Fracture Strength of Endodontically Treated Teeth Restored with Composite Overlays with and without Glass-fiber Reinforcement

Carlo Monaco

a

/ Antonio Arena

b

/ Roberto Scotti

c

/ Ivo Krejci

d

Purpose: To evaluate the fracture strength and the failure mode of endodontically treated teeth restored with com- posite resin overlays with and without glass-fiber reinforcement.

Materials and Methods: A total of 32 extracted molars were divided into four equal groups. In the NFR-NFRC (no foundation restoration, no fiber-reinforced composite) and NFR-FRC (no foundation restoration, fiber-reinforced com- posite) groups, only a 5-mm-thick composite resin layer sealed the pulp chamber floors, whereas in the FR-NFRC (foundation restoration, no fiber-reinforced composite) and FR-FRC (foundation restoration, fiber-reinforced compos- ite) groups, a 3.0-mm foundation restoration was used. NFR-NFRC and FR-NFRC groups were restored with compos- ite resin overlays, whereas NFR-FRC and FR-FRC groups were restored with fiber-reinforced composite resin overlays. All specimens were subjected to mechanical loading in a computer-controlled masticator and then the fracture resistance was evaluated. Differences in means were compared using two-way ANOVA and Tukey’s test.

The level of significance was set at _ = 0.05.

Results: All specimens successfully completed the fatigue test. The least fracture-resistant group was NFR-FRC, ex- ceeded by FR-NFRC, NFR-NFRC, and FR-FRC, in that order, with FR-FRC being the most fracture-resistant group. Sta- tistically significant differences were detected between the pairs NFR-NFRC/FR-FRC (p = 0.001), NFR-FRC/FR-FRC (p = 0.001), and FR-NFRC/FR-FRC (p = 0.001). Eight vertical root fractures occurred in group FR-NFRC, six in group NFR-NFRC, four in group NFR-FRC, and none occurred in group FR-FRC.

Conclusions: Within the limitations of this in vitro study, the incorporation of glass fibers and the presence of a foundation restoration were found to increase the fracture resistance and can favorably influence the fracture mode.

Keywords: molars, resin-bonded onlays, root fractures.

J Adhes Dent 2016; 18: 143–149. Submitted for publication: 22.08.15; accepted for publication: 08.01.16 doi: 10.3290/j.jad.a35908

a Assistant Professor, Division of Prosthodontics and Maxillofacial Rehabilita- tion, Department of Biomedical and Neuromotor Sciences, University of Bolo- gna, Bologna, Italy. Wrote the manuscript, prepared the specimens, performed the microscopic observations.

b Researcher, Division of Prosthodontics and Maxillofacial Rehabilitation, De- partment of Biomedical and Neuromotor Sciences, University of Bologna, Bo- logna, Italy. Wrote the manuscript, performed the fracture test.

c Professor, Division of Prosthodontics and Maxillofacial Rehabilitation, Depart- ment of Biomedical and Neuromotor Sciences, University of Bologna, Bolo- gna, Italy. Supervised the study, contributed to discussion and conclusions.

d Professor, Division of Cariology and Endodontics, School of Dentistry, Univer- sity of Geneva, Switzerland. Supervised the study, contributed to the experi- mental design and discussion.

Correspondence:Dr. Carlo Monaco, Division of Prosthodontics and Maxillofacial Rehabilitation, Department of Biomedical and Neuromotor Sciences, University of Bologna, Via San Vitale 59, 40125 Bologna, Italy. Tel: +39-051-208-8186; e-mail:

carlo.monaco2@unibo.it

T

he restoration of pulpless teeth is still a much-debated topic.13 In recent years, important developments have taken place in the field of adhesive dentistry, due to the

concept of minimal invasivity.24,25 Clinical studies have shown that the more tooth tissue can be preserved, the greater the chance the tooth has of fulfilling its function over the long term.5,8

The amount of remaining tooth structure in vital teeth after caries, trauma, or previous restorations should deter- mine how the tooth must be restored.12 This is also true for endodontically treated teeth. The resistance of endodonti- cally treated teeth restored with composite resins is affected mainly by the number of residual walls.28 In cases with suf- ficient remaining tooth structure, especially if intact enamel is still present, the use of indirect adhesive restorations with- out posts may present an interesting alternative to conven- tional treatment concepts.30 This approach is the most con- servative for both the crown and the root. Nevertheless, in cases of strong loading or fatigue stress, a restoration can fracture and, due to strong adhesion between the restoration and tooth, a crack can occur along the bonding interface and propagate towards the root, leading to irreparable failure.37

