Preoperative planning of THA: Must this essential part of the procedure be

necessarily performed by the orthopaedic surgeon?

Is the templating influenced by the implant design?

A prospective study about 200 THA using 3 different stem designs.

Thirion T, Georis P, Kurth W, Joris O, Szecel Z, Gillet P.

Orthopaedic Surgery, University Hospital Sart-Tilman, Liège, Belgium

Background

Templating in THA is essential for accurately predicting the optimal size of the implants required. Preoperative planning decreases the risk of implant undersizing or oversizing, facilitates intraoperative orientation and also reduces the risk of potential complications.

To our knowledge, it is unclear if planning is influenced by the background of planner and/or the implant design.

Objectives

The first objective of the present study was to check the reproducibility of our preoperative digital 2D templating and to compare the accuracy between three independent planners with different clinical experiences : orthopedic surgeon (OS), orthopedic resident (OR) and data manager (DM).

The other aim of this study was to compare the effect of three different femoral component designs on preoperative planning accuracy.

Study design and Methods

One hundred uncemented Corail® stems (KA, KHO, KLA) associated

with Pinnacle® cups, 59 CLS® (125°, 135°, 145°) and 41 cemented MS-30®

(STD, LAT) stems associated with Allofit® cups were included in the

study.

The bearing surfaces were ceramic/ceramic or ceramic/crosslinked polyethylene.

The software used for templating was IMPAX-Orthopaedic-Tools®. A

metallic ball was used for calibration.

All the anteroposterior pelvis radiographs were planned by three participants (OS, OR, DM).

Results

We systematically collected the planned size measurements as well as the variation by 1, 2 or more sizes of implanted prostheses.

Regarding Pinnacle®/Corail® implants, at +/- 1 size, we did not find any

significant difference between the participants (OS, OR and DM) with respectively 94%, 96% and 93% concordance for the cup, 88%, 90% and 90% for the stem.

Regarding Allofit® cups, at +/- 1 size, we did not find any significant

difference between the planners (OS, OR and DM) with respectively 85%, 84% and 100% concordance.

Regarding CLS® stems, at +/- 1 size, we did not find any significant

difference between the participants (OS, OR and DM) with respectively 86%, 80% and 97% concordance.

Regarding MS-30® stems, at +/- 1 size, we did not find any significant

difference between the participants (OS, OR and DM) with respectively 95%, 95% and 100% concordance.

Interobserver comparison for the cup size (planned/implanted).

OS OR DM

Pinnacle®

Exact Size 47% 54% 57% OS/OR P=0,082

+/- 1 Size 94% 96% 93% OS/DM P=0,347

+/- 2 Sizes 100% 99% 100% OR/DM P=0,261

Allofit®

Exact Size 46% 42% 79% OS/OR P=0,607

+/- 1 Size 85% 84% 100% OS/DM P=0,506

+/- 2 Sizes 94% 96% 100% OR/DM P=0,923 Interobserver comparison for the stem size (planned/implanted).

OS OR DM

Corail®

Exact Size 46% 47% 56% OS/OR P=0,343

+/- 1 Size 88% 90% 90% OS/DM P=0,526

+/- 2 Sizes 100% 99% 100% OR/DM P=0,439

CLS®

Exact Size 41% 34% 78% OS/OR P=0,990

+/- 1 Size 86% 76% 97% OS/DM P=0,537

+/- 2 Sizes 93% 95% 100% OR/DM P=0,971

MS-30®

Exact Size 61% 49% 88% OS/OR P=0,091

+/- 1 Size 95% 95% 100% OS/DM P=0,561

+/- 2 Sizes 100% 100% 100% OR/DM P=0,247

Conclusions

Regarding the interobserver comparison, we did not show any significant difference in terms of planned cups and stems compared to the prostheses truly implanted up to a variation of +/- 1 size. The implant desing had no negative influence on the templating accuracy whatever the planner involved.

Our preoperative templating was accurate in predicting the required implant size and results were similar to those available in the literature. Although the planning of a total hip arthroplasty should preferably be performed by the surgeon in charge, we concluded that this essential part of the planning procedure can also be performed by an orthopedic resident or a data manager who has anatomical knowledge.

84 85 89 80 56 100 95 85 100 0 10 20 30 40 50 60 70 80 90 100 OS OR DM Corail CLS MS-30

Respect of stem type (CCD angle) (planned/implanted) in percent.

tthirion@chuliege.be Virtual EFORT Congress

28-30 October 2020

Références

Documents relatifs

Methods A CT scan-based modelling and analysis system was used to examine the lower limb of 233 patients (102 males, 131 women; mean age 61.2 ± 15.2 years, mean body mass index 24.9

Section 3 presents the results, which include instantaneous velocity fields, velocity profiles from time and phase averages along the minor and major axes, the volumetric

planners’ background, the computer-based tools they used in work, their knowledge and experience of smart cities, and their opinions on how smart cities might

Keywords : polynomials with several variables, absolute factorization, symbolic-numeric algo- rithm, symbolic algorithm, LLL,

The unitary maps ϕ 12 will be very useful in the study of the diagonal action of U(2) on triples of Lagrangian subspaces of C 2 (see section 3).. 2.4

Using the standard norm, calculate the distance of the point (1, 2, 3) to P.. Calculate the Fourier coefficients

It shows that PhD students contribute to about a third of the publication output of the province, with doctoral students in the natural and medical sciences being present in a

STUDY THE EFFECTS OF THREE FACTORS ON THE OUTLET TEMPERATURE OF THE GEOTHERMAL DOUBLE U-TUBE