• Aucun résultat trouvé

Reproducibility of dynamometric and non-dynamometric trunk extensor muscle tests in patients with chronic low back pain

N/A
N/A
Protected

Academic year: 2021

Partager "Reproducibility of dynamometric and non-dynamometric trunk extensor muscle tests in patients with chronic low back pain"

Copied!
1
0
0

Texte intégral

(1)

M. Vanderthommen, S. Grosdent, J.M. Crielaard, C. Demoulin

Department of Motricity Sciences (University of Liege) and Hospital Center University of Liege, Belgium

mvanderthommen@ulg.ac.be — adepaifve@ulg.ac.be

Reproducibility appeared satisfactory for the strength test, moderate for the

Sorensen test and low for the dynamometric endurance test in patients with

moderate CLBP.

IV. CONCLUSION

I. BACKGROUND AND AIMS

Literature describes several dynamometric and non-dynamometric tests to assess trunk extensor muscle performances. In patients with chronic low back pain (CLBP), reproducibility of such assessments remains understudied. The purpose of this study was to compare reproducibility of two dynamometric tests and of the widely used Sorensen test.

44 patients (22 men, 22 women; age range: 30-60 years) with CLBP (mean Roland-Morris disability scores reaching 6 ± 3.4) were randomized into two groups attending two assessment sessions. Group 1 (12 men and 12 women) underwent two tests (i.e. a maximal strength test

(Figure 1) and a static endurance test requiring to

maintain as long as possible a torque of 50 percent of maximal strength previously determined (Figure 2)) performed on a specific trunk extensor dynamometer (David Back). Group 2 (10 men and 10 women) was submitted to the non-dynamometric Sorensen test (lifting the upper trunk and maintaining the horizontal position) (Figure 3).

Mean torques reached 2.67 ± 0.63 Nm/Kg (women) and 3.66 ± 0.75 Nm/Kg (men) for the strength test. Mean maintaining times were 83 ± 34 s for the endurance test and 99 ± 28 s for the Sorensen test.

Reproducibility of dynamometric and

non-dynamometric trunk extensor

muscle tests in patients with chronic

low back pain

II. METHODS

III. RESULTS

The Table I presents coefficient of variations (CV) and limits of agreement (LOA) related

to the intra-session and inter-session reproducibility.

Table I

For both groups, tests were performed twice (spaced by 15 minutes) during the first session (intra-session reproducibility) and once during the second session

(inter-session reproducibility) happening 2 to 7 days later. Figure 3:

Sorensen test

Figure 2: static endurance test

Figure 1: Maximal strength test

CV 95% LOA CV 95% LOA

Dynamometric strength test (n = 24) 7.8% -43/59 N.m-1 5.6% -34/42 N.m-1

Dynamometric endurance test (n = 24) 18.7% -45/39 seconds 24.8% -60/52 seconds

Sorensen test (n = 20) 14.8% -48/24 seconds 17.2% -40/14 seconds

Références

Documents relatifs

Conventional visual identification and proposed automated methods of time point limits detection of relaxation phase were compared on experimental data using criteria of accuracy

These recent findings could be summarized by stating that research has to date (1) failed to identify any combination of well- defined psychosocial risk factors, which would

To prospectively study the prevalence of psychological, social, musculoskeletal and somatoform disorders in patients presenting with chronic non-specific LBP to general practitioners,

It, then, (1) automatically extracts the information required for test generation from the model including the names, data types and data ranges of the input and output variables of

We devise a test for synthetic consciousness based on neural prosthetics, and explain how this test can supplement ACT.. We then identify two other kinds of

The most important findings in this study there were as follows. 1) There was no significant difference in the onset times of the gluteal muscles between the LBP and control group

Our working hypotheses were that patients would cluster into different behavioral profiles based on characteristics such as anxiety, depression, false beliefs, and coping methods

The second manuscript of this research thesis involved a systematic review and meta-analysis following PRISMA guidelines on what is already known about global appropriateness of