First International Conference on Electrical Energy and Systems ICEES'13 2013

Modelling, Faults Detection and Diagnosis of Squirrel-Cage Self Excited Induction Generator

for Isolated Wind Energy Conversion System

Issam Attoui, Amar Omeiri

Abstract : The condition monitoring of the Squirrel-cage Self-Excited Induction Generator (SEIG). can significantly reduce the costs of maintenance, prevent the unscheduled downtimes and make the best maintenance decisions for isolated Wind Energy Conversion Systems (WECS). On the other hand, growing attention has been paid to fractional calculus theory in practical control field for many industrial applications. In this paper, an on-line diagnostic procedure for stator and rotor faults in the squirrel SEIG of isolated wind energy conversion system is presented. This diagnostic procedure is based on stator current analysis by FFT. A generalized model of the squirrel-cage SEIG is developed to simulate both the rotor and stator faults taking iron loss, cross flux saturation into account. Additionally, a new control strategy is proposed for the fixed operation of the wind turbine, based on fractional PI? controllers.

Keywords : Issam Attoui, Amar Omeiri

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

The carried out experiments on a 1.1-kW induction generator based test bench have proved that a technique based on variance and energy analysis of wavelet

In the case of wind turbine condition monitoring, a number of published work are based on the following hypothesis: It is possible to detect wind turbine drive train faults

3) Teager energy operator: The Teager energy operator (TEO) allows to track the IF and the IA of a modulated signal without computing the analytic signal [26].. The ESA

In the case of wind turbine condition monitoring, a number of published works are based on the following hypothesis: It is possible to detect wind turbine drive train faults

In this paper, the Direct Power Control (DPC) is considered, so, the converter switching states are selected by a switching table based on the instantaneous errors between the

Keywords: wind energy conversion systems, induction generator, signal possessing, fault severity factor, faults classification, fault detection and diagnosis.. Received 4 November

The FOC ensures the stability of the nonlinear system in both healthy and faulty conditions.Furthermore, in order to detect the stator and rotor faults in the squirrel-cage

The fuzzy observer used in this paper is based on the combination of the TS fuzzy model and the idea of PDC.The effectiveness of the proposed methodology is