• Aucun résultat trouvé

INDUSTRIAL BASIC/RT-11,

N/A
N/A
Protected

Academic year: 2022

Partager "INDUSTRIAL BASIC/RT-11, "

Copied!
2
0
0

Texte intégral

(1)

momoomo

Software Product Description

PRODUCT NAME:

INDUSTRIAL BASIC/RT-11,

Version 1 SPD 15.14.1

DESCRIPTION:

Industrial BASIC/RT-11 is a single-user, interactive programming language designed for the industrial computer user. It operates under the RT-11 operating system. Like standard Dartmouth BASIC, it is simple to learn; it uses English-like statements and familiar mathematical notations to describe a procedure. In- dustrial BASIC/RT -11 provides real-time extensions to enable the control and monitoring of analog and digital input/output. Interrupt processing, alarm, and timing functions are also included.

Specific features include:

• Sequential and virtual memory file support for RT- 11 mass storage devices.

• Chaining and overlay support to accommodate large programs.

• Extensive support for the Industrial Control Subsys- tem (ICS 11) including A/D converters, 0/ A convert- ers, digital I/O, counter and interrupt modules.

• Support for the AR11 Analog Real-Time Subsys- tem, DR11, and DRS 11 /DSS11 Digital I/O Subsys- tems.

Industrial BASIC/RT-11 is an incremental compiler which provides access to RT -11's file structure. All files are stored contiguously for random access and elimination of the need for linkages across empty blocks. The file structure implemented under Industri- al BASIC/RT-11 includes provisions for up to seven sequential files and seven virtual arrays, all of which can be open simultaneously. Virtual arrays accept da- ta in a manner that appears to the source program to be memory resident.

The Industrial Control Subsystem (ICS 11) is fully sup- ported by Industrial BASIC/RT-11. All ICS commands are initiated by CALL statements to input/output, time-based, or interrupt processing routines.

MINIMUM HARDWARE REQUIRED:

Any valid RT -11, Version 2S or 2C configuration with at least 16K words of memory and either RX11 floppy disk or RK05 cartridge disk for the load device.

OPTIONAL HARDWARE:

DR11-K General Device Interface AR11 Analog Real-Time System DRS11 Digital Output Subsystem DSS11 Digital Input Subsystem

ICS11 Industrial Control Subsystem (local)

October 1977

IDC-IA Isolated DC Sense IDC-IS Isolated DC Interrupt IDC-IC I/O Counter

IDC-ID Non-isolated DC Sense IDC-IE Non-isolated DC Interrupt IAC-IA Isolated AC Sense lAC-IS Isolated AC Interrupt IDC-OA DC Flip Flop Driver IDC-OB DC Single Shot Driver IRL-OA Latching Relay Output IRL-OB Flip-Flop Relay Output IDA-OB 4-Channel 0/ A Converter IAD-IA a-Channel A/D Converter

IMX-IA 16-Channel Multiplexer for IAD-IA PREREQUISITE SOFTWARE:

RT-11 Operating System, Version 28 or 2C only.

OPTIONAL SOFTWARE:

None

TRAINING CREDITS:

None

SUPPORT CATEGORY:

C - Software Support will be provided as listed in the Software Support Categories Addendum to this SPD.

UPDATE POLICY:

Software Updates, if any, released by DIGITAL during the one (1) year period following installation, will be provided to the customer for a media charge. After the first year, updates, if any, will be made available according to then prevailing DIGITAL policies.

ORDERING INFORMATION:

This software Is furnished under a license for use on a single CPU and can be copied and modified (with inclusion of DIGITAL's copyright notice) only for use on such CPU, except as may otherwise be provided in writing by DIGITAL.

Source and/or listing options are only available after a source license agreement is in effect.

AE-C871 B-TC

(2)

INDUSTRIAL BASIC/RT-11, Version 1

The following key (E, Y) represents the distribution media for the product and must be specified at the end of the "Q" number, i.e., QJ2BO-CE = binaries on RK05 Disk.

E

=

RK05 Disk Y

=

Floppy Disk Standard Options

QJ280 -C- Single-use license, binaries, documen- tation, no support services (media: E,

Y)

ADDITIONAL SERVICES:

None

015.14.1

SPD 15.14.1 -2-

Références

Documents relatifs

Cours de Toxicologie Clinique 2A Philippe Berny 2012.. Cours de Toxicologie Clinique 2A Philippe Berny

La forme étroite et allongée de ces pinces leur permet d’effectuer des mesures dans des torons de câbles ou des endroits étriqués comme les câblages de tableaux,

[r]

The proposed scaling function can be used in the design of isolated dc-dc converters using 25 mm × 25 mm × 100 mm I- cores or similar, based on the core material datasheet and

(En anglais : Racine se dit Root, Moyenne se dit Mean et Carré se dit Square) d’où le sigle « RMS » pour les appareils qui mesurent les valeurs efficaces. Cette relation doit

3 Si la charge est constituée d'une résistance en série avec une inductance (charge RL) l'inductance L s'oppose aux variations du courant. L'ondulation de autour de sa

Les intervalles de commande de ces deux thyristors doivent donc se chevaucher (voir le graphe des intervalles de commande).. La loi de conservation de l’énergie précise que

Il s’agirait d’un sch´ ema-bloc avec un bloc pour le redresseur (deux entr´ ees et deux sorties), un bloc pour la charge ´ electrique (une entr´ ee et une sortie) et un g´