• Aucun résultat trouvé

Axillary temperature measurement: a less stressful alternative for hospitalised cats?

N/A
N/A
Protected

Academic year: 2021

Partager "Axillary temperature measurement: a less stressful alternative for hospitalised cats?"

Copied!
1
0
0

Texte intégral

(1)

Axillary temperature measurement: a less stressful alternative for hospitalised cats? 1. M. Girod, DVM1,

2. M. Vandenheede, DVM, PhD, Dip ECAWBM (WSEL)1, 3. F. Farnir, PhD, Professor of Biostatistics2 and

4. K. Gommeren, DVM, Dip ECVIM-CA1 + Author Affiliations

1. 1Department of Small Animal Clinical Science, University of Liège, Quartier Vallée 2, Avenue de Cureghem, 3, B44, Liège 4000, Belgium

2. 2Department of Animal Production, University of Liège, Quartier Vallée 2, Avenue de Cureghem, 3, Liège 4000, Belgium

1. E-mail for correspondence: maudgirod@msn.com Abstract

Rectal temperature measurement (RTM) can promote stress and defensive behaviour in hospitalised cats. The aim of this study was to assess if axillary temperature measurement (ATM) could be a reliable and less stressful alternative for these animals. In this prospective study, paired rectal and axillary temperatures were measured in 42 cats, either by a veterinarian or a student. To assess the impact of these procedures on the cat's stress state, their heart rate was checked and a cat stress score (CSS) was defined and graded from 1 (relaxed) to 5 (terrified). A moderate correlation was found between RTM and ATM (r=0.52; P<0.0001). RTM was on average 0.9°C (1.6°F) higher than ATM (P<0.0001), although a wide variation was found in the difference between these two measurements (−2.1°C to 3.6°C (−3.8°F to 6.5°F)). ATM failed to identify hypothermia in 25 per cent of the cases and hyperthermia in 19 per cent of the cases but may be considered less stressful than RTM. Indeed, RTM induced a mildly greater increase in heart rate (+6 bpm; P=0.01) and in CSS (+0.2; P=0.001) than ATM. The results were not affected by operator type. In conclusion, RTM should remain the standard method to obtain accurate temperatures in cats.

 Accepted January 8, 2016.

Références

Documents relatifs

In Chapter 5, we use the adap- tively damped Picard iterations and a restricted unigrid method to solve nonlinear diffusion problems and ensure the positivity of approximate

It is only for very shallow trees ( max_depth=1 or 2 ) and high relevance that X 2 is identified with higher confidence than in ETs... Im- portance scores are normalized by the sum

With persisting errors, there is just one optimization problem at the start of the first period.. in α i ), but not at the correct level, as individuals make a mistake when

Smart Point Clouds for information modelling: application in Cultural Heritage | 2 Nov.. What is

Sensitivity experiments with warmer SSCs based on the CMIP5 biases reveal integrated SMB anomalies ( + 5 % to + 13 %) over the present climate (1979–2015) in the lower range of the

• L’avis est la résultante d’un processus de construction collective.. • La qualité de l’avis final dépend

Les patients étaient divisés en deux cohortes : un bras non chirurgical, comparant le TAVR (approche transfémorale) au traitement médical optimal, plus éventuelle valvuloplastie