(2)

A careful approach, considering the variability among in- dividual cases and a solid knowledge of the biomechanical peculiarities of endodontically treated teeth, is always nec- essary. After root canal treatment, teeth are more suscep- tible to fracture. The principal reason for this structural weakening is the removal of the tooth structure during the endodontic procedures.22 The strength of the tooth de- pends on the amount of remaining hard dental tissues.27 Thus, attention should be paid to protect structurally com- promised teeth from fracture. Root canal treatment should not be considered complete until the permanent coronal restoration has been placed.40 The functional and morpho- logical integrity of the tooth is usually restored by intracoro- nal restoration or fixed dental prostheses.34

Currently, the best approach for restoring endodontically treated teeth seems to be to (1) minimize tissue sacrifice, especially in the cervical area, so that a ferrule effect can be created, (2) use adhesive procedures at both the radicu- lar and coronal levels to strengthen the remaining tooth structure, and (3) use post and core materials with physical properties close to those of natural dentin.9

The principal function of a post is to provide intracoronal retention of the core/crown restoration and to distribute func- tional loads to a larger area of the remaining tooth struc- ture.14 However, posts do not strengthen endodontically treated teeth:1,2,36,38 If reinforcement is desired, it should be through incorporating a ferrule into the design of the crown, embracing the circumference of the root to protect the root where maximum force occurs. The ferrule effect is a key factor in the failure threshold of post-treated teeth, but the same ferrule preparation also causes loss of important re- maining hard dental tissues.3,16,33 The literature demon- strates that a ferrule is desirable, but should not be provided at the expense of the remaining tooth/root structure.35

While the traditional method includes several drawbacks, such as the sacrifice of a considerable amount of sound structure and the longer treatment time necessary for these complex restorations (which makes them costly), adhesive restorations ensure retention and fracture resistance with maximal conservation of dental tissue.12,31 Longevity of

restorations in stress-bearing posterior cavities depends on many factors, including the materials, the dentist, and the patient. The dental literature reports that annual failure rates of posterior composite resin inlays and onlays range from 0% to 10%, indicating that indirect posterior restor- ations are a long-lasting alternative in the rehabilitation of large defects.21

The development of fiber-reinforced composite resin technologies has increased the field of application of com- posite resin materials. Glass fibers have demonstrated a significant ability to withstand tensile stress and to stop crack propagation in composite resin materials.19,39 The use of fiber-reinforced composite resin (FRC) may prevent undesirable subgingival fracture, and may have a beneficial effect on the failure mode of composite resin restorations and on reparability in the event of a fracture.23

To date, only a few studies have been published on this topic.4,7,17,20 The purpose of this study was to evaluate the fracture strength and the failure mode of endodontically treated posterior teeth restored with composite resin over- lays with and without reinforcement with glass fibers in dif- ferent cavity configurations. The null hypothesis is that the presence or absence of reinforcement and a foundation res- toration do not have influence on marginal adaptation and failure modality.

MATERIALS AND METHODS

A total of 32 caries-free extracted mandibular molars of nearly identical size with completed root growth were se- lected. The teeth were extracted due to periodontal disease (patient age range 46 to 79 years) and were stored at 4°C in a solution of 0.02% thymol from the time of extraction up to a maximum of 3 months. Their use complied with the rules of the Commission of Ethics for Research on Humans at the University Hospital of Geneva. The teeth were divided randomly into four equal groups. All teeth were treated end- odontically, and the root canal preparations were performed using NiTi rotary instruments (Protaper, Denstply Maillefer;

Ballaigues, Switzerland) in a low-speed handpiece (Tecnika, Denstply Maillefer) under intermittent rinsing with 5% NaOCl (Niclor 5, Ogna; Muggiò, Italy). An epoxy sealer (AH Plus, Dentsply De Trey; Konstanz, Germany) and warm gutta-per- cha (Gutta-percha Points, Denstply Maillefer) in association with a vertical condensation technique (System B, Sybron Dental; Orange, CA, USA) were used to fill the canal system. All specimens were fixed with light-polymerizing composite resin (Filtek Z250, 3M ESPE; Seefeld, Germany) on aluminum bases and immersed in an autopolymerizing resin (Technovit 4071, Heraeus-Kulzer; Hanau, Germany).

