• Aucun résultat trouvé

G4DARI: Geant4/GATE based Monte Carlo simulation interface for dosimetry calculation in radiotherapy.

N/A
N/A
Protected

Academic year: 2021

Partager "G4DARI: Geant4/GATE based Monte Carlo simulation interface for dosimetry calculation in radiotherapy."

Copied!
1
0
0

Texte intégral

(1)

1

Publications Internationales du labo Signaux et systèmes Auteurs:

Slimani F. AA, Hamdi M, Bentourkia M

Titre du l’article / ou bien communication:

G4DARI: Geant4/GATE based Monte Carlo simulation interface for dosimetry calculation in

radiotherapy.

Date de publication : 28 avril 2018

Nom de journal :

Computerized Medical Imaging and Graphics

Numéro de série / ou bien collection:

67

Numéro de volume : Identification :

https://doi.org/10.1016/j.compmedimag.2018.04.008

Type : Journal Langue de l’article : Anglais Mot clé :

Dosimetry; External radiotherapy; Geant4; Monte Carlo simulation; Particle interaction Résumé :

Monte Carlo (MC) simulation is widely recognized as an important technique to study the physics of particle interactions in nuclear medicine and radiation therapy. There are different codes dedicated to dosimetry applications and widely used today in research or in clinical application, such as MCNP, EGSnrc and Geant4. However, such codes made the physics easier but the programming remains a tedious task even for physicists familiar with computer programming. In this paper we report the development of a new interface GEANT4 Dose And Radiation Interactions (G4DARI) based on GEANT4 for absorbed dose calculation and for particle tracking in humans, small animals and complex phantoms. The calculation of the absorbed dose is performed based on 3D CT human or animal images in DICOM format, from images of phantoms or from solid volumes which can be made from any pure or composite material to be specified by its molecular formula. G4DARI offers menus to the user and tabs to be filled with values or chemical formulas. The interface is described and as application, we show results obtained in a lung tumor in a digital mouse irradiated with seven energy beams, and in a patient with glioblastoma irradiated with five photon beams. In conclusion, G4DARI can be easily used by any researcher without the need to be familiar with computer programming, and it will be freely available as an application package.

Références

Documents relatifs

The results of two application examples are presented : the design optimization of a liquid Xe µPET camera dedicated to small animal imaging as well as the evaluation of the effect of

Count rate curves taking into account random coincidences and dead-time are shown for a dual-crystal set-up and for a small-animal PET scanner design.. Simulated resolution curves

Two alternative approaches are used to calculate the cross sections. The first one [21] takes into account the five excitation levels of the water molecule described. It consists

GATE complète les grandes potentialités offertes par le code Geant4 grâce à des modules spécifiques permettant d’élaborer des simulations réalistes : simulation du temps

It provides a collection of classes representing typical accelerator com- ponents, a collection of physics processes for fast tracking, procedures of “on the fly“ geometry

Verification of a Monte carlo dose calculation engine in proton minibeam radiotherapy in a passive scattering beamline for preclinical trials.. British Journal of Radiology,

Following the different steps presented in Figure 1, the GATE toolkit was used to compute the mean percentage depth dose distributions in the breast volume with a 1 mm

The main interest of a slower and detailed Monte Carlo simulation such as GATE/GEANT4 is its versatility: it can be used as a reference Monte Carlo code for vali- dation purposes,