Framework for Ultrasonography-based Augmented Reality in Robotic Surgery: Application to Transoral Surgery and Gastrointestinal Surgery

N/A
N/A
Protected

Academic year: 2021

Partager "Framework for Ultrasonography-based Augmented Reality in Robotic Surgery: Application to Transoral Surgery and Gastrointestinal Surgery"

Copied!
162
0
0

Texte intégral

Loading

Figure

Figure 1.3 – The console (left) and three robotic arms respectively holding a surgical grasper, a cutting/ablating instrument and a 3D endoscopic camera (right) of the da Vinci ® surgical system used in transoral robotic surgery.
Figure 1.5 – Robot-assisted laparoscopic colorectal surgery using a da Vinci ® surgical plat- plat-form.
Figure 1.6 – The location of a supra-anal tumor in a rectum. Figure reproduced from Anorectum-en.svg (author: National Institute of Diabetes and Digestive and Kidney  Dis-eases (NIDDK)), used under Attribution-ShareAlike 4.0 International (CC BY-SA 4.0).
Figure 1.7 – Resection of supra-anal tumor and ultra-low colorectal anastomosis.
+7

Références

Documents relatifs

North-South translocal ties are not the only ones involved here however as the municipality has also studied and learned from a community project in Cotonou (Benin). According to the

Quevedo renuncia a la alternancia entre cordura y locura («un entreverado loco, lleno de lúcidos intervalos», ii, 18), y suprime el viaje final hacia la razón antes de morir.

This paper proposes an augmented reality framework that is able to estimate, in real-time, the position relevant of internal structures of the liver (vessels and tumors) taking

The use of a biomechanical model to propagate the surface motion to the internal structures not visible on the endo- scopic images, , such as tumors, requires a stable

Compared to current techniques, which are limited to a rigid registration of the pre-operative liver anatomy with the intra-operative image, we propose a real-time,