Provisional restorations of the pulp chamber were made with a temporary filling material (Cavit, 3M ESPE) before cavity preparations.

Tooth Preparation

Thirty-two hours after endodontic treatment, the clinical crowns of all specimens were completely removed 2.5 mm Fig 1 Design of tooth preparation for composite resin overlay.

2.5 mm

3.5 mm 1 mm

above CEJ

1 mm below CEJ

(3)

from the mesial cusps and 3.5 mm from the distal cusps.

The remaining tooth was prepared as follows: rounded 90-degree shoulder, 1.0 mm deep, 1.0 mm above the cementoenamel junction (CEJ) in half the tooth perimeter and 1.0 mm below the CEJ in the other half, using coarse diamond-coated burs (Geneva Prep Set, Intensiv; Viganello, Switzerland) under profuse water-spray cooling (Fig 1).

All dentin surfaces of the pulp chamber and the cavity walls were sealed with a two-step adhesive system (Adhese DC, Ivoclar Vivadent; Schaan, Liechtenstein). Phosphoric acid (Total Etch, Ivoclar Vivadent) was applied to the dentin for 15 s and then rinsed for 30 s. The adhesive system was spread on the dentin with a microbrush without scrubbing.

After a minimum penetration time of 20 s, the resin was air thinned and polymerized (Polylight Steril 2, Castellini;

Castel Maggiore, Italy) for 20 s at a light intensity of 800 mW/cm2. A 0.5-mm-thick composite resin layer (Filtek Z250, 3M ESPE) sealed the canal orifices and the pulp chamber floors in the NFR-NFRC (no foundation restoration, no fiber-reinforced composite resin) and NFR-FRC (no foun- dation restoration, fiber-reinforced composite resin) groups, whereas in the FR-NFRC (foundation restoration, no fiber- reinforced composite resin) and FR-FRC (foundation restor- ation, fiber-reinforced composite resin) groups, a 3-mm- thick foundation restoration was placed using the same light-polymerizing composite resin.

Internal and external cavity finishing lines were finished with a diamond bur (25 μm grain size, no. 3113 NR, Inten- siv) using water cooling under a stereomicroscope. Impres- sions were made using polyether material (Permadyne, 3M ESPE) with a simultaneous mixing technique, according to the manufacturer’s instructions. Provisional restorations were made with a temporary filling material (Fermit N, Ivo- clar Vivadent) and inserted without provisional cement, analogous to the clinical procedure.

Laboratory Manufacturing Process

NFR-NFRC and FR-NFRC groups were restored with compos- ite resin overlays (Adoro, Ivoclar Vivadent) whereas NFR-FRC and FR-FRC groups were restored with fiber-reinforced com- posite resin overlays (Adoro/Vectris Frame, Ivoclar Viva- dent) (Fig 2). Adoro is a microfilled resin composite veneer- ing system containing UDMA as monomer. Vectris Frame consists of several layers of fiber wafers and woven fiber bundles embedded in an organic polymer matrix. Vectris Frame consists of dimethacrylate (44 to 46 wt%), glass fi- bers (49 to 51 wt%), and silicon dioxide (5 to 6 wt%). An impression of the gypsum model with transparent polyvinyl siloxane (Memosil 2, Ivoclar Vivadent) paste was taken for each cavity preparation in the FR-NFRC and FR-FRC groups to form a mold. Four layers of a pre-impregnated sheet of woven-fiber “frame” were placed on the gypsum model and condensed in a deep-drawing, polymerization process using the transparent polyvinyl siloxane. After a cycle of the vac- uum-forming process followed by light polymerization (VS1 unit, Ivoclar Vivadent) for 10 min according to the manufac- turer’s recommendations, excess FRC was removed with a carbide bur to the vertical cavity wall. The FRC base was airborne-particle abraded (Rocatec system, 3M ESPE) with 80-μm particles at 0.25 MPa for 10 s and treated with si- lane (Monobond S, Ivoclar Vivadent, Schaan, Liechten- stein). For all groups, the composite resin (Adoro, Ivoclar Vivadent) was added incrementally. The final polymeriza- tion/tempering was performed in a light-polymerizing unit (Lumamat 100, Ivoclar Vivadent) using light and heat. An additional tempering step at 104°C was performed to maxi- mize the strength and surface quality of the restorations.

