• Aucun résultat trouvé

Real-Time Switches Fault Diagnosis for VoltageSource Inverter Driven Induction Motor Drive

N/A
N/A
Protected

Academic year: 2021

Partager "Real-Time Switches Fault Diagnosis for VoltageSource Inverter Driven Induction Motor Drive"

Copied!
1
0
0

Texte intégral

(1)

International Journal of Electrical and Electronic Engineering & Telecommunications

Volume 8, Issue 2, 2019, Pages 103-107

Real-Time Switches Fault Diagnosis for Voltage Source Inverter Driven Induction Motor Drive

H. MERABET, T. BAHI, K. Bedoud, D. DRICI

Abstract: Induction machine is the frequently used for electrical drive applications in almost many industrial processes due to its simple and robust construction. Speed control of induction machine is required depending on the type of application. Speed of the induction motor can be varied by varying frequency or by variation of the terminal voltage. Variable voltage can be fed to induction machine using the voltage source inverter which is found efficient technique of controlling induction motor drive. The potential faults that occur in inverter are the open and short circuit switch fault. The cost of this schedule can be high, and this justifies the development of fault diagnostic methods. In this paper we present a reliable strategy for diagnosis and detection of open and short circuit switch faults in plush width modulation of voltage source inverter (PWM-VSI) using the fuzzy logic approach. The principle of the proposed approach is based on the acquisition of stator currents, to calculate the average absolute values of currents (AAVC), which allows the real-time detection and localization of inverter IGBT open or short-circuit faults using just the motor phase currents. A model of the system is built using MATLAB/SIMULINK. Simulation results are presented showing the monitoring approach performance under distinct operating conditions.

Keywords : open circuit fault, short circuit fault, Fuzzy logic, modeling, simulation

Centre de Recherche en Technologies Industrielles - CRTI - www.crti.dz

Powered by TCPDF (www.tcpdf.org)

Références

Documents relatifs

PWM-VSI power switches open circuit/misfiring detection and diagnosis, the proposed fuzzy approach will be based on the output inverter current pattern in the Concordia

Parameter variations are usually tracked by adaptive mechanisms using additional sensors (stator temperature for example) or specific algorithms based on weak assumptions like

Experimental results obtained for a stator fault situation in nominal operation with a SF = 60 % in the phase A (A) Stator currents of the machine (B) Experimental αβ-vector

Comparing with conventional fault diagnosis methods of inverter fed induction machine, in our work we are presented a reliable strategy for monitoring, detection and localization

In this paper, we propose a method for the eccentricity diagnosis fault based on the stator current analysis during the start-up using this wavelet method enables faults

Furthermore, analysis of the stator current was conducted in healthy cases and in the presence of defects, the second method of fault detection in this work,is based on

On the other hand, growing attention has been paid to fractional calculus for many industrial an on-line diagnostic procedure for stator and rotor faults in

Figure 9 shows instantaneous amplitude of two stator currents; one healthy (discontinued line) and one with fault (solid line). It is clear that the