the buttocks stiffness as it only considers the gluteal muscles and ignores the fat layer. This parameter should be integrated within the model as it affects the outcome of the analysis.

References

[1]

Makhsous M., Lim D., Hendrix R.,

Bankard J., Rymer W.Z.,

and

Lin F.,

Finite element analysis for evaluation of pressure ulcer on the buttock: development and validation, IEEE Trans Neural Syst Rehabil

Eng., vol. 15, pp.517-525, 2007.

[2]

Dubousset J., Charpak G., Skalli W., De

Guise J.A.,

and

Kalifa G.,

EOS: A new imaging system with low dose radiation in standing position for spine and bone & joint disorders. Journal of Musculoskeletal Research,

vol. 13(1), pp.1-12, 2010.

[3]

Yerry M.A.,

and

Shephard M.S.,

Automatic Three-dimensional Mesh Generation by the Modified-Octree Technique.

International Journal for Numerical Methods in Engineering, vol. 20, pp.1965-1990, 1984. [4]

Chenu O., Payan P., Hlavackova P.,

Bucki M., Diot B., Cannard F.,

Demongeot J.,

and

Vuillerme N.,

System for pressure sore prevention: a user-centered design. In Proceedings of the 14th Annual European Pressure Ulcer Meeting Oporto, Portugal, 2011.

[5]

Cotin S., Delingette H.,

and

Ayache N.,

Real-time elastic deformations of soft tissues for surgery simulation. IEEE Trans. on Vis. and

Comp. Graphics, vol. 5(1), pp.62-73, 1999.

[6]

Verver M. M., van Hoof J., Oomens C.

W., Wismans J. S.,

and

Baaijens F. P.,

A finite element model of the human buttocks for prediction of seat pressure distributions. Comput

Methods Biomech Biomed Engin, vol. 7,

pp.193-203, 2004.

[7] http://www.magic.ubc.ca/artisynth

Acknowledgments

Références

Documents relatifs

Weakly nonlinear viscoelastic Landau’s theory, widely used in acoustical physic, is introduced into a Finite Element formulation to model the nonlinear behaviour of finite

Hild, Hybrid analytical and extended finite element method (HAX-FEM) : a new enrichment algorithm for cracked solids, International Journal for Numerical Methods in Engineering

As a last example, the linear smoothing technique is extended to three dimensional domain with a through-the-thickness edge crack subjected to uniform tensile stress as shown in

To retrieve landmarks on a new image, the cranial contour is detected and sampled, cephalograms are registered and the mean shape model is used to estimate the

This papers presents a methodology to build reduced order linear parameter varying (LPV) models of soft robots based on a finite element model.. A linear controller is then designed

Keywords: Foot pressure ulcer; Soft tissues; Patient-Specific; Finite element method.. This

Methods: Estimating internal strains within soft tissues could help to evaluate the risk of pressure  ulcer.  A  subject‐specific  biomechanical  model  could 

Our biomechanical Finite Element (FE) foot atlas [2] is divided into eight anatomical regions: Achilles tendon, ankle, heel, medial foot, first metatarsus, four other