Adhesive Procedure

The provisional restorations were removed and the inner surfaces of the teeth previously sealed with bonding were airborne-particle abraded (CoJet system, 3M ESPE) with 30-μm particles at 0.2 MPa for 2 s. Only the enamel Fig 2 Graphic description of different groups with specific arrangement of reinforcement. FR-NFRC: foundation restoration, no fiber-reinforced composite resin; FR-FRC: foundation restoration, fiber-reinforced composite resin; NFR-NFRC: no foundation restoration, no fiber-reinforced composite resin; NFR-FRC: no foundation restoration, fiber-reinforced composite resin.

FR-NFRC FR-FRC NFR-NFRC NFR-FRC

Foundation restoration Fiber-reinforced composite resin

(4)

tests were performed using a universal testing machine (In- stron Model 4301, Instron; Canton, MA, USA) after fatigue loading. A spherical stainless steel punch of 5.0-mm diam- eter was applied perpendicular to and in the middle of the occlusal surface of the specimens. The crosshead speed was 1.0 mm/min and the load was applied until the speci- men fractured. The stress-strain curves were recorded with computer software (Instron 8.2). Three fractured gold-sput- tered (SCD 030, Provac; Balzers, Liechtenstein) specimens for each group were observed at various magnifications with SEM (XL20, Philips; Eindhoven, The Netherlands) to qualita- tively analyze the fracture patterns. Means, medians, and 25th/75th percentiles of the fracture resistance values were calculated. The data for fracture resistance were sub- jected to parametric statistical analyses using two-way ANOVA and Tukey’s test. The level of significance was set at _ = 0.05.

RESULTS

All restorations were in place after completing the fatigue test. Thus, the retention rate was 100% in all groups. The fracture test results are reported in Fig 4.

Two-way ANOVA revealed differences between pairs of means and an interaction between the glass-fiber infra- structure and the presence of a 3.0-mm pulp core made with composite resin (p <0.05). The pairwise comparison of the four groups (post-hoc Tukey’s test) showed statisti- cally significant differences between the pairs: NFR-NFRC/

FR-FRC (p = 0.001), NFR-FRC/FR-FRC (p = 0.001), and FR- NFRC/FR-FRC (p = 0.001). No statistically significant dif- ferences were detected between the pairs: NFR-NFRC/FR- NFRC (p = 0.754), NFR-NFRC/NFR-FRC (p = 0.580), and FR-NFRC/ NFR-FRC (p = 0.899). The mode of failure ob- served was considered instantaneous in all groups, since it was not possible to detect the value of the initial failure in the stress-strain curve, but only the value of the frac- ture load.

Six vertical root fractures and two overlay fractures were recorded on the NFR-NFRC group (Fig 5), whereas in the FR- NFRC group, there were eight vertical root fractures. In the NFR-FRC group, four overlay fractures and four vertical root fractures were found, whereas eight overlay fractures oc- curred in the FR-FRC group (Fig 6). In the FR-FRC and NFR- FRC groups, delaminations at the interface of reinforcing fibers/composite resin veneering material mainly occurred (Fig 7). The fractures started on the occlusal surface at the level of the composite resin.

DISCUSSION

This study compared the fracture strength and the modality of fracture in endodontically treated molars restored with composite resin overlays. Differences between groups in- cluded the presence or absence of reinforcement in the prosthetic restoration and the presence or absence of a margins were etched for 30 s using 37% phosphoric acid

(Total Etch, Ivoclar Vivadent). After rinsing and drying, primer and adhesive (Adhese DC, Ivoclar Vivadent) were ap- plied in a thin layer on the enamel and dentin, according to the manufacturer’s instructions. The inner surfaces of the FRC were airborne-particle abraded at 0.2 MPa for 10 s (CoJet system, 3M ESPE) and two layers of silane coupling agent (Monobond S, Ivoclar Vivadent) were applied on all intaglio surfaces. A layer of the same adhesive system was applied to the treated composite resin surfaces using a mi- crobrush. All enamel, dentin, and composite resin surfaces were luted with a dual-curing composite resin (Variolink II, Ivoclar Vivadent) according to the manufacturer’s protocol.

The luting cement was polymerized (Polylight Steril 2, Cas- tellini) for 60 s each from the cervical, buccal, lingual, and occlusal surfaces (output of light source: 800 mW/cm2).

The margins of the restorations were then finished with 15-μm diamond burs (Composhape, Intensiv) and polished with a composite resin finishing and polishing kit (Compos- ite resin Polishing Kit-Shofu, Shofu; San Marcos, CA, USA) in a low-speed handpiece.

Evaluation

The fatigue test started 2 weeks after storage in water at room temperature (23°C). All specimens were subjected to mechanical loading in a computer-controlled masticator with 1,200,000 cycles of 50 N each using artificial cusps made of stainless steel with hardness similar to natural enamel (Vickers hardness: enamel = from 320 to 325; Actinit stain- less steel = 315). The diameter of the cusps was 5 mm, and they were used to load the occlusal surface of the res- torations in the central fossa (Fig 3). The axial force was exerted at a frequency of 1.7 Hz, following a half-sinusoid curve. In this way, the contacting vectors of all overlays were similar in all specimens because the main load was parallel to the long axis of the abutments. The specimens were kept in water at 37°C during the test. These condi- tions are believed to simulate approximately 5 years of clin- ical service.18 All groups were subjected to fracture tests to measure the fracture strength and fracture patterns. The Fig 3 Specimens during fatigue test.

(5)

foundation restoration. The results obtained showed that fiber reinforcement and foundation restoration can affect the fracture strength and the pattern of fracture; thus, the null hypothesis was rejected.

Although this study has some limitations with respect to its clinical relevance, the mean fracture resistance for all four groups (ranging from 1438 N [SD ± 262 N] to 3000 N [SD ±688 N]) suggests that composite resin restorations can withstand posterior mastication forces, which can

range from 800 to 1000 N.6 Thus, adhesive restorations may represent a valid alternative to the traditional ap- proach.

An important factor may be the direction of the load: in this experiment, axial forces were applied to the middle of the specimens’ occlusal surfaces, simulating a normal oc- clusal situation on a molar. Because fracture resistance depends on the angle of the applied load, future work should examine how nonaxial forces change the outcome Fig 4 Results of ultimate strength load values (N). Different letters

indicate statistically significant differences between groups (p = 0.05, two-way ANOVA and Tukey’s test). NFR-NFRC: no founda- tion restoration, no fiber-reinforced composite resin; NFR-FRC: no foundation restoration, fiber-reinforced composite resin; FR-NFRC:

foundation restoration, no fiber-reinforced composite resin; FR-FRC:

foundation restoration, fiber-reinforced composite resin.

Fig 5 A failure of group NFR-NFRC (no foundation restoration, no fi- ber-reinforced composite resin).

Fig 6 A failure of group FR-FRC (foundation restoration, fiber-reinforced composite resin).

Fig 7 Type of failure (reparable/irreparable). NFR-NFRC: no foundation restoration, no fiber- reinforced composite resin; NFR-FRC: no foundation restoration, fiber-reinforced composite resin; FR-NFRC: foundation restoration, no fiber-reinforced composite resin; FR-FRC: founda- tion restoration, fiber-reinforced composite resin.

NFR-NFRC FR-NFRC NFR-FRC FR-FRC

Restoration fractures/

Restoration delaminations (reparable)

Radicular fractures (irreparable) 8

7 6 5 4 3 2 1 0 NFR-NFRC FR-NFRC NFR-FRC FR-FRC 4500

4000

3500

3000

2500

2000

1500

1000

500

0

Group

Newton

A A A

B

(6)

compared to that in this study.26 Moreover, the lack of thermocycling simultaneously performed with occlusal load- ing represents another limitation of this study. In fact, it has been suggested that thermocycling may further stress and weaken the adhesive bond, decreasing fracture strength and increasing microleakage.11

The different failure modes of the groups suggest that the absence of a foundation restoration did not predis- pose to root fracture in groups restored with composite resin overlays without reinforcement with glass fibers (NFR-NFRC and FR-NFRC groups), whereas it significantly reduces the incidence of this kind of fracture in groups restored with composite resin overlays with glass fiber re- inforcement (NFR-FRC and FR-FRC groups). The NFR-NFRC group exhibited six vertical root fractures and two overlay fractures; in the FR-NFRC group, eight vertical root frac- tures were observed; four overlay fractures and four verti- cal root fractures were observed in the NFR-FRC group, and in the FR-FRC group, eight overlay fractures were re- corded. These results may be due to the disposition and position of the glass fibers in the specimens with a foun- dation restoration, which permits a coronal deflection of the vertical fracture line. Position and fiber orientation in- fluence the loads at initial and final failure.10,17 The pos- itioning of fibers occlusal to the CEJ, as in the FR-FRC group, seemed to be more effective in avoiding irreparable root fracture. The fracture resistance of specimens with- out a foundation restoration (the mean fracture strength of the NFR-FRC group was 1438 N) was not significantly dif- ferent from that of the groups restored with composite resin overlays without glass-fiber reinforcement (the NFR- NFRC group fractured at a mean of 1677 N, the FR-NFRC group at a mean of 1498 N), and differences were seen in the mode of failure. The NFR-FRC group, despite having the lowest fracture strength, showed fewer root fractures than did the NFR-NFRC or FR-NFRC group. In contrast, the FR-FRC group showed the highest fracture strength (3000 N). In addition, the FR-FRC group only resulted in reparable

fractures. The distance between the fibers and crack initi- ation may explain this different behavior. In the FR-FRC group, which had a foundation restoration, the distance between the fibers and the occlusal surface, where the crack began, is reduced; for this reason, the fibers can withstand tensile stress and stop crack propagation (Fig 8). In the NFR-FRC group, the distance and the amount of composite resin between the fibers and the occlusal sur- face were greater, so the fibers could not prevent fracture propagation. NFR-FRC and FR-FRC groups showed a more favorable manner of failure compared with the groups re- stored with composite resin overlays without glass-fiber reinforcement. This may be explained by the glass-fiber arrangement, which results in greater fracture resistance and better transmission of the stresses. These results confirm the ability of glass-fiber reinforcement to deflect a crack, preventing unfavorable propagation in a cervical di- rection, and facilitating re-restoration in the case of frac- ture. Nevertheless, it should be emphasized that the re- sults obtained in this study may have been influenced by the lack of a simulated periodontal ligament. In fact, Soares et al32 found that this factor can significantly af- fect the fracture mode of bovine teeth in vitro.

Magne et al20 found that vital molars with a compro- mised cusp can be reinforced using a composite resin onlay, but that a polyethylene fiber patch did not affect the pattern of fracture. Thus, in vivo, the presence of fiber re- inforcement does not seem to be essential in small restor- ations carried out on vital teeth. A study by Brunton et al4 showed that specimens with FRC produced fewer fractures of the tooth substrate than specimens without FRC. In fact, glass fibers are known to be able to withstand tensile stress and to stop crack propagation in composite resin material.15,19,29,39 The results of this study, however, are consistent with those of Dere et al.7 These authors demon- strated that fiber-reinforced overlays, besides achieving higher fracture toughness values, induced more favorable patterns of fracture in vitro. Fibers may produce a sort of ferrule effect, surrounding the remaining gingival tooth structure. These results suggest that the incorporation of glass fibers, in association with a foundation restoration, can increase the load-bearing capacity of molars with cusp- replacing restorations.

CONCLUSIONS

Within the limitations of this in vitro study, the results dem- onstrated that the use of composite resin overlays repre- sents a conservative approach to rehabilitation of endodon- tically treated teeth. The fracture strength of all composite resin overlays was higher than the likely bite forces. The incorporation of glass fibers increased fracture resistance and had a positive effect on the failure mode and thus on the re-restorability in case of fracture. The arrangement of fiber reinforcement occlusal to the CEJ enabled an increase in the fracture strength and a reduction in the risk of root fracture.

Fig 8 SEM image of a specimen from the FR-FRC group (founda- tion restoration, fiber-reinforced composite resin).

The fracture is deflected by fibers without affecting

the root

(7)

REFERENCES

1. Assif D, Gorfil C. Biomechanical considerations in restoring endodonti- cally treated teeth. J Prosthet Dent 1994;71:565-567.

2. Baratieri LN, De Andrada MA, Arcari GM, Ritter AV. Influence of post placement in the fracture resistance of endodontically treated incisors ve- neered with direct composite resin. J Prosthet Dent 2000;84:180-184.

3. Barkhordar RA, Radke R, Abbasi J. Effect of metal collars on resistance of endodontically treated teeth to root fracture. J Prosthet Dent 1989;61:

676-678.

4. Brunton PA, Cattel P, Burke FJ, Wilson NHF. Fracture resistance of teeth restored with onlays of three contemporary tooth-colored resin-bonded re- storative materials. J Prosthet Dent 1999;82:167-171.

5. Creugers NH, Mentink AG, Fokkinga WA, Kreulen CM. 5-year follow-up of a prospective clinical study on various types of core restorations. Int J Prosthodont 2005;18:34-39.

6. De Boever JA, Mc Call VD, Golden S, Ash MM. Functional occlusal forces:

an investigation by telemetry. J Prosthet Dent 1978;40:326-333.

7. Dere M, Özcan M, Göhring TN. Marginal quality and fracture strength of root-canal treated mandibular molars with overlay restorations after ther- mocycling and mechanical loading. J Adhes Dent 2010;12:287-294.

8. Dietschi D, Duc O, Krejci I, Sadan A. Biomechanical considerations for the restoration of endodontically treated teeth: A systematic review of the literature, Part II (Evaluation of fatigue behavior, interfaces, and in vivo studies). Quintessence Int 2008;39:117-129.

9. Dietschi D, Duc O, Krejci I, Sadan A. Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, Part 1. Composition and micro- and macrostructure alterations.

Quintessence Int 2007;38:733-43.

10. Dyer SR, Lassila LVJ, Jokinen M, Vallittu PK. Effect of fiber position and orientation on fracture load of fiber-reinforced composite resins. Dent Mater 2004;20:947-955.

11. Eakle WS. Effect of thermal cycling on fracture strength and microleakage in tooth restored with a bonded composite resin resin. Dent Mater 1986;

2:114-117.

12. Edelhoff D, Sorensen JA. Tooth structure removal associated with various preparation designs for posterior teeth. Int J Periodontics Restorative Dent 2002;22:241-249.

13. Fokkinga WA, Le Bell AM, Kreulen CM, Lassila LV, Vallittu PK, Creugers NH. Ex vivo fracture resistance of direct resin composite resin complete crowns with and without posts on maxillary premolars. Int Endod J 2005;38:230-237.

14. Ichim I, Kuzmnaovic DV, Love RM. A finite element analysis of ferrule de- sign on restoration resistance and distribution of stress within a root. Int Endod J 2006;39:443-452.

15. Isaac DH. Engineering aspects of fiber reinforced composite resins. In:

Vallittu PK (ed). The first symposium on fiber reinforced plastics in den- tistry. Turku: University of Turku, 1999.

16. Isidor F, Brondum K, Ravnholt G. The influence of post length and crown ferrule length on the resistance to cyclic loading of bovine teeth with pre- fabricated titanium posts. Int J Prosthodont 1999;12:78-82.

17. Karbhari VM, Strassler H. Effect of fiber architecture on flexural charac- teristics and fracture of fiber-reinforced composite resins. Dent Mater 2007;23:960-968.

18. Krejci I, Reich T, Lutz F, Albertson M. In-vitro-Testverfahren zur Evaluation dentaler Restaurationssysteme. Schweiz Monatsschr Zahnmed 1990;

100:8-14.

19. Lassilla LVJ, Nohrstrom T, Vallittu PK. The influence of short-term water storage on the flexural properties of unidirectional glass fiber-reinforced composite resins. Biomaterials 2002; 23:2221-2229.

20. Magne P, Boff LL, Oderich E, Cardoso AC. Computer-aided-design/com- puter-assisted-manufactured adhesive restoration of molars with a compro- mised cusp: effect of fiber-reinforced immediate dentin sealing and cusp overlap on fatigue strength. J Esthet Restor Dent 2012; 24:135-147.

21. Manhart J, Chen HY, Hamm G, Hickel R. Buonocuore Memorial Lecture.

Review of the clinical survival of direct and indirect restorations in poster- ior teeth of the permanent dentition. Oper Dent 2004;29:481-508.

22. Oliveira FC, Denehy GE, Boyer DB. Fracture resistance of endodontically prepared teeth using various restorative materials. J Am Dent Assoc 1987;115:57-60.

23. Oskoee PA, Ajami AA, Navimipour EJ, Oskoee SS, Sadjadi J. The effect of three composite resin fiber insertion techniques on fracture resistance of root-filled teeth. J Endod 2009;35:413-416.

24. Peters MC, McLean ME. Minimally invasive operative care. I: Minimal in- tervention and concepts for minimally invasive cavity preparations.

J Adhes Dent 2001;3:7-16.

25. Peters MC, McLean ME. Minimally invasive operative care. II: Contempo- rary techniques and materials: an overview. J Adhes Dent 2001;3:17-31.

26. Plasmans PJ, Visseren LG, Vrijhoef MM, Kayser AF. In vitro comparison of dowel and core techniques for endodontically treated molars. J Endod 1986;12:382-387.

27. Reeh SE, Messer HH, Douglas WH. Reduction in tooth stiffness as a result of endodontic and restorative procedures. J Endod 1989;15:

512-516.

28. Salameh Z, Sorrentino R, Ounsi HF, Goracci C, Tashkandi E, Tay FR, Ferrari M. Effect of different all-ceramic crown system on fracture resis- tance and failure pattern of endodontically treated maxillary premolars re- stored with and without glass fiber posts. J Endod 2007;33:848-51.

29. Scheirs J. Failure of fiber reinforced composite resins. In: Scheirs J (ed).

Compositional and failure analysis of polymers. A practical approach.

Chicester: Wiley, 2000:304-362.

30. Scotti N, Coero Borga FA, Alovisi M , Rota R, Pasqualini D, Berutti E. Is fracture resistance of endodontically treated mandibular molars restored with indirect onlay composite resin restorations influenced by fibre post insertion? J Dent 2012;40:814-820.

31. Shugars DA, Hayden WJ, Crall JJ, Scurria MS. Variation in the use of crowns and their alternatives. J Dent Educ 1997;61:22-28.

32. Soares CJ, Pizi EC, Fonseca RB, Martins LR. Influence of root embedment material and periodontal ligament simulation on fracture resistance tests. Braz Oral Res 2005;19:11-16.

33. Sorensen JA, Engelman MJ. Ferrule design and fracture resistance of end- odontically treated teeth. J Prosthet Dent 1990;63:529-535.

34. Sorensen JA, Martinoff JT. Intracoronal reinforcement and coronal cover- age: a study of endodontically treated teeth. J Prosthet Dent 1984;51:

780-784.

35. Stankiewicz NR, Wilson PR. The ferrule effect: a literature review. Int Endod J 2002;35:572-581.

36. Stockton L, Lavelle CLB, Suzuki M. Are posts mandatory for the restor- ation of endodontically treated teeth? Dent Traumatol 1998;14:59-63.

37. Tam LE, Pilliar RM. Fracture toughness of dentin/resin-composite resin adhesive interfaces. J Dent Res 1993;72:953-9.

38. Valdivia AD, Raposo LH, Simamoto-Júnior PC, Novais VR, Soares CJ. The effect of fiber post presence and restorative technique on the biomech- anical behavior of endodontically treated maxillary incisors: An in vitro study. J Prosthet Dent 2012;108:147-157.

39. Vallittu PK. Flexural properties of acrylic polymers reinforced with unidirec- tional and woven glass fibers. J Prosthet Dent 1999;81:318-326.

40. Wagnild GW, Mueller KI. Restoration of endodontically treated teeth, St.

Louis: Mosby, 2002:769-775.

Clinical relevance: The use of fiber-reinforced overlays is a possible alternative to prosthetic crowns in end- odontically treated teeth and can prevent irreparable root fractures.

Références

Documents relatifs

The first one provides a view of a Twitter 4 account (last Tweets of the considered account and the last public Tweets). The second one, an Event Visualiser,

The macromecanical approach study of the strength to the composite material failure consists of the search of a criterion allowing establishing the final

While some studies observed more risk of failure, mainly due to fracture of the marginal ridge [7,10,11,14], for tunnel or occlusal fossa restorations compared to those

The groups were as follows: “Normal”: direct resin composite; “Ring”: glass fiber- reinforced strip (Dentapreg) wrapped around buccal and lingual walls followed by direct

Abstract : This study puts in evidence the effect of the change of the arrangement of the reinforcement(unidirectional, woven fabric and mat) on the rupture of E-glass/epoxy

The objective of the current study was to gain a better understanding of mechanical and dynamic mechanical properties of hybrid composite laminate reinforced with glass woven

The objective of the current study was to gain a better understanding of mechanical and dynamic mechanical properties of hybrid composite laminate reinforced

The second corollary concerns the group G(X ) which is a finite transitive permutation group for any thin complete code (thus the fact that such a group is cyclic implies that it